Get complete information related to latest Metering Cubical Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Metering Cubical Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Metering Cubical Tenders.
Tender For supply and installation of commercial ro [supply and installation of commercial ro + uv (1000 lph) water purification plant with one year warranty and two year annual maintenance contract. 1000 lph ro plant consist of the following equipment, * fully ss304 skid heavy structure *ss ro membranes housing 40x80 size - 2 nos. * 13x54 size frp vessel - up to 20 bar operating pressure capacity: 2 nos. * cri make or equivalent raw water pump - 1 hp * cri make or equivalent high pressure booster pump: 2-16 hp * 25nb auto multi port valve 230 volt ac (mpv) - 2 nos. (auto flash system) * proton/infinity / initiative make or equivalent a digital automatic operating panel display 230 volt: 1 no. * ss304 uv chamber with uv tube - 1 no. *1200/2400 rota meter - 2 nos. * glycerin based pressure gauge - 21 kg * sand media (top sand) - 100 kg * 900 iv type carbon media - 50 kg * 40x40 ro membranes working capacity upto 2500 tds and make will be dow/thunder / or equivalent * proton / foxpro make or equivalent a digital dosing pump with 5 liter antiscalent chemical drum - 1 no. each *20
Tender For supply of molded case circuit breakers (mccb) as per is / iec 60947,molded case circuit breakers (mccb) as per is / iec 60947,xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),refrigerant gas r134a,power contactor mcx 255 amp,window ac kit without compressor 2 ton,three pole power contactor type ml2 with aux contact two no two nc,street light fitting 60 watts,100 amp current collector with one meter cable,scale off chemical,split ac indoor kit 2 ton,refrigerant gas r22,split ac outdoor unit without compressor 1 point 5 ton,three pole power contactor mnx32 two no two nc 415 volt,street light fitting 30 watts,split ac indoor unit 1 point 5 ton,window ac kit without compressor 1 point 5 ton,underdeck insulation 25 mm,three pole power contactor mnx25 two no two nc 415 volt,pvc copper cable 4 sqmm three core,duck insulation 25 m
Tender For supply of mm bore , ci foot valve 100 mm dia , water level indicator digital , ci foot valve 200 mm dia , submerssible cable 4 sq mm 3 core copper conductor1100 volts grade , float valve with epoxy coated aluminium rod and high density ball 15 mm , gun metal hydrant valve 63mm , float valve with epoxy coated aluminium rod and high density ball 50mm , gi socket med grade 80mm , brass nozzle 63 mm dia , ci non return vlave 100 mm dia , ms flange 100 mm dia bore , lead pig bar , submerssible cable 2. 5 sq mm 3 core copper conductor1100 volts grade , pvc insulated coper conductor cable of size 16 sqmm single core , self closing taps copper alloy, chromium plated 20 mm , ci foot valve 150 mm dia , float valve with epoxy coated aluminium rod and high density ball 25 mm , ci butterfly valve 80 mm dia , rubber hose real of 20 mm dia , single phase preventor , soda ash , air release vlve 100 mm dia bore , alum crystal , strainer 80 mm bore , spun yarn , relay directly mounted 9 to14 amp type ml 2 by 3 , float valve with epoxy coated aluminium rod and high density ball 40mm , ms pipe meduim grade 200 mm dia bore , power contactor ml 1 point 5 tp 415 volts , change over switch 4 pole in ss enclosure 415 volts 100 amp , nuts ,bolts and washers 25 to 150 mm long of 6 to 20 mm dia , lead wool , ci foot valve 80 mm dia , timer type et 100 240 415 volts , bib taps chromium alloy with crutch handle screwed down for 15 mm dia pipe , gm gate valve 15 mm bore , power contactor ml- 2. 5 tp 415 volts , amp meter off sizes digital type , cable xlpe 4 core 25 sqmm , copper lugs thimble of sizes , brass nozzle 20 mm dia , ci non return valve 80 mm dia , ph meter , pvc insulated coper conductor cable of size 6 sqmm single core , pvc l type holder aluminium rod float ball 50mm , volt meter 0-500 volts , pvc insulated coper conductor cable of size 4 sqmm single core , bearing grease , gland packing 10 mm , ms flange 300 mm dia bore , ms flange 250 mm dia bore , gland packing 6 mm , ms flange 200 mm dia bore , ms flange 150 mm dia bore , air release valve 80 mm dia bore , ms flange 80 mm dia bore , push button switch start stop , battery lead off sizes , pvc insulated coper conductor lcable of size 1. 5 sqmm, single core , submerssible cable 1. 5 sq mm 3 core copper conductor1100 volts grade , mcb spn 32 amps make legrand , pvc insulated coper conductor cable of size 2. 5 sqmm single core , rubber tyton joint 100 mm , rubber tyton joint 150 mm , rubbertyton joint 200 mm , rubber tyton joint 250 mm , gi pipe meduim grade 80 mm dia bore , switch piano flush type 15 amp single pole one way 240 volt , supply only mcb sp 6 to 30 amps make legrand , led lamps 10or 12 watt 240 voltsgi pipe meduim grade 40 mm dia bore, gm gate valve 25 mm bore, ci sluice valve 300 mm dia bore, mccb tp 63 amp 415 volts , float valve with epoxy coated aluminium rod and high density ball 20 mm, change over switch 4 pole in ss enclosure 415 volts 200 amp, gi pipe meduim grade 20 mm dia bore, fasd panel 50 hp , mccb tp 630 amp 415 volts , gm gate valve 50 mm bore, gm gate valve 20 mm bore, power contactor ml- 10 tp 415 volts, air release vlve 150 mm dia bore, ci butterfly valve 150 mm dia, mccb tp 200 amp 415 volts , power contactor ml-6 tp 415 volts, ci butterfly valve 100 mm dia, ci sluice valve 200 mm dia bore, power contactor ml-4 tp 415 volts, battery 12 volts 180 ah, fasd panel 15 hp , power contactor ml-3 tp 415 volts, pvc insulated coper conductor cable of size 25 sqmm single core , submerssible cable 6 sq mm 3 core copper conductor1100 volts grade, on load change over switch 100 amp, ms pipe meduim grade 300 mm dia bore , air //bid details2 / 94
Tender For corrigendum : provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earth fault protection(a
Tender For corrigendum : for the work of fixing of 33 kv meteringcubical and 33 kv ct/pt unit and laying of 33 kv cable for sanction of addition load 2400 and 5930 total 8330 kw of m/s land craft devolopers pvt ltd nh-24 mehrouli gzb under the jurisdection of eudd 9