Tender For supply of silicon valve and packing grease oks 1110/6 or its equivalent in stan-vac as per parameters given. 1.parameter: appearance requirement:water white. 2.parameter:temperature range requirement: +40 deg. c to + 260 deg. c. 3.parameter:worked penetration requirement: 300 to 320 0.1mm at 25deg.c 4.parameter:density at +27deg. c requirement:0.90-0.98 g/cc. 5.parameter:water resistance test requirement:0-90 din 51807. 6.parameter:drop point requirement:> +250 deg c.7.parameter: base requirement:silicon oil,inorganic thickener. 8.parameter:base oil viscosity at+25deg c requirement:12500 cst.3. p as per drg.no. 9. parameter:packing requirement: sealed container [ warranty period: 30 months after the date of delivery ]
Tender For supply of consumables of cardiac catheterization lab for gbph, sri vijaya puram - puncture needles (adults), puncture needle for vascular access in adults 18 g 6- 7.5 cm long should be compatible with 0.038 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, puncture needle dedicated for radial artery access in adults 20- 22 g 3- 5 cm long should be compatible with 0.021 - 0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for vascular access in adults 20- 22 g 6- 7.5 cm long should be compatible with 0.018 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for radial artery access in adults 20-22 g 3-5 cm long should be compatible with 0.021-0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, introducer sheaths (adults), introducer sheath for adults and pediatrics (sizes 4 -9fr.) - standard length sizes 4- 9 fr 10- 11 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath with puncture needle for adults (size 5- 9 fr) - standard length sizes 5- 9 fr 10-11 cm long pack must include 18 g, 6- 7.5 cm long puncture needle 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, long introducer sheath (size 6- 7fr) 20-50 cm long sizes 6- 8fr sheath should be between 20-50 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath for radial access introducer sheath dedicated for transradial access sizes 4- 7 fr between 7- 16 cm long 0.021 - 0.025 inch guide wire compatible pack must include 20-22 g, 3.5 cm long puncture needle with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath m coat hydrophilic coating kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer slender sheath for radial access transradial slender sheath systems 5f 10 cm capable of introducing 6f catheter with hydrophilic coating on sheath ,tapering dilator hydrophilic straight polymer 0.025 wires and 20g plastic cannula for puncture . should be fda/ce/dcgi approved, introducer slender sheath for radial access transradial slender sheath systems 6f 10 cm capable of introducing 7f catheter with hydrophilic coating on sheath, tapering dilator hydrophilic straight polymer or stainless steel 0.021 or 0.025 wires and 22 g / 20g plastic cannula for puncture should be fda/ce/dcgi approved, guidewires (adults), ptfe coated diagnostic guide wire - regular length, regular stiffness should be available in 0.025, 0.032, 0.035 and 0.038 inches size should be between 145- 180 cm long should be available as straight & j shape tip should be available in variable lengths of flexible/floppy end should be available in variable j tip sizes should be available in fixed as well as movable core, ptfe coated diagnostic guide wire - exchange length, regular stif
Tender For supply of procurement of 2000 and 5000 hourly gear box routine kit c c -spare set for oil cooler , anode , grooved ball bearing 6209zj , grooved ball bearing 6209 j c3 , spare set for built on sea water pump , valve insert , casing seal 73 x 5 mm , o ring , filter element , pressure limiting valve , pressure gauge 0 5 bar , pressure gauge 0 10 bar , pressure gauge 0 40 bar , pressure switch 0 02 2 bar , pressure switch 0 5 30 bar , pressure switch 0 2 12 bar , resistance thermometer 0 1200 c l 110 , resistance thermometer 0 1200 c l 140 , resistance thermometer 0 1200 c l 130 , resistance thermometer 0 1200 c l 120 , resistance thermometer , proximity switch ) /bid number: gem/2025/b/7058475 * /dated: 16-01-2026 & & / bid document1 / 24