Tender For ece lab items dept use - eliminator transformer (step-down) kitinput - 220v - 240v ac, 50 hz, output-2v to 12v dc, 0-2 a ripple: 5mv, strain gauge trainer kitmetal foil strain gauge mounted on beam/cantilever strain measurement under applied load wheatstone bridge arrangementsignal conditioning and amplification circuitinstrumentation amplifiers, 3 digit display of strain / output voltage zero and gain adjustment controlsprovision for applying calibrated loads regulated power supply, 230 v ac, 50 hz table-top trainer with labeled paneltest points to measure the signalsbuilt in power supplies and wooden closed cabinet supplied with patch cords and experiment manual, temperature measurement kitsensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc).display: 3 digit led/lcd digital display (typically 200mv fsd). temperature source: portable water kettle or heater block.signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation.test points: multiple 2mm/4mm banana sockets for monitoring input/output signals.power supply: 230v ac, 50hz, single-phase.accessories: includes a glass thermometer, ntc thermistor probe 10k, k-type thermocouple probe, patch cords, and instruction manual., sim reader trainer kitsim compatibility supports 2g 3g 4g lte sim cards,sim reader mode: reading writing gsm sim card data, imsi, ki codes, phonebook interface usb 2.0 or rs 232 serial port for pc communication.clock frequencies: selectable frequencies 3.579 mhz, 7.159 mhz, 14.318 mhz for sim card operation.power supply: onboard smps 12v 2a or 5v dc with overload protection. hardware components:6-pin or 8 pin sim card socket.led indicators for power, sim reset, and data activity.optional lcd 128x64 and keypad 20 keys for standalone operation. software tools support for at commands gsm etsi 07.0707.05, sim manager utilities, and data logger functionality. common trainer kit featuresfault simulation ability to create faults e.g., sim not detected, vcc failure for troubleshooting.test points: multiple test points e.g., 55 nos for observing signals sim rst, clk, i o via oscilloscope.construction tested glass epoxy pcb, often housed in a study educational case., dual output regulated dc variable power supplydual output regulated power supply- input voltage: 230v/50hzac- output voltage: (0 30v)dc- output current: (0 2a)dc- protection circuit: over voltage and over current protection, short-circuit protection- high efficiency: greater than 85%- low ripple and noise: less than 50 mv, lvdt sensor trainer kitac mains power supply : 230v 10%, 50hzfixed regulated dc power supply : +5v, 12v 500matransducer : lvdtlvdt displacement : 20mm (40mm total)displacement scale : linear 20mmdisplacement display (mm) : red color 3 digit led displayexcitation frequency : 4khzexcitation voltage : ac variable 5v, dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc, accuracy: class 0.5( 0.5 % full-scale), dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc, accuracy: class 0.5 ( 0.5 % full-scale)
Tender For purchase of lab equipments for ice dept - purchase of lab equipments for ice dept, i/p and p/i converter (iemcode:g002) i/p converter:(4 20) ma to (3 15) psi conversion. p/i converter:(3 15) psi to (4 20) ma conversion. air filter regulator (afr):20 psi regulated air supply. built-in current source. 3 digit led display for process indication. power supply: 230 v ac, 50 hz. mounting:bench-top / panel-mounted trainer configuration., levelmeasurement using float and sight glass indicator- itemcode: g005specifications: sight glass level indicator. float type level indicator. power supply:230 v ac, 50 hz. monoblock pump:0.5 hp / 1 hp. sump tank., 8051develop ment board with usb/rs 232 cable to connect with computer (item code: g008)specifications: communication interface:usb / rs-232. on-board facilities:8 output leds,8 input switches,ldr,reed switch,8-bit adc,8-bit dac. display interfaces:seven-segment display,16 2 lcd interface. motor interfacing:stepper motor with driver,dc motor with h-bridge driver, 8 bit adc/dac interface board (item code: g009)specifications: thermistor / lm35 input in one channel. variable input (0 5) v in another channel. 8 leds for digital output indication.. necessary control signals provided for adc0809. 8-bit dac using dac0808. 8-bit digital input from controller. single-channel dac output:(0 10) v. power supply: 12 v or 15 v for analog circuitry, water levelmeasurement trainer kit using capacitive type transducer (item code: g020) tabletop model with transparent acrylic tank of approximately 50 cm height. capacitive type level sensor for continuous levelmeasurement. sensor output: (4 20) ma and/or (0 5) v with built-in signal conditioning. vertical pump for water circulation from sump to tank. flow control valve, overflow, and drainage arrangement. digital display for water level indication in cm. power supply: 230 v ac, 50 hz, single phase. in-built regulated dc power supply for sensor and control circuit. mounted on powder-coated ms frame for laboratory use. suitable for calibration and study of capacitive levelmeasurement., flow measurement using electromagn etic flow meter(item code: g021)specifications: medium: water (salt water / bore well water). electromagnetic flow measurement: instantaneous flow rate and totalized flow indication. electromagnetic flow meter: integral mounted type. power supply: 90 260 v ac, 50 hz. minimum media conductivity: 15 s/cm. flow rate unit: m /hr. operating pressure: up to 10 kg/cm . electrode material: ss-304 / ss-316 / ss 316l. lining material: ptfe / neoprene / hard rubber / pfa. line size: 15 nb 25 nb. flow range: 0.1 10 m /hr. connection type: flanged. display: digital indication for flow rate and totalized flow. water pump: submersible type, 230 v ac, 50 hz. water tank: approximately 20 25 liters capacity. flow control valve provided. drain valve and overflow arrangement provided. mounted on powder-coated ms frame suitable for laboratory use.
