Web Analytics Made Easy - StatCounter

Lt System Repair Tenders

Get complete information related to latest Lt System Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Lt System Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Lt System Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39437171 Due date: 13 Mar, 202513 Mar, 2025 NA
Tender For special repair/replacement of lt ug cable and rising of lt panels, provn of deficient electric meter, dbs, submain wiring and provn of pipe line under ge (army) baroda.

CTN :39430949 Due date: 13 Mar, 202513 Mar, 2025 NA
Tender For supply of telephone set line lead , telephone handset lead , electric board 60 amp , 16 amp 3 pin plug , 2.55mm wire

CTN :39436085 Due date: 15 Mar, 202515 Mar, 2025 28.29 Lacs
Tender For ked/112 of 2024-25 dated 21.02.2025 for creation of 02nos. 100kva sub stations alongwith ht/lt line at dhar koti stage-i and ii under nabard phe in respect of jpdcl electric sub division billawar of electric division kathua on turnkey basis

CTN :39388302 Due date: 11 Mar, 202511 Mar, 2025 NA
Tender For fixing of annual rates for supply of line material for ht/lt works as per rec/is/pdd approved standard and rec drawings under the jurisdiction of jpdcl electric div-i, parade, jammu for the financial year 2025-26

CTN :39407206 Due date: 01 Mar, 202501 Mar, 2025 3.02 Lacs
Tender For repair/maintenance of 3.3kv oh line of kargali washery feeder feeding power to area quality lab with repairing of 2 nos gang switch from mrss kargali to electric section at kargali washery under bnk area.

CTN :39270108 Due date: 28 Feb, 202528 Feb, 2025 91.72 Lacs
Tender For corrigendum : equipments for ece department under pm-usha for mbm university, jodhpur. ubn no. mbm2425glob00097 - 400 mhz to 4.4 ghz software radio setup (3 qty.) (full details and specifications as per tender document), biometric and biomedical test setup (2 qty.) (full details and specifications as per tender document), versatile simulator for embedded and control system design (2 qty.) (full details and specifications as per tender document), lan simulator software training setup (3 qty.) (full details and specifications as per tender document), handheld spectrum analyser (1 qty.) (full details and specifications as per tender document), pc hardware technology trainer (4 qty.) (full details and specifications as per tender document), bluetooth, rfid, barcode technology trainers (4 qty.) (full details and specifications as per tender document), rf field strength analyser and power meter (2 qty.) (full details and specifications as per tender document), hd led tv, cctv technology trainers (4 qty.) (full details and specifications as per tender document), ups and smps trainer systems (4 qty.) (full details and specifications as per tender document), iot robotics and wireless sensor network trainers and test setups (2 qty.) (full details and specifications as per tender document), networking simulation platform (1 qty.) (full details and specifications as per tender document), gps development kit (4 qty.) (full details and specifications as per tender document), electric power transmission line trainers (2 qty.) (full details and specifications as per tender document), mobile telephony communication 4g/5g trainer and development system (2 qty.) (full details and specifications as per tender document), hydraulic and pneumatic control system trainer kit (2 qty.) (full details and specifications as per tender document), embedded learning stations for latest arm series microprocessors (02 qty.) (full details and specifications as per tender document)

Central Government And Public Sector

CTN :39403367 Due date: 06 Mar, 202506 Mar, 2025 12.27 Lacs
Tender For supply of three phase electric motor as per atc doc , pump element for dual line grease pump dlgp 50 08 for miv assy item no 5 drg no dlgp 50 08 338 , reduction gear box,type-a237, ratio 70 by 1, ,item no-6, drg no- dlgp-50-08-338797 , direction control valve,model- 4we01 j 33 c w230 n9k4, item no-12,drg no-dlgp-50- 08-338797 , direct operated pressure relief valve,model-dprh06t315-11 11by09, item no-11,drg no-dlgp-50-08-338797 , coupling, item no-3,model-l 095,drg no-dlgp-50-08-338797 , dose feeder, model- dw-43, drg no-dlgp-50-08-338797 , straight connector 12 odx3by8 bsp ,item no-16,drg no-dlgp- 50-08-338797 , pressure gauge ,100mm dial,range- 400kg per cm2,for end pressure relay,drg no-dlgp- 50-08-338797 , dose feeder, model- dw-44, drg no- dlgp-100-08-338796 , ball valve 18 odx1by2 bsp, 500 bar,drg no-dlgp-100-08-338796 , straight union 10 od x1by4 bsp, item no-16,drg no-dlgp-100-08-338796 , ferrule 10 mm, item no.12, drg no. dlgp-100-08- 338409 , ferrule 18 mm, item no.12, drg no. dlgp-100- 08-338409 , ferrule 8 mm, item no. 12 , drg no-dlgp- 50-08-338410 , ferrule12 mm, item no. 12 , drg no- dlgp-50-08-338410 , control panel , grease gun pump

Central Government/Public Sector

CTN :39065214 Due date: 27 Feb, 202527 Feb, 2025 33.00 Lacs
Tender For corrigendum : repair/maint of pumping system, switchgear, pipe line and valves at jne area and external electric supply, external water supply and allied works under ge (utilities) udhampur

Central Government/Public Sector

CTN :39171113 Due date: 03 Mar, 202503 Mar, 2025 1.80 Crore
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene

Central Government/Public Sector

CTN :39361302 Due date: 08 Mar, 202508 Mar, 2025 30.00 Lacs
Tender For repair maint of solar water heaters electric panels connected pipe line cables and connected items at akhnoor under ge (north) akhnoor
 Loading, Please wait...

Connect us via What's Up