Tender For supply of oiltemperatureindicator 0-150 degree c, union type 3/4 inches bsp male as per annexure a , winding temperatureindicator 0-150 degree c, union type 3/4 inches bsp male as per annexure b , oiltemperatureindicator 0-150 degree c, union type 1 inches bsp male as per annexure c , winding temperatureindicator 0-150 degree c, union type 1 inches bsp male as per annexure d
Tender For supply of testing of earth pit , testing of relay , thermography of equipment , preparation of earth pit layout , testing of insulation mat , load testing of battery bank , transformer oil testing , testing of transformer tan delta , testing of transformer partial discharge , routine testing of transformer , servicing and testing of vcb , wti winding temperatureindicator calibration , oti oiltemperatureindicator calibration , buchholz relay testing , testing of third harmonic la , testing of vcb bottle , vlf testing of cable 100 percent , polarization index testing motor , insulation resistance testing , electrical safety audit , calibration of voltmeter , calibration of ammeter , cablibration of energy meter , cablibration of power factor meter , acb servicing and testing , pair of ht electrical gloves, 25 kv, is 13774 2021 , pair of lt electrical gloves, 1.1 kv, is 4770 1991 , insulation mat 2.5 mm, lt, is 15652 , insulation mat 3 mm, ht, is 15652 , oltc oil testing as per is 1866 , dga of transformer oil , transformer oil filtration , thermal omicron b2hv relay test , testing of mccb , testing of rccb , pi of power cables , current transformer testing , digital megger meter , led 300 watts for high mast tower , digital ampere meter , communication cable tester , digital clamp meter * /bid number : gem/2026/b/7664367 + /dated: 17-06-2026 ' ' / bid document 1 / 51
Tender For corrigendum : supply of digital type transformer winding temperatureindicator (wti) and oiltemperatureindicator (oti) as per enclosed detailed specifications. valid test reports, product catalog and productdatasheet shall be supplied along with supply of the material. [ warranty period: 12 months after the date of delivery ] ]
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oiltemperatureindicator & winding temperatureindicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oiltemperatureindicator & winding temperatureindicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]
Tender For corrigendum : supply of winding temperatureindicator with 4 switches 12 meters capillary length with potentiometer , oiltemperatureindicator with switches 12 meters capillary length with potentiometer , remote winding temperatureindicator with 4 sets of contacts , perpex container for breather , propex container for breather 15 mva , bucholze relay , buchholz relay for main conservator for , buchholz relay for service transformer , pressure relief valve , pressure relief device with 2 no contact , magnetic oil gauge , 50 nb manual butterfly valve
Tender For supply of thermometer sensor (oiltemperatureindicator) ,make bhel or jumo make ( part no 608520/2380) suitable for 1578 kva transformer fitted in 3 phase bhel ac emu rake. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of digital type transformer winding temperatureindicator (wti) and oiltemperatureindicator (oti) as per enclosed detailed specifications. valid test reports, product catalog and productdatasheet shall be supplied along with supply of the material. [ warranty period: 12 months after the date of delivery ] ]