Tender For corrigendum : supply of diesel tractor spares - gasket cylinder head , joint cylinder head cover , sump kit , assy connecting tie rod , hub frint wheel regular , seal kit steering cylinder , assembly side shift , assy water pump , metal insert beading , front dial , case
Tender For ttps mech ii tm i unit i ii reconditioning of hp heater 6 7 shell flanges along with renewal of metal gasket and checking of coil puncture during the forthcoming annual overhaul
Tender For corrigendum : rate contract for purchase of various items for repair of failed distribution transformers at nigams workshop - alu lv strip (size as required) dpc(variable with base date 1.6.25), alu hv bare (size as required) semc(variable with base date 1.6.25), cotton tape 1, sleeve 1 mm, 20 mil paper 30, 4 mil paper 24, 4 mil paper 26, 4 mil paper32, 4 mil paper 30, gum, 10 mil paper 20, core clamping insulation 2 mm, yoke various sizes mm, common block various sizes mm, oil duct various sizes mm thickness, stick various sizes mm, wooden spacer 45x45x15 mm, spacer 45x45x3 mm, ring 136x201x2 mm, delta flat 480x30x5 mm, lv chips 380x6x1 mm, foot plate paper 2 mm, p.c phase barrier various size mm, nut g.i.various sizes, washer g.i.various sizes, bolt g.i.various sizes, delta wire various sizes, earthing patti 1 mm thickness tinned copper 20mmx1mm, aluminium flat various sizes mm, delta patti, sleeve 8 mm, sleeve 4 mm, sleeve 6 mm, sleeve 10 mm, sleeve 12 mm, sleeve 1.5 mm, sleeve 2 mm, 1/2 nut g.i., 1/2 lock nut g.i., 1/2 washer g.i., flux, solder wire, copper brazing rod, aluminium brazing rod, brazing powder (l&t), crepe tape 1, 1/2 bakelite, 3/8 bakelite, hv bushing (porcelain,), hv bushing (metal part) complete set, lv bushing (porcelain,), lv bushing (metal part) complete set, ehv grade type-ii transformer oil ( with drum )(variable with base date 1.6.25), prv valve (virat), pvc cap 1/2, ci cap 1.25, paint (green/red/yellow/white/blue), thinner, zinc chromate, cork washer 12x32mm,110x74mmx50x28mm, top cover gasket 50x50x6 mm, oil gauge prismatic glass various size, oil gauge gasket various sizes, oil gauge washervarious sizes, oil gauge nut various sizes, vent pipe gasket 110x110x3 mm, hv clamp, aluminium member, m.s nuts,bolts,washers various sizes, mccb for box 32 amp, mccb for box 40 amp, mccb for box 63 amp, mccb for single phase 25amp, mccb for single phase 40amp, mccb for single phase 63amp, mccb box gasket 500x250x5 mm, silica gel breather, hv bmc, arcing horn with strip & nut bolt, candles mom, backalite sheet 0.50 mm thickness 60x60 mm, u clamp 70 x 50 x 70 mm prv, u clamp ci cap 50x50x50 mm, cloth, lt internal/ oil immerged circuit breaker assorted rating, holdtite, 1/4x2.5 bolt brecker, 1/4 nut brecker, aluminium lugs (various sizes), paint gun, engraving machine, hv farma (size as required), lv farma (size as required), grinder cutter wheel 4, lt bushing box
Tender For corrigendum : replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprenegasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to
Tender For supply of nozzle , coupling bush , piston ring set , inlet valve , cr bearing , metal diode , head gasket , fuel flex pipe big 17 x 17 , liner , fuel flex pipe big 19 x 19
Tender For tender for supply of push button with 1no or 1nc colour red , olr with builtin single phasing protec feature range 23 32a , indicating lamp suitable for 220v ac colour red , hrc fuse fittings 20a with 6a link , pin fulcrum link , key , contactor 40a with 3no 1nc coil voltage 220v ac , contactor 32a with 2no 2nc coil voltage 220v ac , indicating lamp suitable for 220v ac colour green , hrc fuse fittings 20a with 2a link , impeller , bush bearing nde , gasket , pump main bolt , impeller , bearing bush , pump shaft , bellow discharge , impeller , impeller , shaft pump , shaft pump , impeller , de bearing 6208 2z , fuel piping imperial , contactor rated 18a 220v 1no 1nc , contactor rated 12a 220v 1no 1nc , seprator filter water separ , 3 8 od x 5 mtr copper tube , air impeller , impeller , shaft , wearing ring impeller , shaft , impeller , aux contactor , over loard relay , gauge pressure with cock 0 to 6kg gm2 , tie bolts nut , set screw mechanical seal , tie bolts nuts , contactor 70a tp with 2no 2nc aux contact , shaft , shaft sleeve , vacuum breaker , 2 way pn valve 1 1 2 , ball valve 1 1 2 pvc threaded , activator , pump evac se 044a vem motor , seat and cover with hinges , seat and cover toscana , plug , pin suction scanner handle , fuse 20amp , rotor , complete blower with motor , relay control 4pole 14pin 120vac coil lighted , mechanical seal , o ring , coupling pad , seal mechanical , mechanical seal , mechanical seal assly , mechanical seal assly , bi metal thermal 5point5point8a over load relay , i l flexible hose w flange , o l flexible hose w flange
