Get complete information related to latest Oxygen Face Mask Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Oxygen Face Mask Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Oxygen Face Mask Tenders.
Tender For supply of consumables of cardiac catheterization lab for gbph, sri vijaya puram - puncture needles (adults), puncture needle for vascular access in adults 18 g 6- 7.5 cm long should be compatible with 0.038 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, puncture needle dedicated for radial artery access in adults 20- 22 g 3- 5 cm long should be compatible with 0.021 - 0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for vascular access in adults 20- 22 g 6- 7.5 cm long should be compatible with 0.018 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, micropuncture needle for radial artery access in adults 20-22 g 3-5 cm long should be compatible with 0.021-0.025 inch guide wire should be supplied individually packed needle should have protective plastic tube covering, introducer sheaths (adults), introducer sheath for adults and pediatrics (sizes 4 -9fr.) - standard length sizes 4- 9 fr 10- 11 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath with puncture needle for adults (size 5- 9 fr) - standard length sizes 5- 9 fr 10-11 cm long pack must include 18 g, 6- 7.5 cm long puncture needle 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, long introducer sheath (size 6- 7fr) 20-50 cm long sizes 6- 8fr sheath should be between 20-50 cm long 0.035 or 0.038 inch guide wire compatible with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer sheath for radial access introducer sheath dedicated for transradial access sizes 4- 7 fr between 7- 16 cm long 0.021 - 0.025 inch guide wire compatible pack must include 20-22 g, 3.5 cm long puncture needle with haemostatic valve to prevent back leak of blood and aspiration of air integrated side arm with attached 3-way stopcock with suture eye for securing sheath m coat hydrophilic coating kink resistant with dilator-hub lock mechanism to prevent its back-out during insertion with smooth and resistance free insertion, introducer slender sheath for radial access transradial slender sheath systems 5f 10 cm capable of introducing 6f catheter with hydrophilic coating on sheath ,tapering dilator hydrophilic straight polymer 0.025 wires and 20g plastic cannula for puncture . should be fda/ce/dcgi approved, introducer slender sheath for radial access transradial slender sheath systems 6f 10 cm capable of introducing 7f catheter with hydrophilic coating on sheath, tapering dilator hydrophilic straight polymer or stainless steel 0.021 or 0.025 wires and 22 g / 20g plastic cannula for puncture should be fda/ce/dcgi approved, guidewires (adults), ptfe coated diagnostic guide wire - regular length, regular stiffness should be available in 0.025, 0.032, 0.035 and 0.038 inches size should be between 145- 180 cm long should be available as straight & j shape tip should be available in variable lengths of flexible/floppy end should be available in variable j tip sizes should be available in fixed as well as movable core, ptfe coated diagnostic guide wire - exchange length, regular stif
Tender For supply of angioplasty inflation device 0 to 30 atms with locking switch , diagnostic radial tig radiofocus catheter 5 fr bis and equivalent , disposable primary angiography kit consisting of 1 bowl 250 ml 03 sponge bowl 100 ml 02 surgeon gown 02 trolly cover 02 anigiodrape 01 , us fda pmda eu ce bis approved radial sheath 6f obq 5f , usfda pmda eu ce bis approved femoral sheath 6fr , femoral sheath 7 fr bis and equivalent , device for arteriotomy closure plug mediated for femoral access closure. size 6f or 8f , arterial acess device for complex angioplasties and stable procedure with hyper shaft reinforced 2 nd curved 3rd curved with henka braid provides superior manevurerbility spb rca sc hs im mp , radial artery puncture needle 20 g length 3. 2cm eg. jelco , us fda pmda eu ce bis approved 0. 35 radio focus hydrophilic coated guide wire of super elastic alloy radioapque tungsten in corporated in to the polly , tpi lead balloon tip 5 fr , usfda pmda eu ce bis approved pull push hemostasis valve kit , ptfe coated j tip 0. 035 wire exchange length 260cm 300cm , back table cover large 60 x 90 152cm x 228 cm sterile , ptca guide catheter judkins right 6fr obq 7 fr bis and equivalent , pace pack consisting of sterile drape in control plus fabric reinforcement 87 x72 221cms x 343cm with bilateral fenestrations , pressure monitoring line 100cm 200cm male obq female , 6fr tpi lead , ptfe coated j tip 0. 035 wire normal length 150cm , us fda pmda approveddiagnostic judkins left angiography catheter 6fr , syringe luer lock polycarbonate construction for use with sclerosants etc 10 ml , syringe luer lock polycarbonate construction for use with sclerosants etc. 20 ml , high pressure 2 port manifold , high pressure 3 port manifold , radial and femoral angiography sterile drape in control plus fabric reinforcement 149. 5x 94 380cms x 240cm with dual windows bis and equivalent , pacemaker obq icd after care bandage , special curve angiography catheters amplatz multipurpose ntr etc assorted shapes and sizes , femoral sheath 8 fr bis and equivalent , powder free gamma sterilized nature rubber latex brown operating gloves with textured outer surface and polymer coated dermashieild technology inner surface minimum thikness 0. 3 mm sizes 6. 5 , powder free gamma sterilized nature rubber latex brown operating gloves with textured outer surface and polymer coated dermashieild technology inner surface minimum thikness 0. 3 mm sizes 7. 0 , coronary snare kit assorted size , ultra high pressure opn nc ptca balloon for complex angioplasty , opn id obq inflation device with pressure limit 55bar obq high resolution , c arm drape 41 x 74 104cm x 187cm , sterile gauze with radiopaque marker box of 100 gauze piece , ptfe coated 0. 35 300cm super stiff guide wire eg. amplatzer , printer toner catridge cc388a