Get complete information related to latest Matching Transformer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Matching Transformer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Matching Transformer Tenders.
Tender For supply of emi emc filter 3a 2phase 415 v acef 2ao refer technical specification sr no 10 , control transformer 415v 230v ac 300va k refer technical specification sr no 20 , voltage monitoring relay 7ug0 818 siemen refer technical specification sr no30 , motor protection realy s2 wtr1 minilec e refer technical specification sr no 40 , mcb tp 2a c curve 5sl63o27rc siemens t refer technical specification sr no 50 , mcb sp 2a c curve 5sl61o27rc siemens t refer technical specification sr no 60 , 7 amp power contactor coil 230vac 3rt2o1 refer technical specification sr no 70 , motor protection realy mpr 3 x 1 2 7 am refer technical specification sr no 80 , emergency stop pb with inc xb5 as542n sc refer technical specification sr no 90 , 3pos spring return selector swith 2no refer technical specification sr no 100 , lamp led type red 230v ac xb7-ev04mpn sc refer technical specification sr no 110 , control realy 4c o 23ovac with base rxm4 refer technical specification sr no 120 , d xr limit switches 3se525o obco5 sieme refer technical specification sr no 130 , panel light 5w led 61010philips tag tl1 refer technical specification sr no 140 , thermostate 230 v ac 205c girish ego ta refer technical specification sr no 150 , bottle screw eye bolt refer technical specification sr no 160 , bottle screw body refer technical specification sr no 170 , hook refer technical specification sr no 180
Tender For corrigendum : e-tender for rate contract for supply of electrical items - closing release,uc release - ,universal motor for breaker spring charge ,shunt release,l.a.f.a.p ,for castell lock: u-power,micro switch for spring charging, led a meter, led a meter, led volt meter, maximum demand controller ,phase loss + phase sequence (smr), aux. contactor with ac coil , aux. contactor with ac coil, emergency stop button,modular , no contact block,selector switch,white led indicating lamp ,blue led indicating lamp ,green led indicating lamp, yellow led indicating lamp ,amber led indicating lamp ,red led indicating lamp ,white led indicating lamp, blue led indicating lamp ,green led indicating lamp, yellow led indicating lamp ,amber led indicating lamp ,red led indicating lamp ,hotter, 230v ac,neutral link,control terminals,1pole ac instantaneous high stability circulating current relay ,micro processor based release,acc spreader terminal,aux contact, extended rotary handle,microprocessor based released ,acc spreader terminal,microprocessor based released ,acc spreader terminal , mccb with ti release,microprocessor based released ,aux contactor with dc coil,timer,mccb with mp based release ,extended rotary handle for above mccb,panel door mounted key lock for extended rotary handle,ct shorting terminals,potential transformer,power contactor,add-on block ,green, flush head button with, 1no,red, flush head button with, 1nc,modular , no contact block,modular , nc contact block,mccb,spreader terminals ,power contactor,,power contactor, red mushroom head for emergency stop,power contactor,apfc capacitor,reactor, thyristor module switch, semi-conductor protection high speed fuse,cylindrical type capacitor, copper reactor ,thyristor switching module, apfc capacitor,detuned copper reactor ,semi-conductor protection, heavy duty, cylindrical type capacitor,detuned copper reactor,thyristor switching module,semi-conductor protection ,cylindrical type capacitor,battery charger with float and boost mode,electrical panel ventilation fan ,electrical panel ventilation fan,electrical panel ventilation fan,electrical panel ventilation fan,electrical panel ventilation fan,electrical panel ventilation fan,electrical panel ventilation fan,electrical panel ventilation fan,rubber ht insulation tape ,12 kv,19mm ,water resistance insulation tape,electrical insulation tape-red,green,yellow,black,blue,electrical panel heater,electrical panel heater,relay module with base ,relay module with base ,relay module with base ,relay module with base ,tnc switch,tnc switch, start button with led , stop button with led ,voltage monitoring relay ,current transformer,current transformer,current transformer,current transformer,current transformer, current transformer,current transformer,current transformer,current transformer,earth leakage relay,sitc of amf dg panel display,add-on contactor
Tender For supply of brass cable gland complete with ci clamp stud , auxiliary switch for vaccum contactor 2no 2nc , auxiliary contactor 3no 1nc 110v coil , el unit complete without transformer , pt 40va 0 to 8v to 12v , 0 to 110v , transformer panel fitted with 25amps contactor complete , 16 amps contactor with 110v coil , 25 amps contactor with 110v coil , thermal overload relay , 25amps rev isolator with handle , incoming throughgoing dmc moulded terminal with brass stud complete , pilot relay 12v dc , pilot relay 12v ac , socket housing with dmc insulator and brass pin contact , plug housing with dmc insulator and brass pin contact , c i incoming cable sealing box , interconnecting dmc moulded terminal with brass stud complete , c i terminal chamber for incoming and throughgoing side , ci cable sealing box for incoming and throughgoing side , blanking cover plate for throughgoing side , brass gland with stud and nut
Tender For supply of m2 5970 002187 insulator disc bakelite 46.5mm oa dia 0.5 mm thik with 3 holes , m2 5935 004522 connector free electrical metal clad male contacts 2pole 88mm oa lg 31 mm oa dia , m2 5945 001642 coil solenoid 30 ohms 1500 turns epoxy plastic moulded 39.5mm oa dia 24 mm lg. , m2 5950 006312 transformer power step down 220 volts 50 hz input with multiple output encapsulated in epoxy resin , m2 5975 001419 conduit assy metal rigid steel seamless tube 10mm id 12mm o d boforse 4023989 complete with end fittings. , m2 6625 003407 mount indicator tail light 40mm aa l 70 gun , m2 5930 003688 switch box battery mains eeum , m2 5930 004253 switch box micro switch assembly lh for 40 mm aa l70 gun , m2 5975 001403 conduit assy metal rigid steel seamless tube 10mm i d 12mm o d bofors 4025394 complete with end fittings. , m2 5975 001413 conduit assy metal rigid steel seamless tube 10mm i d 12 mm o d bofors 6128613 complete with end fittings. , m2 5975 001415 conduit assy metal rigid steel seamless tube 10mm i d 12 mm o d bofors 6128615 complete with end fittings. , m2 5975 001420 conduit assy metal rigid steel seamless tube 10mm i d 12 mm o d bofors 4023990 complete with end fittings. , m2 1010 002683 panel light rear assembly 40mm aa l70 gun , m2 4540 000088 heater immersion electric with thermostate control 40 mm aa l70 gun assembly 220v 50 hz 500w , m2 5307 003475 stud plain steel 28 mm long threaded m5 for 12mm and 10 mm at ends , m2 5330 012583 ring sealing torroidal synthetic rubber 43 mm i d 1.6 mm thick , m2 6350 000102 horn electrical 220v ac 50hz 40mm aa l70 gun eeum , m2 bof 6118806 pin , m2 bof 61491902 plunger , m2 bof 61491903 plunger , m2 bof 6181510 sign for box distribution gun , m2 5940 002185 turminal box 40mm aa l70 gun electrical equipment upper mounting , m2 5325 000789 strapping steel mild steel annealed zinc coated 5mm wide 05.5mm thik , m2 5365 006414 spacer plate steel 90x41x12mm o a size with two fixing holes , m2 5935 004519 plug and socket assembly electrical special purpose coil light assembly , m2 5975 001383 cable gland assy brass threaded m18x1.5 cable in let hole dia 10.5 mm , m2 5975 001391 cable gland assy brass threaded m18x1.5 cable in let hole dia 12 mm , m2 5340 009157 trap retaining steel 28 mm x 15mm oa dimention , m2 5355 001685 knob steel parkerised 5 mm shaft dia. 43x21x12 mm o a size , m2 5930 003690 switch sub assembly gun main motor stop switch , m2 5930 004252 switch box micro switch assembly rh for 40 mm aa l70 gun , m2 5935 004520 connector fixed electrical assembly 4 male contacts c w protection cover and chain , m2 5950 006314 inductor audio frequency 1.1 h at 1kc s 1 volt working voltage 220 volts ac 50 hz current rating 0.5 amps dc resistance 6.5 ohms 5 , m2 5999 004727 armature relay arm breaker gun electro magnet assembly , m2 6130 000398 power supply box control local power for 40 mm aa l70 gun , m2 6150 000380 battery box with on off switch assembly 40 mm aa l70 gun electrical equipt upper mounting , m2 5930003687 switch box lighting on off eeum
Tender For supply of installation of damaged spare parts of plc and scada system - control transformer 1kva , motor protection cuircuit breaker, range- 51 -70a , breaker handle with knob, siemens 3vt series , panel door lock for power pack , ethrnet switch 5-port unmanaged, ports- 5 unmanged type aux. supply- 24vdc , smps din rail mounted 24v dc 10a, output- 24v dc, 10a din rail mounted type , star delta timer, 0 -60 sec , panel fan, 220v ac, size 6 inch , mcb 2.0 amp. single pole , mcb 4 a single pole , single pole mcb 6 amp , mcb 4 a double pole , dc mcb double pole 220 v dc 06 amp , tripple pole mcb 4a, c04 , mcb tripple pole, c curve, 6amp , relay 8-pin with base, 8-pin 24v dc with base , space heater, rating-500w 230v ac , pressure gauge, analog type, range- 0-500kgf per sq. cm , tank oil gauge, tank mounted direct measuring , directional solenoid valve, operating pressure- 315 kgf per sq. cm coil voltage-24v dc , gate position sensor for radial gate, e1-type range 0- 360 degree, analog output 4 - 20 ma , indication light - blue, indication lamp 22.5 mm 220v ac blue , differential pressure transmitter, two wire 4 -20 ma dc output with hart , level transmitter accuracy 5-10 mm , gate position indicator 5 digit 0.56 inch display 21 , voltmeter 0- 500v - analog , push button red with nc add on , ammeter, 0 -250a analog , indication light - red, indication lamp 22.5mm 220vac red , indication light - yellow, indication lamp 22.5mm 220v ac yellow , indication light - green, indication lamp 22.5mm 220v ac green , jumbo display size 6.5 inch usb ports 2.0 x 1, 3.0 x 1 , push button yellow with no add on, size 22.5 mm , push button blue with no add on, size 22.5 mm , push button green with no add on, size 22.5 mm , push button black with no add on, size 22.5 mm , emergency push button, size 22.5 mm , phase preventer relay system ac mode auto , utp cable cat-5e , cable 1.5 sqmm 4c flexible 100m bundle , 1024 tags and ddls of scada system , control terminal block, 2.5sq.mm , service engineer charges , traveling charges , freight charges
Tender For corrigendum : tender invited for (1) design, supply, installation, retrofitting, testing and commissioning of 220kv bus bar panel/scheme, 220kv bus coupler scheme and 400/220/33kv ict and station transformer-1 to 4 relay scheme at wanakbori tps. & (2) design, supply, installation, testing and commissioning of numerical bus bar protection scheme for 132kv at dhuvaran gbps.
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica