Web Analytics Made Easy - StatCounter

Lt Power Panel Tenders

Get complete information related to latest Lt Power Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt Power Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt Power Panel Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39083645 Due date: 18 Mar, 202518 Mar, 2025 NA
Tender For corrigendum : supply of b7b1x59708 local control station haldia petro chemicals mca1094

CTN :39173674 Due date: 17 Mar, 202517 Mar, 2025 68.44 Lacs
Tender For corrigendum : supply, installation, testing, and commissioning (etc) of control desk, vfd panel along with motors for travel, local control station (lcs), junction box, and 6.6 kv ht panel with vcb for stacker reclaimer no. 1 at kstps kota against tn-19063

Central Government And Public Sector

CTN :39112820 Due date: 20 Mar, 202520 Mar, 2025 NA
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.

CTN :39310425 Due date: 17 Mar, 202517 Mar, 2025 68.44 Lacs
Tender For corrigendum : tn-19063 supply, installation, testing and commissioning (etc) of control desk, vfd panel along with motors for travel, local control station (lcs), junction box, and 6.6 kv ht panel with vcb for stacker reclaimer no.1 at kstps, kota.

CTN :39542114 Due date: 24 Mar, 202524 Mar, 2025 NA
Tender For tender for supply of spare auxiliary relays and other switchgear components for kailaras compressor station - arelay, mtr protect, mpr300, 1-2.75a set , motor protection relay, 2 to 5.5a , mpr300 relay,4-11 amp,l and t make , motor protection relay, 8 to 22a , motor protection relay, 16 to 44a , motor protection relay, 32 to 88a , relay, motor protect, mm10, 110-240v aux , mpcb, 6.3a-10a, ms116-10, abb , mpcb, 9a-12.5a, ms325-12.5, abb , relay ltmr 100 mfm tesys-t,telemecanique , under voltage relay, vag11yf8016hch, ge , relay, master trip, pq8nch2j, 220vdc aux , relay, master trip, pq8nch2j, 24v dc aux , fuse fwp-150b ,35a, 700 vac dc , fuse fwp-60b ,35a, 700 vac dc , fuse fwp-35b ,35a, 700 vac dc , control fuse, 600v , fnm 1 1 8 , contactor lc1f400 400a 240v schneider , switch,400a,fn400,l and t , sfu,125a,fn125,l and t , sfu,63a,tp,415v,fn-63l and t , sfu fn1000h sd tpn, sb90744 , miniature current circuit breaker, 100a , sfu, 20a, tpn. 3kl8111-3ha00, siemens , change over switch , moulded case circuit breaker,250a, l and t , mccb 3vt1716 siemens 160a 4pole 415v ac , sfu nx032tpndi 32a tpn 1no1nc schneider , sfu nx063tpndi 63a tpn 1no1nc schneider , sfu nx125tpnd 125a tpn 1no1nc schneider , molded case circuit breaker,250a,36ka,3p , moulded case circuit breaker, dh100,3p,63a , moulded case circuit breaker, dh125,3p,125a , moulded case circuit breaker, dn3-630n, 3p,630a , moulded case circuit breaker, dn0-100m, 3p,63a , moulded case circuit breaker, dn1-160m, 3p, 125a , moulded case circuit breaker, dn2-250d, 3p, 250a , switch,tnc,20a,660vac dc,alstom , switch,selector,20a,660vac dc,alstom , surge protection device 280vdc citel , phase seq meter,psi 96m,ae , test terminal block for energy meter connections , mashrum head key lock pb,dia 22mm,head 40mm,2no 2nc,red , local remote,switron,16a dc , digital multifunction energy meter with lcd display , cooling fan ,6 inch , cooling fan, 12 inch , ammeter,0-200,mc,96x96 , voltmeter, dc 0 - 400 v, mc,96x96 , controller, apfc, eta smart 14r, 415v , controller, apfc, br 6000-r12, 415v , controller, temp, sz-7510-p-di, 230v

CTN :39539694 Due date: 11 Mar, 202511 Mar, 2025 NA
Tender For ichp- removal of carbon dust scale deposition on the electrical internal components and tightness checking of contactors in control desk at ss-iii, cleaning of pull chord switches, zero speed switches, siren & local remote switches and intermediate panel, 10 kva ups equipments related to station `a' conveyor system.

Central Government And Public Sector

CTN :39530195 Due date: 17 Mar, 202517 Mar, 2025 14.94 Lacs
Tender For repair work of control room and security barrack in the power house of chutak power station, kargil (work reserved for project affected families (pafs) and local bidders from district kargil).
 Loading, Please wait...