Tender For supply of set of lube oiltemperaturegauge and sensor consisting of 2 items. 1. lube oiltemperaturegauge to cummins part no. 4071831 - 01 nos. 2. sensor to cummins part no. 4071834 - 01 no. suitable for cummins nta- 855r engine. [ warranty period: 30 months after the date of delivery ]
Tender For supply of emerson make butterfly valve spares - valve positioner 3610j f cntrl vlv , positioner pneu f fisher c v , vollume booster 2625 fisher , regulator ss with gauge fs67dfsr 25 c7 , disk p n ge23790x012 , valve gasket blind flange ge21172x012 , v r packng ptfe 0.75 in epm 12a8995x022 , seal ring outer ptfe and bronze fcon cv , shaft pn ge29227x022 , spare actuator diaphragm for 2in valve
Tender For bid to ras bid to ras corrigendum : supply of gland steam inlet control valve, gland steam dump control valve, lube oiltemperature control valve, spare for smart e/p positioner of cv, actuator for gs inlet control valve, actuator for lo temp control valve, diapgragms for gs inlet control valve, diapgragms for lube oil temp ctrl vlv, o-rings and seal for gs inlet ctrl vlv, o-rings and seal for lo temp ctrl vlv, pressure gauge for ctrl vlv positioner, pressure gauge for ctrl vlv air set, set of stem packaging for gs i/l cv, set of stem packaging for lube oil tcv, set of valve trims for gs i/l cv, set of valve trims for lube oil tcv, air lock relays, air filter regulator, turbine exhaust hood spray cv, actuator for exhst hood spray on-off cv, diapgragms for eht hood spray on-off cv, o-rings and seal for eht hood spray cv, sol vlv for exhst hood spray on-off cv, set of vlv trims for exht hood spray cv, set of stem packaging for exh hood cv, actuator for gs dump control valve, diaphragms for gs dump control valve, o-rings and seal for gs dump ctrl vlv, set of stem packaging for gs dump cv, set of valve trims for gs dump cv, coil for sov of exthood spray on-of vlv, set of retainer and seal ring gs i/l cv, set of retainer and seal ring gs dumpcv, set of retainer and seal ring lo tcv, set of retainer and seal ring ex hoodcv
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperaturegauge, oiltemperaturegauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge