Web Analytics Made Easy - StatCounter

Ms Sheet Repair Tenders

Get complete information related to latest Ms Sheet Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Sheet Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Sheet Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39864520 Due date: 07 Apr, 202507 Apr, 2025 NA
Tender For providing and fixing wooden cupboards, aluminum partition and mosquito net for windows and miscellaneous civil work of subdivision offices and circle office under amreli circle.

State Government

CTN :39864521 Due date: 21 Apr, 202521 Apr, 2025 NA
Tender For providing curtain, collapsible gate, aluminum partition and miscellaneous work at anand city division office anand circle office.

CTN :39871372 Due date: 28 Apr, 202528 Apr, 2025 50.00 Lacs
Tender For aluminum section, furniture work and supply of chairs

CTN :39852879 Due date: 16 Apr, 202516 Apr, 2025 NA
Tender For furniture work for computer lab at shri. shivaji agriculture college, amravati. 2. office cabin partition aluminum section with glass and particle board.

CTN :39795347 Due date: 07 Apr, 202507 Apr, 2025 49.40 Lacs
Tender For corrigendum : providing and fixing electrical material including led lights and wiring in nagar parishad anupgarh area. - electrical work, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr .led street light fixture with minimum lumen output 5600 lm, led street light fixture with minimum lumen output 7500 lm, led street light fixture with minimum lumen output 12500 lm, providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un-arrmoured aluminium cable confirming to is:1554 p-i / is :7098 p - i of 1.1 kv with h4- grade electrolytic aluminium conductor confirming to is 8130 of purity >99.6 %, inner / outer sheath confirming to is:5831 in existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench / cable tray (with cable tie) including testing etc. as required of following size. oem must have its own in house nabl accrediated laboratory for testing procedure as per is:10810. for additional technical parameters of product / work refer annexure a attached with this bsr10.0 sq. mm2 core, supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discoms specifications with two coats of red oxide and two coats of aluminium paint etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsrdead end clamp with eye hook & pole clamp, providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p - 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr .40 mm dia., supply and fixing of lt porcelain shackle insulator as per is:1443 1979 and as per discoms standard specifications, suitable for working voltage 1100 volts including all accessories like gi hardware fittings confirming to is:7935/1975 (latest amended) nut, bolt etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr100mm x 110mm, supply & drawing wiring for sub mains isi marked (is:694) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor with 10 swg g.i. support wire duly clipped etc. as required. for additional technical parameters of product / work refer annexure a attached with this

State Government

CTN :36898792 Due date: 08 Apr, 202508 Apr, 2025 37.98 Lacs
Tender For corrigendum : aluminum partition works in control room building for the fote panel installation work at various ehv substation of under eht-construction division satna.

Corporations And Associations And Others

CTN :39827004 Due date: 01 Apr, 202501 Apr, 2025 1.97 Lacs
Tender For providing and erection/laying of pvc/xlpe insulated underground 70 sqmm and 95 sqmm 4 core aluminum conductor cable at water treatment plant in sector-1, u/e, rohtak and all other work contingent thereto

CTN :39815976 Due date: 09 Apr, 202509 Apr, 2025 NA
Tender For repair and overhauling service - 4254 installation of new equipment and degutting of aber equipment onboard ins kora; aber equipment; no; buyer premises-1 degutting of deep fat fryer job 1, (a) marking of cables prior de-connectorisation, (b) de-connectorisation of power supply from the jds/dbs as indicated by ss. precaution, to be exercised while working on jb and work to be carried out in presence of ship staff to, ensure that the said jb is not live., (c j degutting of all associated power and interface cables., (d) loosening/ removal of al foundation bolts for degutting of the equipment. any hot, work/heat assistance required for opening/cutting of foundation bolts is to be catered by, (e) removal of all equipment and subassemblies from foundation and shifting of item to, place as indicated by nsry (svp). assistance in form of crane. fork lift, trailer etc will be, provided by nsry (svp), however, slings, d shackles or any other lifting setup required, is to be catered by vendor., (f) gland packing is to be undertaken post degutting of cables at all effected locations with, compound as indicated, installation of new deep fat fryer, (g) placement of the equipment at the indicated location/foundation by using chain, pulley/trolley etc. due caution is to be exercised so as to not damage the new equipment, while shipping., i(h) tightening of foundation bolts post placement of the equipment, i(j) laying of cables as per bpslwlds from various interfaces/dbs/jbs as indicated, (k) marking of the cables is to be undertaken to identity to and from of the cables, (i) putting of new cable trays for securing of the cables with aluminum clamps and nut, bolts., (m) manufacture and fitment of metallic cable and equipment tallies as per dimension and, test provide by nsry(svp), 2 degutting of cooking range oven with control panel 14.5 kw job 1, (a) marking of cables prior de-connectorisation, (b) de-connectorisation of power supply from the jds/dbs as indicated by ss. precaution, to be exercised while working on jb and work to be carried out in presence of ship staff to, ensure that the said jb is not live., (c) degutting of all associated power and interface cables., (d) loosening/ removal of al foundation bolts for degutting of the equipment. any hot, work/heat assistance required for opening/cutting of foundation bolts is to be catered by, (e) removal of all equipment and subassemblies from foundation and shifting of item to, place as indicated by nsry (svp). assistance in form of crane. fork lift, trailer etc will be, provided by nsry (svp), however, slings, d shackles or any other lifting setup required, is to be catered by vendor., (f) gland packing is to be undertaken post degutting of cables at all effected locations with, compound as indicated, installation of new cooking range oven with control panel 14.5 kw, (g) placement of the equipment at the indicated location/foundation by using chain, pulley/trolley etc. due caution is to be exercised so as to not damage the new equipment, (h) tightening of foundation bolts post placement of the equipment, (j) laying of cables as per bpslwlds from various interfaces/dbs/jbs as indicated, (k) marking of the cables is to be undertaken to identity to and from of the cables, (i) putting of new cable trays for securing of the cables with aluminum clamps and nut, bolts., (m) manufacture and fitment of metallic cable and equipment tallies as per dimension and, test provide by nsry(svp), 3 degutting of cooking range 7 kw job 1, ja) marking of cables prior de-connectorisation, (b) de-connectorisation of power supply from the jds/dbs as indicated by ss. precaution, to be exercised while working on jb and work to be carried out in presence of ship staff to, ensure that the said jb is not live., i(c) degutting of all associated power and interface cables., (d) loosening/ removal of al foundation bolts for degutting of the equipment. any hot, work/heat assistance required for opening/cutting of foundat

Corporations / Associations / Others

CTN :39436669 Due date: 28 Mar, 202528 Mar, 2025 5.89 Lacs
Tender For corrigendum : replacement and repair of old aluminum door/windows in powerhouse and miscellaneous work at switchyard at indira sagar power station, narmada nagar, khandwa (m.p.).

Central Government And Public Sector

CTN :39792206 Due date: 01 Apr, 202501 Apr, 2025 3.21 Lacs
Tender For provision of vitrified tile flooring and dismantling of aluminum partition and wall paneling and other miscellaneous civil work for extension of existing pcm room to accommodate transmission equipments in te compound kaiserbagh lucknow.
 Loading, Please wait...

Connect us via What's Up