Get complete information related to latest Meter Sale Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meter Sale Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meter Sale Tenders.
Tender For corrigendum : design, supply, installation, commissioning, training of various type of equipments for esdm (electronic system design and manufacturing) of msme training centers located at greater noida, bengaluru, puducherry and idemi mumbai on turnkey basis - decade resistance box , ct/pt calibration system , multifunction calibrator , decade capacitance box , ct analyzer , standard resistors , standard weights (el class) , pippete calibration system , low temperature bath (-80 to ambient degree temperature) , frequency counter , energy meter test system (3 position) , precision temperature stabilised resistance standard (high) , decade inductor box , precision temperature stabilised resistance standard (low) , sound level calibrator , digital power analyser , decade resistance box (4 nos.) , process calibrator , hv divider , decade mega ohm box , standard weights (e2 class) , 6 and half dmm , temperature indicator , time interval meter , temperature indicator with compensation , standard weights (f1 class) , semi-micro balance (upto 200 gms) , tachometer calibrator , standard thermocouple (type s) without compensation , sound level analyzer , standard platinum resistance temperature (prt) detector , precision balance (upto 6.1 kg) , thermo-couple calibartion furnace (300 to 1100 degree temperature) , lcr bridge , humidity measurement probe , dry block calibrator (ambient to 600 degree temperature) , anechoic chamber with radiated susceptbility and radiated emission test system , alltitude test chamber , compact emc tester , environmental chamber , digital pressure controller (dead weight pressure tester) , line impedance stablizing network , harmonics/flicker measurement test system , impulse generator , rf shielded chamber , vibration plus environmental chamber , three phase regulated variable power source , humidity generator, relative humidity , bump/shock test system , heat deflection temperature test set , vibration test system , electronic load , conducted rf immunity simulator , rohs testing lab - inductively coupled plasma optical emission spectrometer (icp-oes) , thermal shock chamber , ac dc current source , ultra precision capacitance bridge , esd simulator , horizontaland verticlal flame chamber , rohs testing lab - energy dispersive x-ray fluorescence spectrometer (edxrf) , single phase regulated variable power source , precision energy standard , rohs testing lab - gas chromatograph mass spectrometer (gc-ms) , ingress of water test system - i set , rohs testing lab - ion- chromatograph (ic) , needle flametest chamber , salt spray chamber , dust chamber , digital storage oscilloscope , defibrillator proof test set , thermostat endurance test set , flexing test apparatus , electrical safety tester , winding resistance meter , temperature recorder , radiation meter , tracking test apparatus , gas detector , cord anchorage test set , digital multimeter (handheld/desktop) , glow wire test apparatus
Tender For supply of mains power control and isolation module - tabletop with mains power control and isolation module single phase mains power supply - ac power panel having as per attached specification. , variable dc power supply range- 0-300vdc/5a as per attached specification. , digital multimeter with eht probe as per attached specification. 26.00 , low range pressure calibrator range - (30g/100g/300g) as per attached specification. , high range pressure calibrator range- 0 to 150kg/cm2 as per attached specification. , voltage source as per attached specification. , variac (range- 0-270 vac/4a) as per attached specification , megger (100 - 500 vdc) as per attached specification. , temperature gun as per attached specification. , 50 mhz oscilloscope as per attached specification. , function generator as per attached specification. , clamp meter (range - 0-50ma) as per attached specification. , clamp meter (range - 1-10a) as per attached specification. , decade resistance box as per attached specification. , soldering & desoldering station as per attached specification. , digital pressure gauge range-(0 -100 bar/ - 1 to 7 bar) as per attached specification. , process calibrator with hart as per attached specification. , test lead sets as per attached specification. , adjustable table lamp with magnifying glass as per attached specification.
