Tender For corrigendum : supply of led luminaire for floodlight (v2) conforming to is 10322 (part 5/section 5) (q3) , led batten (q2) , bayonet lampholders (v2) isi marked to is 1258 (q2) , mcb miniature circuit - breakers for a. c. operation as per is / iec 60898 (part 1) (q2) , capacitors for electric fan motors as per is 1709 (v2) (q3) , non - modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular domestic electrical sockets - is 1293 (q3) , electrical plugs (v2) isi marked to is 1293 (q2) , pvc insulated unsheathed cable with flexible conductor as per is 694 (q2) , elecric bells and accessories as per is 2268 (q3)
Tender For tender on turnkey basis for improvement of supply reliability in the areas under electrical division, hpsebl, nalagarh by replacing of existing conductor with htls 100sq.mm and replacing of damaged pcc pole with s/t poles of 11/13 mtr long
Tender For corrigendum : supply of rigid plain conduits of insulating materials as per is 9537 (part 3) (q3) , rccb - residual current operated circuit breakers as per is 12640 (q3) , pvc insulated unsheathed cable with flexible conductor as per is 694 (q2)
Tender For corrigendum : part-a- establishing 2x31.5 mva, 66/11kv substation at kiadb obalapura industrial area in nelamangala taluk, bengaluru rural district. part-b- construction of 66kv over head line by liloing the under construction dabaspete-doddabelavangala line near hadhihosahalli village up to proposd 66/11kv substation at kiadb obalapura industrial area for a distance of about 1.636 kms using drake conductor.
Tender For constructing 11kv covered conductor/abc line using psc poles and installing 100kva transformer at kattakode under electrical section, kattakada of electrical division, kattakada under electrical circle, kattakada
Tender For capital works-renovation works for effective power evacuation from newly constructed 2 mdmr feeder- enhancing the capacity of 110kv bus with triple bersimis acsr conductor at 220kv substation, malaparamba- part-c- stringing of bus
Tender For supply of self ballasted led lamps (led bulb) (v3) conforming to is 16102 (part 2) (under bis scheme - ii) (q2) , led batten (q2) , plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , electrical plugs (v2) isi marked to is 1293 (q2) , mcb - miniature circuit - breakers for a. c. operation as per is / iec 60898 (part 1) (q2) , molded case circuit breakers (mccb) as per is / iec 60947 (q3) , led luminaire for floodlight (v2) conforming to is 10322 (part 5/section 5) (q3) , led luminaire for road and street lights (v2) conforming to is 10322 (part 5 / section 3) (q3) , led luminaire (recessed luminaire) (v3) conforming to is 10322 (part 5/section 2) (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , non modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , piano type non modular domestic electrical sockets - is 1293 (q3) , led bulkhead light (q3) , elecric bells and accessories as per is 2268 (q3) , capacitors for electric fan motors as per is 1709 (v2) (q3) , pvc insulated unsheathed cable with flexible conductor as per is 694 (q2)
Tender For bid to ras corrigendum : supply of c73340415174 supply of high static pressure ductable ac unit capacity 8point5 tr having one indoor and one out door unit refer annexure-iii , 100000000000 supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac units 8point5 tr refer annexure-iii , 100000000001 providing cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor refer annexure-iii , 100000000002 providing of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-iii , 100000000003 supplying of xlpe insulated, pvc sheathed, armoured, copper conductor, 1point1 kv grade lt cable of size 4 core - 6 sqmm refer annexure-iii , 100000000004 supply of xlpe insulated, pvc sheathe, copper conductor, 1point1 kv grade lt cable of size 4 core - 2point5 sqmm refer annexure-iii , 100000000005 supply of 150 mm width x 50 mm depth x 1point6 mm thickness of perforated hot dipped galvanised iron cable tray refer annexure-iii , 100000000006 installation testing and commissioning of high static pressure ductable ac unit capacity 8point5 tr refer annexure-iv , 100000000007 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units refer annexure-iv , 100000000008 laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain refer annexure-iv , 100000000009 laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure-iv , 100000000010 laying of xlpe insulated, pvc sheathed, armoured, copper conductor 1point1 kv grade lt cable of size 4 core - 6 sq mm refer annexure-iv , 100000000011 laying of xlpe insulated, pvc sheathe, copper conductor 1point1 kv grade lt cable of size 4 core - 2point5 sqmm refer annexure-iv , 100000000012 installation of 150 mm width x 50 mm depth x 1point6 mm thickness of perforated hot dipped galvanised iron cable tray refer annexure-iv , 100000000013 dismantling and shifting of existing ductable indoor and outdoor 2 x8point5 tr refer annexure-iv