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
Tender For purchase of equipments for eee department - 3 phase capacitor bank :* 3-phase capacitor bank * rating: 2 kvar * voltage: 440 v ac * frequency: 50 hz * heavy duty self-healing capacitor units * powder coated ms enclosure * compact panel mounted/floor mounted construction * proper ventilation arrangement to be provided * capacitor duty contactor/switch to be provided * fuse/mcb protection to be provided * discharge resistors to be provided for safety * proper earthing arrangement provided, 3 phase auto transformer starter :* 3-phase variable autotransformer * input: 415 v * output: 0 470 v ac (continuous) * current: 15 a * copper wound, carbon brush type * heavy duty toroidal/core construction * mounted in powder coated ms/crca enclosure * front panel mounted voltage control knob with scale indication * proper insulated terminals provided * floor/bench mounted type suitable for laboratory use * input/output terminal arrangement provided * mcb/fuse protection provided * proper earthing terminal provided * ventilation arrangement for heat dissipation, linear variable differential transformer measurement trainer :* input supply : 230 v ac, 50 hz * type : linear variable differential transformer (lvdt) trainer kit * lvdt stroke length : 25 mm * lcd display provided * digital voltmeter provided for output measurement * potentiometer provided for calibration and adjustment * signal conditioning circuit inbuilt * zero adjustment and calibration facility provided * test points provided for waveform/signal observation * clearly labeled circuit diagram on front panel * proper insulated terminals and safety sockets provided, plc trainer kit :* plc make :allen-bradley / delta electronics / siemens or equivalent* digital inputs : 8 20 nos.* digital outputs : 6 12 nos. (led / relay type indication)* communication port : rs232 / usb / ethernet (if available)* programming method : ladder logic programming* toggle switches for digital input simulation* led indicators for output status indication* analog potentiometers for analog input experiments* proximity sensor interface provided* relay output interface provided* input supply : 230 v ac, 50 hz* built-in regulated 24 v dc power supply* ladder diagram programming software to be provided* compatible programming software license to be provided* suitable for basic plc programming and automation experiments, conveyor arrangement with siren :* input supply : 12 v dc / 24 v dc / 230 v ac, 50 hz* control mode : manual / automatic operation using plc* conveyor arrangement with geared dc motor provided* proximity sensor provided for object detection* start and stop push buttons provided* audio siren indication provided* plc based control and sequencing operation provided* mini conveyor setup suitable for laboratory demonstration* geared dc motor driven conveyor mechanism* smooth belt movement with roller arrangement, digital storage oscilloscope (dso) :* bandwidth: 50 - 100 mhz. * sampling rate: 1gs/s. * channels: 2 (minimum) * power supply: 100v 240v ac, 50-60 hz * automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., * horizontal scale: 5 ns/div 50 s/div or equivalent * vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) * waveform math: +, -, x , , invert, fft etc., * waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. * 7-inch color display or equivalent * input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), on/off control of lamp using solid state relay kit:* type : solid state relay (ssr) trainer kit* control/input voltage : 12 v / 24 v dc or up to 30 v dc* output load voltage : 230 v ac, single phase* load control : on/off control of ac lamp load* solid state relay based switching circuit* opto-isolated input control* built-in ac lamp load* manual on/off switching arrangement* led indication for input and output statu
Tender For procurement of various testing equipments used for transformers, protection relays, and circuit breakers of unit 1 and 2 katpp, jhalawar - various testing equipments for transformers, protection relays, and circuit breakers, transformer winding resistance meter(25a dc max. current injection, multiple autoand manually selectable measurement ranges: 200 to 2k ), earth ground resistance testing kit(measuring range 2 m to 10 k ), contact resistance measurement kit(test injection current max. 200a dc, resistance range 200 to 20 m ), relay testing kit (single phase)(output current range :- 0 to 30 a at 200 va continuously up to 60 a at 300 va for short duration, output voltage range :- 0 to 300 v at 150 va)
