Get complete information related to latest Meter Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Meter Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Meter Tester Tenders.
Tender For annual maintenance contract including supply of spares for fire fighting engines at wrpl chaksu - gst rate for item no. 3.0 to 10.0, amc ff engines- service items, amc (monthly maintenance charges): monthly maintenance charges for maintenance of fire fighting engines of greaves (model: tbd4i v 12 rc, 07 numbers) at iocl, chaksu pump station, deployment of required manpower, tools and tackles including personal protective equipment for the manpower deployed at site, testing equipment, all transportation,all labour etc., carrying out routine, preventive maintenance of equipment as per sound engineering, oem recommendations, operating and maintenance practices, and directions of eic. note: unit "mon" shall be treated as one month; monthly, quarterly, half yearly, yearly maintenance as per schedule of oem are to be carried under this item. (total 07 visits per month), minor breakdwon maintenance: attending minor breakdown in the engines on call basis. this item includes deployment of required manpower, tools and tackles including personal protective equipment for the manpower deployed at site, testing equipment, all transportation,all labour etc., to attend the breakdown problem within shortest duration. note: spares/ consummables etc if any will be provided by iocl; payment will be made on per engine per breakdown basis., repair & maintenance of radiator: dismantling, cleaning, inspection, repair & maintenance including arresting of coolant leakages, hydrotesting & reinstallation of radiators of fire fighting engines of greaves cotton make (model: tbd4i v 12 rc) including all tools & tackles, machining etc. complete in all respect as per direction of eic/site engineer.note: payment will be made on per radiator basis., calibration of fuel injectors of diesel engine of greaves cotton (model tbd4iv12) from authorized workshop inclusive of consumables, labour charges, transportation etc. as per direction of eic/site engineer., overhauling & calibration of fuel injection pump (fip) of diesel engine of greaves cotton (model tbd4iv12) from authorized workshop inclusive of consumables, labour charges, transportation etc. as per direction of eic/site engineer., major overhauling of diesel engine of greaves cotton (model tbd4iv12) including dismantling of engine parts like fuel injectors, cylinder heads, fuel injection pump, piston-cr assembly, liners, turbochargers, main bearings, lube oil pump, cooling water pump etc. cleaning & refitting/replacement of faulty engine parts as per direction of eic/site engineer. required spares shall be supplied by iocl.note: load trial of the engine to be carried out for 04 hours prior to handing over the engine, repairing & reconditioning of cylinder head of diesel engine of greaves cotton (model tbd4iv12) including replacement of faulty parts like valves, valve sheets, valve guides, springs etc. work includes labour charges, transportation etc. complete in all respect as per direction of eic/site engineer., gst rate for item no. 12.0 to 19.0, amc ff engines- composite items, supply & installation of spares for carrying out preventive/breakdown maintenance of diesel engine( make: greaves cotton, model: tbd4 v12) note-spares shall be genuine spares of oem and shall be procurement from m/s greaves cotton or its authorized dealer., cylinder head assly d4i (part no. 123501800036), turbo charger reparing kit (part no. 106907210008), seal dia 25 lngth 16.5, (part no. 104961500008), seal dia 17.5 lng 15.5, (part no. 104961500009), ring set piston d4i 132dia (part no. 123400191357), liner for d4iv12 (p/n: 123501320044), gst rate for item no. 21.0 to 27.0, amc ff engines- composite items, supply & installation of spares for carrying out preventive/breakdown maintenance of diesel engine( make: greaves cotton, model: tbd4 v12) note-spares shall be genuine spares of oem and shall be procurement from m/s greaves cotton or its authorized dealer., turbo charger assly j92 (part no. 1
Tender For supply of transformer oil testing kit (bdv) 1 kva/0-100 kv range motorized cum manual type (digital) for measuring break down voltage /dielectric strength of insulating oil used in transformer/other switchgear s with complete accessories( test equipment, oil test vessel with mushroom electrode assembly, 2.5 mm g o-no-go gauge, main ac cable of suitable length. user manual with test and warranty certificates) .technic al specification as : input power ac 220-250 v/50 hz, output: 0-100 kv ac, trip current: max10-20 ma, op erating temp: 10 to 50 degree centigrade humidity:<75% non considering, o/p voltage resolution: 0.1 kv, accuracy: +2% with digital display. [ warranty period: 30 months after the date of delivery ]
