Web Analytics Made Easy - StatCounter

Network Communications Device Tenders

Get complete information related to latest Network Communications Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Network Communications Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Network Communications Device Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39440111 Due date: 24 Mar, 202524 Mar, 2025 NA
Tender For "supply, installation, testing and commissioning of various passenger amenity items including bogie/ coach position indicator boards and main line indicator boards, coach guidance system ,train information display, data network equipments and other telecom assets at csmt station in mumbai division of central railway".

Central Government/Public Sector

CTN :39171113 Due date: 03 Mar, 202503 Mar, 2025 1.80 Crore
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene

CTN :39277945 Due date: 03 Mar, 202503 Mar, 2025 99.86 Lacs
Tender For supply installation testing and commissioning of cctv camera system - supply of 80ch embedded network video recorder , supply of 5mp dome camera , supply of 5mp bullet camera , supply of 2mp dome camera , supply of 2mp ptz dome camera , supply of hdd 6 tb sata interfaces , supply of category 6 unshielded 4 pair cable , supply of category 6 utp patch cord , supply of category 6 utp patch cord , supply of 12 core ofc singlemode armored outdoor cable , supply of 24 port liu rack mount with fully loaded , supply of lc lc singlemode duplex patch cord , supply of core switch 24 port , supply of access switch 24 port , supply of 10g uplink sfp module , supply of video encoder , supply of media converter , supply of bnc patch cord , supply of 55 inch display , supply of 43 inch display , supply of client workstation , supply of 12u rack wall mount with power manager and fan , supply of 42u rack 19 inch network rack with accessories , supply of pvc capping casing 2 inch cross 2 inch , supply of pvc capping casing 1 inch cross 1.25 inch , supply of 1 inch pvc pipe , supply of 1 inch pvc bend , supply of 3 by 4 inch pvc bend , supply of clamp for pvc fixing , supply of flexible hose stainless steel , supply of outdoor junction box for fixing cameras , supply of rj45 connectors , supply of 6kva ups - 120 minutes backup with accessories and suitable battery bank. , supply of 3 core 2.5 sq mm power cable , supply of 3 core 4 sq mm power cable , supply of electrical junction box with 2 switches and 2 power sockets of rating 240v , supply of 12 way db one with 2 pole 2 nos mcb 2 nos and single pole 5 nos. , supply of 6mm screw , 6mm fisher , insulation tape , cable tie , installation and configuration 80 ch embedded network video recorder , configuration and fixing of 5mp dome camera with accessories , configuration and fixing of 5mp bullet camera with accessories , configuration and fixing of 2mp dome camera with accessories , configuration and fixing of 2mp ptz camera with accessories , installation and raid configuration surveillance hdd 6 tb sata interfaces , laying of utp cat 6 cable , termination and fixing cat6 24 port patch panel , termination and fixing cat6 information outlet patch panel side , laying of 12 core ofc single mode central loose tube armoured , fixing and splicing 24 port lc type liu single mode , configuration of core switch 24 port , configuration of access switch 24 port , fixing of 55 inch display uhd , fixing of 43 inch display uhd , itc for client workstation , fixing of 12u rack wall mount with power manager and fan , fixing of 42u rack 19 inch network rack with accessories , laying of pvc capping casing 2 inch , laying of pvc capping casing 1 inch , fixing of pvc outdoor junction box for fixing cameras , termination of rj45 connector , installation of 6 kva ups with suitable battery bank. , laying of 3 core 2.5 sq mm power cable fr , laying of 3 core 4 sq mm power cable fr , fixing of electrical junction box with 2 switches and 2 power sockets , itc of 12 way db one with 2 pole 2 nos mcb 2 nos and single pole 5 nos. , installation testing commissioning with documentation and drawing

CTN :39197645 Due date: 24 Feb, 202524 Feb, 2025 NA
Tender For supply of pacs archive software license , radiology information system softwar license , vendor neutral archive license , zero footprint dicom viewer server license , concurrent user license , dicom radiology workstation software license , clinical dicom viewing software license , speech recognition software license from augnito , cd or dvd burning or pendrive software license , tele radiology software , server hardware , storage hardware , network switch hardware , workstation hardware , 8mp medical grade monitor hardware , ups for workstation , ups for server and storage , 1gbps edge switch hardware , networking for servers, storage, modalities and workstations, and to connect to the hospital it network. 30 network points to connect modality and workstations.
 Loading, Please wait...

Connect us via What's Up