Tender For nidavanda : proposed construction of s and t service building (one floor over existing station building) and extension of pf-1 for a length of 100 mtr at nidavanda station in connection with additional loop line of road-1a (composite work). maintenance period is 12 months
Tender For alteration in kyosan make e.i at kudra station due to yard remodelling for eliminating the shunting in mainline by provision of overrun line in dn and up loop lines.
Tender For strengthening of existing side pathway and replacement of corroded/perforated m.s chequered plates by stainless steel chequered plates of gang way, side pathway, man refuse and tolly refuse of br. no.-5f, 77,89,132,141,143,152,172 up, 202 up, 206 up in sbg loop and 190 a in main line section of howrah division. & provision of standard bridge boards for major bridges in the section of kan-gman under den/4/hwh.
Tender For corrigendum : supply of indented items required for mrpl spm - spm-tanker loop good rope- 48mm x 8strand-polypropylene- ocimf compliant-in coil of 220m, spm floating hose pick up rope 36 mm 3 strand, spm-messenger line rope-20mm x 3 strand-polypropylene-in coil of 220m, spm-gaint line rope-24mm x 3 strand-polypropylene in coil of 220m, spm-mooring hawser rope- 80mm x 8strand-polypropylene- ocimf compliant-in coil of 150m
Tender For item type: supply of digital multifunction insulation tester having function of fault loop & line impedance measurement range 10 ohm/20 ohm/200 ohm/2000 ohm & resolution .001 ohm/0.01 ohm/0.1 o hm/1 ohm, with rcd testing non trip feature prospective earth fault current, psc test (short circuit measur ement) range 1000a/10ka (50ka) resolution 1a/0.1ka. ac voltage measurement range 500v & resolution .i v insulation resistance measurement (riso) test voltage 50 - 100 - 250 - 500 - 1000 v, accuracy of test volt age (at rated test current + 10% - 0%), test voltage range 50v - 1000 v, insulation resistance range - 20m ohm/50m ohm/100m ohm/200m ohm/1000m ohm & resolution .01m ohm/0.m ohm/1m ohm, input impedanc e- 360 k ohm, over load protection- 660 v ohm ms, test current i ma ( 50 k ohm, 100 k ohm, 250 k ohm, 5 00 k ohm, 1 m ohm, continuity testing (rlo) range (auto ranging) 20 ohm/200 ohm/2000 ohm, open circuit voltage >4v, earth resistance measurement 2 pole & 3 pole with accessories, rcd testing for type ac, ab, & programmable rcd bluetooth connectivity, internal memory for test data storage, rechargeable battery 6xaal (iel lr6) c 1600 hard carrying case, zero adapter, heavy duty mains cord, standard test lead set, p added carrying & waist strap, tp 165x remote control probes. [ warranty period: 30 months after the dat e of delivery ]