Get complete information related to latest Microwave Digester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Microwave Digester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Microwave Digester Tenders.
Tender For supply of electro magnetic boom locking system with +(plus) ve vc boom locking ,led indicator panel with buzzer and indication circuit .operating voltage 110v ac or 24 vdc with 110ac/24volt dc adaptor ,electric current 500 ma magnetic locking power 600lbs magnetic convert area for boom locking arrangement size 150mm x 35 mm .fitting plate for boom barrier size 180mm x 35 mm with fitting accessories written in drawing irs condition will be applicable as per specification attached in drawing no-drm/kota/lc/1516.or similiar make. [ warranty period: 30 months after the date of delivery ]
Tender For 1) supply fixing & commissi0ning of wireless three phase pump controller, model- 4g-100u gsm 310, operating voltage (ac); 3 phase- 300 vac to 470 vac, relay over load- 3 phase- 10 amp. make- omron or similar.2) supply fixing & commissi0ning of interface unit operating voltage ac- 200 vac to 240 vac, led indicator, relay model: mk2p, 10 amp with auto manual rotary switch. make- omron or similar. [ warranty period: 30 months after the date of delivery ]
Tender For supply of digital speed indicator (replacement for analog indicator to emd part no.40087769) for single cab hhp passenger diesel locomotives (wdp4) to rdso instruction bulletin no. mp.ib.ec.01.01.20 dt. 04.02.2022 maximum voltage to 9v dc for full scale deflection of 180 kmph. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of heavy duty industrial evaporative air cooler, plastic body, controller type: knob controller, airflow (meter cube/hr)- 16000 or above, motor power- 750 watt or above, fan type- axial fan, speed control- 3 speed, noise -(dba) = 68, cover area - 1500-2500 (sq.ft.), water tank capacity- 180 ltr or above, water consumption- 15-20 l/hour, voltage: 220-240 volt, 50 hz, cooling medium: honey comb pad, auto water inlet, water level indicator, blade- 4, safety steel mesh. [ warranty period: 12 months after the date of delivery ]
Tender For supply of shunt trip coil assy, part no.v0021 , aux. switch assy, part no.v0024 , closing contractor for solenoid, part no.v0027 , flex connector, part no.v0028 , support insulator, part no.v0031 , secondary plug and socket, part no.v0032 , isolator spout for draw out, part no.v0034 , draw out handle, part no.v0038 , support insulator for vcb, part no.v0040 , push to trip assy, part no.v0042 , spring charge indicator, part no.v0043 , gear box assy for drawout vcb, part no.v0047 , vcb assy 800a motorised and drawout, part no.vfs0064 , operating mechanism, part no.om009 , indicating lamp, part no.p0043 , trip neutal close switch, part no.p0045 , ammeter selector switch, part no.p0046a , resin cast core balance transformer, part no.p0051 , under voltage release, part no.p0057 , e l relay test reset switch, part no.p0047 , fall safe relay, part no.p0068 ) /bid number : gem/2026/b/7382672 * /dated: 11-04-2026 & & / bid document 1 / 21
Tender For corrigendum : procurement of spares for mirage aircraft - power supply, mica data link flts, hbj-twt, hbj-cpu interface board, hbj-lv power supply, tua/vem 130 cable a, mdr - pfc power supply, mdr monitoring board, sidl board, iff701ti test set, supervision pc mainframe, air data test set, pressure indicator manometer, oscilloscope, power supply module, high voltage power supply, cw power sensor, low voltage ps, combiner unit, equipped crt, altitude cell, wiring extn rack i, elv dc power supply module, lv dc power supply, base,voltage regulator, electrical safety tester, circuit card assembly, crash recorder (espar ng)
Tender For corrigendum : tender for supply of thermostat for oa 1854 , star delta timer 3 60sec 240v ac 50hz , shaft for fan for ahu , split ac model ftks 71 , liquied line filter drier , core for liquid line filter drier , auxiliary contacts , expansion valve ahu 2 5point6 tr , set of gasket both ends , corrossion protection plug , under voltage relay 415v 50 hz , set of seals for oil cooler , 100a hand change over swithch , 63a hand change over swithch , 160 a mccb , plc electronic module analogue input 6960379 , spares for oil duplex filter , reagent a in plastic bottle 1000 ml , regent b in plastic bottle 50 ml , regent e in plastic bottel 500 ml , regent f in plastic bottle 200 ml , regent g in plastic bottle 500 ml , filter paper 50 nos , fcu 4 fan coil unit , fcu 6 , angle valve 1 4 x 1 4 , gauge pressure compound 0 300 psi 2 dia suction , gauge temp 0point150c dial with 4mtr sensor 6 , main engine f w cooling prpointtransmitter range 0 to 6 bar , gear box s w pressure oulet indicator range 0 to 6 bar , temperature gauges 10 to 50 , temp sensor resistance thermometer pt 100 , starting air pressure transmitter range 0 to 60 bar , starting air pressure indicator range 0 to 60 bar , pcb b1 , electro magnetic valve , drive pin , set of o rings , dry running protection , test cock , level sensing probe , piece distance , gasket , cord type tc air filter insert copper mesh , socket screw , oil separator 7 8 , ring nut , locking washer , thermometer , 5hp 4 pole f 5112m condpointpump motor , gasket , set of spare screws , flow switch , differential pressure relief valve , o ring for filter element , shaft seal , membrance cleaner i , activated carbon , oil seal , oil seal , mechanical seal , kit valve , mechanical seal lp feed pump water , product rotameter , pressure guage 0 140 kg sqpointcm , nc solenoid valve coil 2 way , cd 9 assembly kit , hpointppoint hose 1 bsp , v belt , top cover gasket for cartridge filter , o ring for carbon filter , membrane cleaner ii , membrane cleaner iii , neutralite
Tender For corrigendum : supply of set of voltmeters consist of 02 items (1) voltmeter for battery voltage indication (position no.116) as per clw specification no. clw/es/3/0073 or latest and confirming to clw drg no. clw/es/3/sk1/0073 or latest-01 no. (2) voltmeter for catenary voltage indicator (position no.74.0) as per clw specification no. clw/es/3/0070, alt- nil or latest and confirming to clw drg no. clw/es/3/sk1/0070 or latest - 01 no. [ warranty period: 30 months after the date of delivery ]