Tender For supply of , gasket allied sheet part no 2363509320 , gasket allied sheet part no 1303509038 , gasket allied sheet part no 2361014272 , gasket allied sheet part no 2361308108 , gasket asbestos part no 2361008050 , gasket copper part no 2011117120 , gasket cork sheet part no 23801009040a , gasket rubber part no 2361104457b , gasket left allied sheet part no 2361002265a , gasket right allied sheet part no 2361002266a , gasket with screen assy part no 2361002283a , gland a c front seal part no 1203509070a2 , governor cover gasket allied sheet part no 236110154a , head gasket allied sheet part no 1303509043a , hood gasket allied sheet part no 2361028162 , inspection hole cover gasket part no 2361110499a3 , intake valve part no 2361007010b , intake valve collar assy part no 2361007262 , lock plate right part no 2361005128a , lock plate left part no 2361005129b , manifold gasket allied sheet part no 2361115026 , o ring rubber part no 2531112221 , oil control ring part no 1303509166 , oil filler neck cover gasket part no 2011114065a2 , plug gasket copper part no 2311009042b , plunger and barrel part no 60111107430 , ring rubber o ring part no 840101208310 , seal assy rubber part no 2361112225b2 , sealing ring rubber o ring part no 236m1111083a , sealing ring rubber part no 2361028246 , sealing ring rubber part no 2361110482 , sealing ring rubber part no 2361110479 , set of crank pin bearing shells part no 2381000104b2p1 , set of main bearing shells part no 2381000102b2p1 , sprayer assy complete with needle part no 26111211001 , thermostate part no tc 107130610006 , washer copper part no 312326n34 , washer copper part no 312471n , washer copper part no 852632n , washer metal plain part no 312672n , washer copper part no 312482n34 , bearing 230a part no 4612121266 , bearing 305 part no 4612133873 , bearing 6205 k part no 4612121626 , cock rc part no 4599300006 , collar part no 2531312603 , fuel feed pump assy part no 2361106210a2 , piston compressor part no 1303509160 , sealing ring copper part no 331112342 , washer copper part no 852212 , washer fiber part no 852204 , water pump assy part no 2361307010
Tender For corrigendum : tender for supply of operation and comprehensive maintenance of ems at kadma te build jsr d d - as per item no-1 of sh-i sor in sec-3 part c of atc , replacement 100amps 4 pole isolator , replacement 63amps 4 pole mcb , replacement 32amps 3 pole mcb , replacement 40-63amps dp mcb , replacement 6-32a spmcb , replacement 100 amps 415v hrc fuse links- din type , replacement 125 amps 415v hrc fuse links- din type , replacement 63 amps 415v porcelain fuse unit , supplying and drawing 3x1.5sqmm wireing , supplying and drawing 2x1.5sqmm , supplying and drawing 3x4.0sqmm , sf pvc junction box along with 150 amp 4 way connectors , suppllying xlpe 1.1 kv al 4x10 sqmm cable , suppllying xlpe 1.1 kv al 2x6 sqmm cable , laying of xlpe cable in ground , laying of xlpe cable on wall surface , laying of cable existing rcc/ hume/ metal pipe , sh 40 mm dia g.i pipe medium class ias per nit. , sm end term with brass gland and alum lugs 4 x 10 sq. mm , sm end term with brass gland and alumi lugs 2 x 6 sq. mm , repl. 63 amps 415 volts tpn sdfu with hrc fuses , repl. 125 amps 415 volts tpn sdfu with din type hrc fuses , repl. 250amps 415 volts tpn sdfu with din type hrc fuses , repl. 400a fp mccb , 36ka overload rel , repl 63 amps 415 volts tpn sdfu in sheet , s/f 36 /40-watt fluorescent tube rods , s/f starter for fl. fittings , s/f 9 /10-watt led lamp (b22) , s/f 12/15-watt led lamp (b22/e27) , s/f 20/22w ultra bright led retrofit tube light , s/f 24w led battype with very high eff 115 lm/w , replacement angle/batten holder , replacement 36/40 w fl tube light holder , replacement 36/40 w fl tube light starter , replacement ceiling rose , replacement 5/6amps 250 volts 3 pin plug top , 15/16amps 250 volts 3 pin plug top , replacement 6 /10 amps 1 way piano type switch , replacement 16 amps 1 way piano type switch , replacement 6 amps 3 pin type socket , replacement 16 amps 3 pin type socket , rewinding of 1200mm/1400mm ceiling fan etc. as required. , repl stepped type electronic fan regulator (switch type) , rep 2.25 mfd 440 volts capacitor for ceiling fan , bearings for ceiling fans etc. as required (make skf/ss) , rewinding 380mm 1500 rpm 230 v heavy duty exhaust fans , supply and replacement of 45 watt street light , supply and replacement of 27 watt street light , dehyd filt & testing of existing trasformer , supplying of new transformer oil , replacement gasket of transformer , replacement lt side stud bush , painting of transformer with good quality synthetic paint , s/f diesel filter with o ring (primary) 160kva d e/a set , s/f lub oil filter with o ring 160kva d e/a set , s/f diesel filter with o ring (secondary) 160kva d e/a set , s/f engine oil(mobil) 160kva d e/a set , sevicing by authorised dealer /oem for160kva dg set