Tender For corrigendum : supply of lab equipment - details decription attach in the specfication document ), bench top single beam systronics uv spectrophotometer 340 999 model no 167 covers 190to 1100 nm 4 position cuvette holder automatic wavelength selection 128x64 graphical lcd printer interface usb computer interface with professional scanning software specifications wavelength range 190 1100nm spectral band width, remi cis 24 plus orbital shaking incubator size 580 by 600 mm shaking speed range 20 to 250 rpm voltage 220 240v external dimensions 800 x 1150 x 1300 mm chamber volume 215 ltrs, manual baby mini power pack manual bio world, mini horizontal gel electrophoresis system, advance rotary microtomy latest spencer 820 type with razer, compound microscope, laboratory hot air oven, laboratory eggs incubator capacity 80 lit, ph meter digital, conical flask 200 ml insufficient number available, electronic balance, gel electrophoresis assembly with digital power pack, thermal cycler, cooling centrifuge, gel documentation unit with computer, micropipette, tips of micropipette, eppendorf tubes, pcr tubes, deep freezer, laminar air flow, ph meter, soxhlet apparatus with heating mantle, autoclave, bottle top dispenser with dual inte technology, centrifuge, digital chemical balance, double door refrigerator, d o meter, digital ph meter with electrode lcd display, digital photoelectric colorimeter, digital potentiometer, distillation apparatus, dryer and temperature controller, blower, chemical thermometer, calorie meter, beaker 50ml 100ml 250ml 500ml and 1000ml catering to various volume crafted from high quality 3point3 borosilicate glass the low form design with a wide base and tapered spout, funnel, pipette, burette, burette stand, mortar pestel, electronic balance, burette brush, test tube brush, conical flask, volumetric flask capacity sg 100 100ml sg 250 250ml sg 500 500ml sg 1000 1 000mlmaterial glass heat resistance with graduation, wire gauze, round bottomed flask, periodic table poster, gas connection and fitting in new lab, water bath digital, digital ph meter, digital blood pressure machine, blower, single needle lock stitch sewing machine, over lock or inter lock sewing machine, usha steam ironpro s13816, notice board, inverter, water coller
Tender For corrigendum : procurement of different tools and plants for repairing of distribution transformers at different trws under sbpdcl - welding machine 450 amps , chain pully block 3 mt cap. , chain pully block 5 mt cap. , fire extinguisher 10kg (carbon dioxide) , fire extinguisher 10kg (foam type) , megger (hand driven) 5kv/5000m? , ratio meter (non-automatic) , winding resistance test meter , drill machine 1" , tripod 16? for lifting , electronic multimeter , electronic tongue tester , sling rope with d shakle ? diax7? length , sling rope with d shakle ? diax7? length , ms trolley (6?x3?size) mounted on 4 nos. iron wheel , high voltage testing machine , hydrolic hand pallet truck 3 mt , weighing machine capacity 1 ton , 52" table mounting hand operated press board cutting machine with all accessories , dpc strip covering machine single head
Tender For supply of non-contact high voltage detector (q3) , digital earth resistance meter (q3) , digital light meter (q3) , true rms clamp meter (q3) , digital multimeter (q3)
Tender For corrigendum : tender for supply of resistance temperature transmitter and indicator - resistance temperature transmitter ( resistance to current converter) , make -elektra precision .input- rtd pt-200. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-1.(bidder should comply one to one in specification as attached) , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd pt.200. temp range- 230 - 320 degree centigrade. o/p- 04 to 20 ma dc. single output. other common details as per attached annexure-1. , spare elektra ( earlier lektrolab ) make resistance temperature transmitter. input rtd-pt.200. temp range- 0-320 degree centigrade. output- 04 to 20 ma dc with double isolated outputs. other common details as per attached annexure-1. , resistance temperature transmitter ( resistance to current converter) , make-elektra precision .input- rtd pt-100. temperature range 0-100 degree centigrade , output- 04 to 20 ma dc (two no of output) zero & span adjustable. power supply- 118 vac with connector. other detail as annexure-2.(bidder should comply one to one in specification as attached) , indicating alarm meter , make - m/s elektra precision systems , tag-flow indicating alarm meter , range-0-400 ft/sec , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag-temperature indicating alarm meter , range-0-100 degree c , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- differential pressure indicating alarm , range- -15 to +25 gm/cm2 , alarm -high , alarm relay-one for high alarm , input -4-20ma , mounting arrangement-1a , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating alarm , range- 0-700 (squre root scale flow) lpm , alarm -low , alarm relay-one for low alarm , input -10-50ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- temperature indicating alarm , range- 0 to 70 degree c , alarm -low/high , alarm relay-one for high alarm and one for low alarm , input -4-20ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-6 (squre root scale) klpm , alarm -no alarm , alarm relay-no alarm , input -10-50 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- level indicating meter , range- 0-10 meter , alarm -no alarm , alarm relay-no alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- flow indicating meter , range- 0-10.7 meter / sec & 0-30 feet /sec , alarm -high , alarm relay-one for high alarm , input -0-4 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , indicating alarm meter , make - m/s elektra precision systems , tag- pressure indicating alarm meter , range- 0-0.7 kg/cm2 , alarm -high/low , alarm relay-one for high alarm & one for low alarm , input -4-20 ma , mounting arrangement-4b , normal operating 118 v ac , 50 hz +/-10 percent , i