Tender For lis to bami nallah in gp hurla, naresh and diyar tehsil bhunter.h.p( sh- civil work, wood work , foundation bed for installation of pumps and motor ,electrical fitting for pump house and erection commissioning and testing of pumping machinery at stage-1,2and 3) (balance work )
Tender For supply of air terminal single pointed aluminium of 12mm dia 300mm long with 50mm treading at the bottom with gi bolt , gi earthing plate 600mm x 6mm suitable for fitting earthing strips , nut and bolts gi washer size 15mm x 4 inch , common salt , wood charcoal , nut and bolts brass 6mm x 1 inch , aluminium conductor 25mm x 3.15mm complete with saddle fixing screws , aluminium strips 32mm by 6mm , gi pipe 20mm bore medium grade with sockets , gi pipe 40mm bore medium grade with sockets , funnel of pgi sheet with 4 inch dia , ci earth pit cover medium 300x300x6mm with frame , gi elbow of 40mm dia isi marks , testing point terminal block made of gun medal , 2nd class hw timber scanttling , ms clamp of size 25x3mm , pvc insulator for fixing aluminium strip , wooden block as per sample for fixing of aluminium strip , cement ppc in 50 kg , sand for best quality , stone aggregate 10 to 20mm
Tender For supply, installation, testing and commissioning of internal wiring of pump house in pvc casing capping on surface of wall and supply of 50w to 100w led flood light at required place. all wiring work as per is 732. making wiring point for exhaust fan, light, plug, led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated of multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for light and 15a/16a for exhaust fan, power plug) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (0.5a to 5a and 6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). power wiring should be done by 2.5 sqmm multi strand copper wire. dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractor at saryu pump canal, stage-ii nanpara, bahraich under modernization project of electriacal & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich
Tender For supply, installation, testing and commissioning of internal wiring of pump house in pvc casing capping on surface of wall and supply of 50w to 100w led flood light at required place. all wiring work as per is 732. making wiring point for exhaust fan, light, plug, led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated of multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for light and 15a/16a for exhaust fan, power plug) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (0.5a to 5a and 6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). power wiring should be done by 2.5 sqmm multi strand copper wire. dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractor at saryu pump canal, stage-iii nanpara, bahraich under modernization project of electriacal & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich.
Tender For supply, installation, testing and commissioning of external wiring around outer wall of pump house in pvc casing capping and wiring of long steel tubular pole with aluminum conductor pvc insulated armoured sheathed cable 1100v for 50w to 100w led flood light at required place. all wiring work should be as per is 732 and is 1944. making wiring point for led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for led flood light) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractoratat saryu pump canal, stage-ii nanpara, bahraich under modernization project of electrical & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich.
Tender For supply, installation, testing and commissioning of external wiring around outer wall of pump house in pvc casing capping and wiring of long steel tubular pole with aluminum conductor pvc insulated armoured sheathed cable 1100v for 50w to 100w led flood light at required place. all wiring work should be as per is 732 and is 1944. making wiring point for led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for led flood light) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractoratat saryu pump canal, stage-iii nanpara, bahraich under modernization project of electrical & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich