Web Analytics Made Easy - StatCounter

Office Cabin Tenders

Get complete information related to latest Office Cabin Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Office Cabin Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Office Cabin Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :45415605 Due date: 17 Jun, 202617 Jun, 2026 3.22 Crore
Tender For corrigendum : reconstruction/repair of civil structures and laying of damaged rising main and distribution at various locations under sassci work wise details given annexure i - restoration works of jal shakti (phe) city division no.i including reconstruction / repair of civil structure and laying of damaged rising main and distribution at various locations uinder sasci (phe sector). name of works:a.restoration of rising main and washed away supports of 8" rising main in lower roop nagar. b.damage of compound wall at tibba section of sub- division dhounthly. c.constuction of main gate / barbed wire fencing / road/ wall damaged near gsr 22.50 lacs glns at lohar station. d. restoration of boundary wall, roof and floor of the pump room building at phase iind muthi pumping station. e. improvement / restoration of damage chain link fencing around intake structure at cps nai muthi. f. construction of protection work to protect tube well and pump room at muthi left and muthi 6 and muthi 7 tube well at cps nai basti. g. providing and laying damage rising main at tube well muthi left, tube well no.6 and tube well no.7 nai basti at cps nai basti. h. repairement of the tube well buildings at muthi left, muthi 6, muthi 7 and cps naibasti. i. raising of udheywala station and construction of manifold and allied works of welding at tube well no.5 udheywala and suryavanshi nagar station of sub-division muthi. j. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 1st. k. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 2nd. l. uplifting the central pumping station samadhian by way of shifting civil, electromechanical infrastructure of sub-division dhounthly under phase 3rd. m. construction of 200000 glns sump tank at cps samadian. n. shifting of pipe utiliies at brick klin tube well and its allied works. o. reconstruction / repairment of bath room at sub-division dhounthly and muthi. p. restore the front area by way of laying paver blocks at cps gujjar nagar. q. erection of truss over the damage roof top central pumping station cps muthi goan. r. erection of truss over the damage roof top central pumping station and dismentaling of staff qtr at station cps gujjar nagar. s. reconstruction of damage operator qtr at cps gujjar nagar under dhounthly sub-division.

State Government

CTN :45516376 Due date: 18 Jun, 202618 Jun, 2026 4.23 Lacs
Tender For general-non plan 2026-27 premonsoon work for the year 2026 -27 clearing the premises, cleaning roof top, sunshade, cutting of branches of trees, clearing drain, septic tank waste pit etc in civil station compound, ngo qtrs, and other govt buildings under building section edappally.-estimate-general civil work-1

corporations/Associations/Others

CTN :45541386 Due date: 06 Jul, 202606 Jul, 2026 14.00 Lacs
Tender For supply and commissioning of 01 (one) unit of anaesthesia work station for a new ot of dr. r. ahmed dental college and hospital

Central Government/Public Sector

CTN :45301461 Due date: 20 Jun, 202620 Jun, 2026 45.00 Lacs
Tender For corrigendum : repairs to floor plastering work sanitary and plumbing cupboard work at stn gym noi swimming pool religious institue shivaji auditorium nofra area under age b/r-i at naval station karanja

Central Government And Public Sector

CTN :45540228 Due date: 04 Jul, 202604 Jul, 2026 51.80 Lacs
Tender For performing the work of removal of floating waste and solid waste materials with floating trash skimmer machine and shore conveyor at dam nimoo bazgo power station alchi, distt. sham

CTN :45540533 Due date: 23 Jun, 202623 Jun, 2026 52.41 Lacs
Tender For annual contract for operation and dewatering work at various power stations of mahi hydel power station, rvunl, banswara

CTN :45446505 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digital ultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont

CTN :45540835 Due date: 28 Jun, 202628 Jun, 2026 NA
Tender For annual civil maintenance work of colony and office premises at 110/33 kv sub station bapat camp, dist-kolhapur.(rfx no. 7000040305)

CTN :45528791 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For srm e-tender for bmc for overhauling work of 33kv dc mocm (type hlr 100/2932 es & 2931 es mocb) at hvdc terminal station, chandrapur.

CTN :45515274 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For srm e-tender: annual maintenance contract for work of uprooting of grass, plants, weeds, small trees, etc., along with weed control (chemical treatment) and disposing the removed weeds/ grass from inside yard and at outside live switchyard area where metal is not laid, overall approach road and garden area, diesel generator set area, station transformer area and backside of control room and work of providing pest control i.e anti-termite, anti-reptile & rodent control treatment, and anti-malaria & dengue spraying treatment at 400kv rs thaptitanda.
 Loading, Please wait...

Connect us via What's Up