Web Analytics Made Easy - StatCounter

Optical Aggregometer Tenders

Get complete information related to latest Optical Aggregometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Optical Aggregometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Optical Aggregometer Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39418055 Due date: 10 Mar, 202510 Mar, 2025 NA
Tender For supply of 70 degree angle probe 2 mhz single crystal 20 mm dia for weld testing. make: paras [ warr anty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :39442003 Due date: 06 Mar, 202506 Mar, 2025 NA
Tender For supply of 37 degree f&b angle probe 2 mhz single crystal 20 mm with probe shoe and roller assembly.

Central Government/Public Sector

CTN :39442567 Due date: 17 Mar, 202517 Mar, 2025 NA
Tender For supply of normal probe 20mm dia 2.5 mhz, 0 degree single crystal suitable for einstein/ arya ufd machine.

Central Government/Public Sector

CTN :39418058 Due date: 10 Mar, 202510 Mar, 2025 NA
Tender For supply of 0 degree normal probe 2 mhz double crystal 18/20 mm. make: paras [ warranty period: 3 0 months after the date of delivery ]

Central Government/Public Sector

CTN :39417010 Due date: 24 Feb, 202524 Feb, 2025 NA
Tender For supply of tr-0-44, 0 degree probe 4 mhz dual crystal for drt model no.-multiscan dr-18. make/bran d-eec. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :39396283 Due date: 28 Feb, 202528 Feb, 2025 NA
Tender For supply of 70 degree f/b angle probe 2mhz single crystal, 20mm dia with shoe and roller

CTN :39284815 Due date: 04 Mar, 202504 Mar, 2025 NA
Tender For supply and installation of physics instruments - c.r.o. dual trace 40 mhz: 1. type of input channels- analog and digital (mixed signal)2. number of analog channels-3. bandwidth - 300 megahertz.4. display type -colour tft.5. minimum display size- 10 inch.6. time base accuracy- 2.5 parts per million.7. sampling rate per digital channel simultaneously: 1gs/sec.8.record length per digital channel simultaneously- 8m point., function generator 0.3 to 3 mhz (scientific 10 mhz to 25 mhz frequency 1 channel function generator) : 1. frequency bandwidth (sine wave ) 10 mhz to 25 mhz.2. sample rate of arbitrary waveform generator (mega samples/sec)3. amplitude range (at 50 ohm impedance),10mv to 10 v pp. , multiplexers and de-multiplexer with built in power supply :1. material- abs2. display- digital, verification of de-morgen s theorem with built in power supply : 1. type- digital2. consisting of built in power supply3. logic ics connected internally for 1st & 2nd theorem.4. 2 logic input switches with indcators.5. 1 logic output indicator.6. 3 patch chords to connect input and outputs., encoder and decoder circuit with built in power supply : 1. material- pvc2. equipment materials - glass epoxy front panel with pvc3. temperature range- -5 to 45 celsius4. output voltage(regulated) : 5vdc (internally connected) , half adder, full adder, half subtractor, full subtractor with built in power supply: 1. built-in power supply dc +5 v at 500 ma.2. 3 logic input switches with green led display.3. 3 logic output red led display.4. two and gates ( 7408 ), one or gate ( 7432 )two not gates ( 7404 ) & two ex-or gates ( 7486 ) on panel., hall probe method for measurement of resistivity, complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply. (complete apparatus) : 1. hall probe (ge crystal);(b)hall probe (inas).2. hall effect set-up (digital), dhe-213. electromagnet,emu-75oremu-50v.4. constant current power supply, dps-175 or dps-50.5. digital gaussmeter, dgm-102.6. range- 0-20 ma, apparatus to study characteristics of tunnel diode : 1. instrument comprises of dc regulated power supply of 0-600mv.1. two round meter for voltage & current measurement.2. circuit diagram is printing on front panel & important connections brought out on front panel.3. with well illustrated instruction manual, photo diode characteristic apparatus : 1. material- ms2. frequency- 50hz, photo transistor characteristic apparatus : 1. instrument type- analog2. input voltage - 220 v3. frequency - 50-60 hz, solar cell characteristic apparatus (complete apparatus) : 1. analog voltmeter: 12. analog ammeter: 13. solar panel/photovoltaic cell/solar cell to study characteristics: 14. range of dc voltmeter (in volt): 305. range of dc ammeter (in milli ampere): 506. necessary patch cords for interconnection7. along with instruction manual and demonstration, apparatus to study charging and discharging of a capacitor : 1. built in power supply : +12v variable & -12v, variable dc2. mains : 230v ac , ldr characteristics apparatus. : 1. voltage- 220 v2. apparatus type- analog3. temperature range- 50-60degree, plancks constant using solar cell : 1. instrument type- digital 2. built in power supply : +12v variable & -12v3. necessary patch cords for interconnection

CTN :39278454 Due date: 03 Mar, 202503 Mar, 2025 NA
Tender For tender for supply of 35 lines of adges test equipment - step attenuator , bulk head for power sensor , fan , battery nicad , bulk head for sensor , a6 card pwb assembly , oscilloscope probe , smart tweezer , crystal detector , battery info lithium , temp control solding iron , dc power supply , ram , cable assy , ac dc power supply , oscilloscope , ps electrical unit , rubber keypad , rubber keypad hmo , rubber keypad ch flat scope , display w pane , display cable piccolo , lithium rechargeable battery , key pad mat , diplexer 30 ghz , optical attenuator , lc duplex coupler , tdk intverter card , s fdaas cpu card rev c , mouse usb , tft , hard disk point sata with sata hdd housing kit , s fdaas cpu card , sd ram gb ddr mhz , oscilloscope probe

CTN :39249204 Due date: 28 Feb, 202528 Feb, 2025 1.35 Crore
Tender For state-of-art fully digital high end latest color doppler echo cardiology system for adult, paediatric and neonatal application with all quantification software's including contrast study, system must be offered with a minimum of 40 lakh digital processed channels. original technical data sheet should be enclosed in technical bid to support the number of channels on the systems. if not mentioned, please attach a letter from manufacturer along with the technical bid clearly stating the digital processed chan nels of the offered system, system should incorporate latest image acquisition & processing technology maintaining uniform spatial resolution, tissue uniformity through complete fov at high temporal resolution resulting high diagnostic confidence. please attach white paper on this technology, system should have broad band beam former capable of processing signals from 1-16 mhz, high resolution main display minimum size 21 inch with wide viewing angle. lnbuilt 12 inch high resolution touch screen user interface capable of image display and complete image processing & measurements, system, control panel, and monitors mounting should have continuous height and angle adjustment for operator comfort especially suitable for multiple -user depts. with high patient load., system should incorporate facility for high r~solution 2d, m mode, pw, cw doppler color flow imaging, color power angio imaging with high frame rate of min 1900fps for 2d & 200 fps for color imaging, system should have full spectrum imaging, speckle reduction filter, spatial compound imaging, phase inversion tissue hannonic imaging, trapezoidal imaging &contrast enhanced imaging(low-mi), system must be offered with speckle reduction imaging: image processing technique to remove speckles and clutter artifacts., system should have strain quantification imaging, including strain assessment for la, lv and rv, split screen view with independent cine loops & cfm. simultaneous b mode& b color mode., 2 d measurement should include calipers for distance/ depth, angle, areal circumference by ellipse/trace etc, integrated stress echo facility to perform stress echo exams., system should have real time triplex mode facility in 2d, color and doppler modes., system should have dynamic modes of 270db or higher, system should have high prf(mention rate-highest will be preferred), system should have scan depth of i to 40 cm or more. please specify through data sheet, system should have 256 shades of grey display, system should have facility for real time and frozen, pan or point zoom. cine loop as well as cine scroll facility in b mode., system should support single button to customize the workflow of doctor., system should have independent steering ofb mode and color on linear probe, system should have individual operator specific atomized workflow protocol which lets operator focus on patients, dedicated sdd of min 512gb for os for fast boot up and separate hdd for patient image storage min 1 tb, system should include anatomical mode, cardiac quantification software including auto ef, tdi, tdi quantification, and stress and strain., system should have contrast imaging with quantification for lvo study and myocardial analysis, system should include auto imt measurement and preferably based on real time data, possibility to modify/edit patient data during and after exam has been completed., system should min 8 point tgc and separately lgc dedicated cardiac applications, system should include integrated report generation sw included choice of embedded images, systems should have standard minimum 4 active probes connectors with electronic switch facility from key board. it should be provided with following transducers. a. adult single crystal phased array probe 1.5 to 4 mhz b. pediatric cardiac phased array probe 3 - 8mhz c. neonatal transthoracic transducer 4-12 mhz d. 3d tee transducer 2 - 7 mhz matrix! single crystal technology with biplane imaging and mini
 Loading, Please wait...

Connect us via What's Up