Tender For supply of repair of vehicle - material and labour for carrying out servicing as per manufacturer instruction of maruti gypsy ba no 14b - 113619l from its authorized service station , seat cover for maruti gypsy -01 set , replacement of side view mirror -01 nos , carrying out necessary greasing in hub of wheel , repair of self starter to provide proper supply to alternator- 01 job , replacemnt of split pin 3.2 x14 -04 no , replacement of fuel filter, oil filter, air filter, water separator-04 set , replacement of hand break-01 nos , replacement of side view mirror -02 nos , replacement of wheel bearing -05 set , replacement of wheel cap -02 set , replacement of break disc-04 set , replacement of sound horn -01nos , replacement of fan belt -02 nos , repair steering gear box left side steering hard -01 job , carrying out wheel alignment as per manufacturer instruction , replacement of hub greasing kit spicer front -01 no , carryout necessary greasing in spring leaf , replacement of tail lamp-01 set , calibration of fuel injection pump and cleaning of nozzel -01 job , replacement of coolant as per manufacturer instruction , repair of body door-04 nos , replacement of foot matting-01set , carry out minor denting and panting , replacement of break pad front -04 no , replacement of head light lamp -01 set , replacement of engine oil 20w 40 as per manufacturer instruction
Tender For providing of repair and overhauling service - 4362 calibration of laboratory equipment and glassware with anticipatory consumable spares; laboratory equipment and glassware with anticipatory consumable spares; yes; buyer premises
Tender For providing of calibration services - medical; medical device calibration; nabl labs, any other government approved labs / service provider; buyer premises (onsite)
Tender For providing of calibration services - particle count machine; pamas s 40 particle count machine; nabl labs, national testing house, any other government approved labs / service provider, naval science & technological laboratory(nstl), drdo facilities, research desi..
Tender For providing of calibration services - calibration of particle counter parker make; calibration of particle counter parker make; any other government approved labs / service provider; buyer premises (onsite)
Tender For state plan 2023-24 supply and installation of equipments in effluent testing lab at pathanamthitta - appendix - a, od199678/2023-2024:supply and installation of uv visible double beam spectro photo meter for etp lab with the following specifications such as optics : double beam mode of operation : instrument can operate standalone and pc based wavelength:190-1100nm wavelength accuracy : 0 .5nm wavelength resolution : 0.1nm spectral bandwidth :1nm absorbance range :-4 abs to 4abs absorbance accuracy :0.005 at 1abs photometric repeatability: 0.002 abs at 1 abs display: 10 inch with 1200 x 800 resolution with touch screen sample holder: 5 position automatic sample holder and one for reference. stray light :?0.1% t at 220nm and 340 nm mode of operation: single wavelength, multi wavelength, scan, time scan, dna & protein measuring mode : %t, abs, concentration, nitrate analysis and fluoride analysis source :tungsten halogen lamp and deuterium lamp printer : should support all type of printers memory : 128gb software should have audit trial functionality. accessories: 1 pair quartz cuvette, pc controlling software warranty : 1 year amc : 2 year oem should have service center in kerala bidder should submit minimum 5 performance certificate of different users in kerala for the quoted model. should provide nabl calibration certificate should provide iq, oq and pq documentation , od199643/2023-2024:supply and installation of micro controller based turbidity meter having the following specifications:- ranges:0.05-1000 ntu in 4 ranges (automatic) 0.05-1 ntu 0.1-10 ntu 8-100 ntu 50-1000 ntu accuracy : 1.5% of fsd in 0-500 ntu ? 2% of fsd in 500-1000 ntu repeatability : 1% of fs (std.) source : led detector : photodiode display : 2 line 16 ch.lcd calibration : 1, 10, 100, 500 &users selectable values data storage : calibration & data stored in memory printer port : epson compatible 80 column dot matrix power : 230 volts 10%, 50 hz accessories : flat bottom test tubes (25mm ) ? 4 nos. & light shield warranty : 1 year amc : 2 year oem should have service center in kerala bidder should submit minimum 5 performance certificate of different users in kerala for the quoted model., od199680/2023-2024:supply and installation of micro controller based ph meter with 3 point calibration for etp lab with the following specification such as ph : range :1 to 14 ph resolution :0.01ph stability : 0.01ph per hour relative accuracy : 0.02ph 1digit slope : 85% to 115% standard buffers : 7 .000, 4 .000 ,9.183 ph buffer deviation : 0.2ph mv range : 0 to 1999.9mv resolution : 0.1mv accuracy : 1 mv 1 digit temperature compensation : auto/manual range : 10c to 99.9c resolution : 0.1c accuracy :0.5c 1 digit display : 7 segment 7 digit led warranty : 1 year amc : 2 year oem should have service center in kerala bidder should submit minimum 5 performance certificate of different users in kerala for the quoted model., od199679/2023-2024:supply and installation of micro controller based conductivity - tds meter with cells and temperature prob. having the following specifications:- conductivity : range : 0.1s to 200ms(6 decadic ranges) resolution : 0.001s accuracy : 1% of f.s. 1digit tds range : 0.1ppm to 200ppt.(6 decadic ranges) accuracy : 1% of f.s. 1digit temperature range : 0 c to 100c (auto/manual) resolution : 0.1c accuracy : 0.2c 1 digit cell constant : acceptable from 0.1 to 5.0 auto temp. compensation : 0 c to 100c with pt 100 sensor display : 7 digits, 7 segment leds (3 digits for temp/tempco 4 digits for conductivity/tds) with automatic decimal point selection tds factor : 0.0 to 9.99 user selectable printer port : epson compatible 80 column dot matrix accessories : i)conductivity cells, cell constant 1.0 (2nos.) ii)temperature probe (pt-100 sensor) iii)stand & clamp warranty : 1 year amc : 2 year oem should have service center in kerala bidder should su
Tender For corrigendum : deputation of service engineer of ms siemens for servicing, calibration and testing of siemens make generator protection, bus-bar protection and lbb protection relays installed at 1x500mw unit, at sgtps, mppgcl, birsinghpur.