Tender For procurement of various testing equipments used for transformers, protection relays, and circuit breakers of unit1 & 2 katpp, jhalawar - transformer winding resistance meter , (25a dc max. current injection, multiple auto and manually selectable measurement ranges: 200μω to 2κω. detailed specifications at annexure-1) , earth ground resistance testing kit , (measuring range 2 mω to 10 κω. detailed , specifications at annexure-l) , contact resistance measurement kit , (test injection current max. 200a dc, resistance range 200 μω to 20 m2. detailed specifications at annexure-i) , relay testing kit (single phase) , (output current range :- 0 to 30 a at 200 va continuously up to 60 a at 300 va for short duration, output voltage range : 0 to 300 v at 150 va. detailed specifications at annexure-i)
Tender For tggenco-supply of tan delta and capacitance test kit equivalent of cpc 80pf/df test system incl. cp td12 along with laptop for capacitance and power /dissipation factor measurement of transformers, bushings, current transformers and voltage transformers of 400kv switchyard and transformer yard equipment of ytps.
Tender For corrigendum : supply of analog electrician tool kit, availability of multimate of standard make with tool kit : yes, typeof multimeter provided with kit : analog, make of multimate : others, if multimate is of others make , specifythe make : others, dc voltage range for multimate in volts upto 200v, dc current range for multimate in amp : upto 2 ma, ac voltage range for multimate in volts : upto 200 mv, ac current range for multimate in amp : upto 2 ma, resistance measurement range in ohms : upto 20 ohms, screw driver with individual handle and arm provided in kit : 5, arm diameter of screw driver in mm : 3 mm,3.5 mm,4 mm,5 mm,6 mm,8 mm,10 mm, arm length of screw driver in mm : 50,75,100,125,150,175,200,250,300, hexagonal socket wrench with bits : yes, precision bit sets : yes, ratchet hand screwdrivers(reversible high torque type ) : yes, " allen key set of 12 pieces (2mm to 14mm), provided in tool kit " : yes, combination plier in kit confirming to latest is : yes, number of combination plier provided with tool kit : 1,2,3, size of combination plier ( highgrade forged steel with insulated handle ) confirming latest is : 6 inch, make of combination plier : taparia, number of flat nose plier : 1,2,3, size of flat nose plier in inch : 6, no of steel rule 30 cm inch and metricprovided in the kit : 1,2,3, wire stripper or wire cutter : yes, size of wire stripper or wire cutter in inch ( high grade forged steel )confirming to is 5087-1969with latest amndmnt : 6 inch,8 inch, ball pin hammer with rubber handle : yes, ball pin hammer with rubber handle in kgs : 0.5, torch ( single set) 9 pearl led flashlight : yes, masonary drill bit : yes, file provided in tool kit : yes, branded s-plugs ( set of 30 pieces ) : yes, knife blade of high quality material : yes, availability of hand drilling machine : yes, warranty : 1, make :tap aria, bosch, ibell [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of calibration and installation of maintenance testing kits include the following equipment: dcrm (dynamic contact resistance measurement) ultima (3ch), (make: scope, model no. dcrm ultima 3ch; hisac ultima, make: scope, model no. hisac ultima; crm contact resistance meter, make: scope, model no. 200 b+; wrm contact resistance meter, make: scope, model no. trm 104; and the primary current injection testing kit prima 02, make: scope, model no. prima 02 or nabl-accredited test laboratory or similar) . the detailed quantity of all calibration kits shall be as per annexure a. calibration for all equipment shall be carried out by the oem or a nabl-accredited test laboratory, and the calibration shall be performed at the sse/ trd/kmz office in the jabalpur division. all items shall carry a warranty of 12 months from thedate of delivery. [ warranty period: 12 months after the date of delivery ]