Tender For supply, installation testing and commissioning of hv, lv winding machine and other machine and equipment - h.v. winding machines, l.v. winding machines, spray painting machine, jigsaw with blade, chain pulley block 03 ton motorized, oil pump, power drill machine, hydrolic hand trolley
Tender For corrigendum : construction of 220 160 mva and 132 kv 50 mva gss at hindore rajiasar distt sriganganagar in rajasthan including survey supply of all smaterials erection including civil works testing and commissioning turnkey project - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1250 a, 25 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 50/31.5/25 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specification, lighting panel typ
Tender For corrigendum : construction of 220/132 kv, 1x160 mva and 132/33 kv, 1x40/50 mva gss at 220 kv gss kolayat (distt-bikaner) in rajasthan including survey, supply of all equipments/materials, erection (including civil works), testing and commissioning (turnkey ) - main material/ items, circuit breakers, 220 kv circuit breakers, 220kv circuit breakers (3 ph.) along with support structure, 2500 a, 50 ka, 132 kv circuit breakers, 132 kv circuit breakers (3 ph.) along with support structure, 1250 a, 40 ka, 33 kv circuit breakers, 33 kv circuit breakers (3 ph.) along with support structure, 1600 a, 31.5 ka, instrument transformers, capacitor voltage transformer, single-phase, 220 kv, 4400 pf cvt, single phase 132 kv , 4400 pf cvt, 33 kv potential transformer, 33/ 3 kv /110-110 3, current transformer (1-phase), 220 kv ct, 1000/1 a, 5c, 132 kv ct, 1000/1 a, 3c, 500/1 a, 3c, 33 kv ct, 1000/1 a, 4c, 500/1a, 2c, c&r panels & sas system (complete in all respect, refer section-v a, b, part-iii, volume-ii), new substation, control panel for 220 kv transformer (220 kv side) type: sas-thcb, relay panel for 220 kv transformer (for both hv & mv) type: sas-thrb, control panel for 220 kv feeder type: sas-fcb, relay panel for 220 kv feeder type: sas-frb, control panel for 220 kv bus coupler type: sas-bccb, relay panel for 220 kv bus coupler type: sas-bcrb, 220 kv busbar protection relay panel type: sas-bbrb, control panel for 220 kv transformer (132 kv side) type: sas-tlcb, relay panel for 220 kv transformer (132 kv side) type: sas-tlrb, control and relay panel for 1x 40/50 mva, 132/33 kv power transformer type sas-tcra, control panel for 132 kv feeder type sas-fca, relay panel for 132 kv feeder type sas-fra, control and relay panel for 132 kv bus-coupler type sas-bcra, control and protection panel for 33 kv feeder (i/c, o/g)/bus-coupler/ capacitor bank [for twin feeder/bay] type-fcrd, station hmi [industrial grade computer with 21"tft monitor as per specification requirements], station hmi (hot standby)[industrial grade computer with 21"tft monitor as per specification requirements], hmi view node[industrial grad computer with 21"tft monitor as per specification requirements], a3 size b&w laser printer, substation automation system network panel type sas-nw, modems (both sending and receiving end) for communication to rcc & sub sldc for plcc], data concentrator unit (dcu) at substation for ras mounted in suitable enclosure & fully wired, software: application as well as system software as per specification requirements for various hardware elements for meeting of functional requirement of the specification., substation auxiliary monitoring panel type sas-samp, other items:, fiber optic cables, connectors, ethernet cables, jack panels connectors, patch cords etc. for completing the substation lan as per specification requirements., transducers, sensors etc. (if not considered in the respective equipment/ items) for accumulating monitoring data as per the specification requirements for switchyards., surge arresters, 220 kv la, 132 kv la, 33 kv la, substation lt transformer, 33/ 0.433 kv, 250 kva lt transformer complete with all accessories, fittings, terminal connectors etc as specified filled with transformer oil, batteries & battery charger, batteries (sizing shall be as per requirement of technical specification), 220 v [min. 600 ah], 48 v [min. 600 ah], battery charger system, 220 v float and boost, 50 v float and boost, lighting system, outdoor lighting & other works, lighting fixture type fl-1, lighting fixture type fl-2, outdoor receptacle, type-rp, type-ro, substation premises lighting, lighting poles, type-l1, type-d1, street lighting type-sl-l1 for mounting on poles, street lighting type-sl-d1 for mounting on poles, sub-lighting boxes/panels type -slp at lighting mast and other loaction as designated complete with all controgears and accessories, items etc., lighting panel type acp-2 as per technical specifica