Web Analytics Made Easy - StatCounter

Lt Overhead Line Repair Tenders

Get complete information related to latest Lt Overhead Line Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Overhead Line Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Overhead Line Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :43131809 Due date: 17 Dec, 202517 Dec, 2025 2.97 Lacs
Tender For e tendering on partial turnkey basis for re strengthening of 11kv feeder no barotiwala 8 and 2 emanating from 132 66 11kv s stn jharmajri and strengthening of lt line in village sheran in electrical section mandhala uesd hpsebl barotiwala

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim

State Government

CTN :43133777 Due date: 16 Dec, 202516 Dec, 2025 NA
Tender For lowering and lifting of submersible pump sets along with all allied electrical and mechanical accessories for various tubewells under civil line ward in ac-20

State Government

CTN :43035629 Due date: 13 Dec, 202513 Dec, 2025 1.79 Lacs
Tender For corrigendum : tender for augmentation of existing 22/0.4kv, 25kva into 63kva s/stn. at durfuk alongwith conversion of 1-phase to 3-phase lt line in electrical section sunnam, under electrical sub division, hpsebl, pooh.

State Government

CTN :43092921 Due date: 16 Dec, 202516 Dec, 2025 5.87 Lacs
Tender For stringing of ht line from panamkuruthottam tfr to beena tfr via forest - beena ab to li kaprikad under electrical section koovapady

Central Government/Public Sector

CTN :43134374 Due date: 05 Jan, 202605 Jan, 2026 NA
Tender For modification of electrical lt and ht lines and supply arrangements in connection with wr-bpq 4th line work of ngp division c.rly

State Government

CTN :43122894 Due date: 15 Dec, 202515 Dec, 2025 4.95 Lacs
Tender For supply of routine maintenance items- crimping type non-insulated copper pin type terminal end 25 sq.mm , crimping type non-insulated copper pin type terminal end 35 sq.mm , crimping type non-insulated copper pin type terminal end 50 sq.mm , 300 sqmm crimping alluminium type in-line connectors , 240 sq mm crimping type alluminium in-line connector , 185 sqmm crimping alluminium , type in-line connectors cat no :hai-11 hex make , aluminium tube terminals 185.0 mm2, m10 , aluminium in line connector 70 mm2 , aluminium in line connector120 mm2 , 35mm alluminium in line connector als-2 dowell" , heat shrinkable sleeve for lighting wiring , heat shrinkable sleeve, size:45mm/18mm(for 240/300 sq.mm )for 11 kv , 1.1 kv busbar/cable couductor protection heat shrinkable sleeve diabefore shrink: 50 mm dia. after shrink: 16 mm for 1.1 kv lt cable , double pole mcb-2a , mcb/dp, 6a , indication lamp , mcb dp 16a ac, c-curve, csmbs2c16 , mcb dp 10a ac, c-curve csmbs2c10 , gls lamp 500 w screw type , plastic dori (sutari) for binding of plastic 0.5 thick &2mm width. , to make panelspare handle cssdf200a-400amp (cswh 145 s 12) , thinner for enamel paint. (tin of 1 ltr.) , multi functional fluid spray oks-601 , carbon cleaner spray , painting brush size 3" (75 mm) , painting brush size-38 mm , wire brush size 12" with wooden handle , washing powder (1 kg pack) , pvc buckets-15ltr , schneider , telemechanique/merlin gerin , make-push button for 22.5 panel , cutout with contact , elementtype of contact , :nocolour: yellowreferance , no.:xb5-aa51ntype:spring return , push buttons , oks 2621 safe l.c. spray, contact cleaner spray for live circuits 500 ml spray bottel) , flat cable 3 corex4 sqmm with copper conductor for submersible motor , pvc insulated, unsheathed flexible copper cable size 1 core x 2.5 sq. mm, 1100 v grade , auxiliary relay re-300 coil voltage 250v dc , jyoti make re-300 plug in type , relay, coil voltage 240 v,50hz ac with led indication & 4 change over contact having 10 amp rating. , tubular spanner set (8 pcs) , product no ts 08 taparia make , bimetal mini hole saw cutter complete with arbor, product no- hsm 12, size-12 mm , bimetal mini hole saw cutter complete with arbor, product no- hsm 19, size-19 mm , bimetal mini hole saw cutter complete with arbor, product no- hsm 22, size-22 mm , oil barrel hand pump , electrical hand blower 800 watt, 230 volt, 50hz , hand grinder machine. , #w963 play safe high voltage tape (25 mm x 0.76 mm x 9.1 mtr) roll , w963 play safe high voltage tape (50 mm x 0.76 mm x 9.1 mtr) roll , control transformer, 440v/240v, 250va , on/off selector switch, model: s16-61002-803, ac23a-10hp make: , salzer , on/off selector switch, model: s6-61002-b13, ac21a-440v-6a make: salzer , voltmeter selector , switch, model: s10-61100-b13, ac23a-4hp, 440v ac make: salzer , bus selection selector , switch, model: s6-61038-b13, ac23a - 3 hp make: salzer , voltmeter selector switch, 6a-vss-b13, ac21a, 440v, 6a make: salzer , local/remote selector switch, model: d16-61040-863 3.16a, dc22a, l/r-2 m.sec, make: salzer , ammeter selector switch part code-6a-s6-61325-b13-tdyr make-salzer , stanvac pen oil rust remover 6030,500 ml/pac , control transformer pri:0-375.5-415v 50hz blk-blu-brn sec:18v, 1.2a blu-blu 24v,3.2a brn-brn sheild:yel/grn burden 100va, 1ph , petroleum jelly 1kg pouch packing , safety solvent co2 contact cleaner. , #901 easyclean (nf) 500 ml. spray canon line electrical contact cleaner.

corporations/Associations/Others

CTN :43115063 Due date: 23 Dec, 202523 Dec, 2025 8.00 Lacs
Tender For rate contract for erection ,maintenance and dismantlying of electrical networks (oh line &cable) including ss maintenance in anna nagar subdivision of anna nagar division

corporations/Associations/Others

CTN :43130253 Due date: 05 Jan, 202605 Jan, 2026 37.21 Lacs
Tender For miscellaneous electrical maintenance works such as erection repair of pole plinth stay wire laying guarding of ht lt line conductor transformer building earthing tpmo la fuse unit installation lt panel busbar brick soling etc. works of cemd atp anpar

Central Government/Public Sector

CTN :43130952 Due date: 20 Dec, 202520 Dec, 2025 5.05 Lacs
Tender For providing of custom bid for services - extension of 440 v overhead line and installation of electrical switching devices for operation of static foggers installed at mkd-iii ocm
 Loading, Please wait...

Connect us via What's Up