Get complete information related to latest Pcc Foundation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pcc Foundation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pcc Foundation Tenders.
Tender For construction of 01 no. pccfoundation for installation of pump in 13d/35l and 36l in johilla bottom seam at birsinghpur colliery (ug mine) of pali sub area, johilla area
Tender For rate tender work for two years as per the terms of tender for supply of spare parts and repair work of tata vehicles/machines of jodhpur municipal corporation north garage branch. water separator opening and fitting , hydraulic distributor opening and fitting work , air compressor head repair , compressor repair job work , engine cylinder head repair , clutch booster repair job work , clutch plateset openingand fitting , pressure plate repairing work , engine mounting work , engine foundation pad opening and fitting , engine opening and fitting , engine over hauling complete job work , cabin mounting opening and fitting , fuel pump complete repair job work , fuel pump calibration , hydraulic pump seal kit and repair work , turbocharger complete repair job work , wheel opening greasing and fitting each , wheel balancing and alignment , shock absorber reapir work , complete nipple greasing , front wheel drum repair each , rear wheel drum repair each , brake liner shoe changing each set , bumper opening repairing and fitting , front leaf pin bush fitting , front leaf shackle fitting , gear top opening and fitting , gear opening & fitting , nozzle repairing work , front leaf opening fitting and tensioning work one side , rear leaf opening fitting and tensioning work one side , new pto assembly opening and fitting labour job , pto gear repair work , radiator opening cleaning and fitting work , coolant (castrol/bpcl/iocl) , universal joint new fitting work , engine service charge (with air, oil, fuel filter and labour work (engine oil will be provided by garage) , silencer opening, repairing and fitting work , fly wheel disc fitting work , coupling shaft thread repairing , radiator fan opening and fitting work , propeller shaft opening, repairing and fitting , hub axle repairing , differential repair minor work , hydraulic/oil pipe repair work , shaft bend repairing work , hydraulic steering repair work with tie rod end fitting , steering gear box assembly repair work , steering gear box assembly fitting work , minor arc/gas welding work , dashboard electronic repair work , all censors checking and repair work , vehicle front fibre repair work minor , vehicle front fibre repair work major , hopper body repairing major work with channel , hopper body repairing minor work without channel , hopper body colour green and blue , tripal cover full on both hopper , hydraulic jack new seal kit and fitting work , engine timing belt opening and fitting work , jack foundation repair work , tape repair work , new tape assembly with wiring , cabin complete repair work with colour , cabin seat repair work complete , door lock work , door glass winding mechanism work , complete door repair work with denting and painting , fuel motor opening and fitting work , any sensor opening and fitting work , self repair minor work , self repair major work , controlvalve minor repairlabour job , alternator repair minor work , alternator repair major work , front glasses opening and fitting , wiring set complete work with labour charge , wiring change minor work , hydraulic/ fuel pipe opening fitting , labour job , regeneration/updation work , turbo pipe/egr opening and fitting work , air pressure pipe replace labour job - ?????? ??? ???? ????? ????? ???? ?? tata ??????/?????? ?? ??? ?????? ?????? ??????? ??? ????????? ????? ???? ?????? ?? ?????? ?? ?????? ?? ???? ?? ??? ?? ?????? ?? ??????
Tender For pccfoundation and support welding at base of ht/lt o/h lines electric pole for making its root mechanically robust at township of rajrappa area
Tender For supply of taking down of light fittings of any type size and model complete all as specified , taking down of brackets of any type size and model complete all as specified , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug , m and l in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , s and f in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f cable junction box 155x210x92 mm in size, made out of thermoplastic having ip 66 protection for outdoor installation fixed with 4 way , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , taking down out unservicable or servicable ug cable of any cross section area and connection etc. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth , returning filling in including spreading, levelling watering and well ramming in layers not exc. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , s and l for cable in trenches or passing through pipe, xlpe insulated 25 sqmm 4 core. , s and l for cable in trenches or passing through pipe, xlpe insulated, heavy duty, galvanised steel strip or wire armoured electric lt cable 10 sqmm 4 core. , re laying fixing or passing through xlpe insulated armored electric power ug cable etc. , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed . , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia under road foot path, not exc. 10.00 mtr , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection and connection of cable. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of taking down of light fittings of any type size and model complete all as specified , taking down of brackets of any type size and model complete all as specified , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , s and f in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing. , s and f in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , s and f cable junction box 155x210x92 mm in size made out of thermoplasti having ip 66 protection for outdoor installation fixed with 4 way bakelite cable terminals , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees bends elbows , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above , m and l sand cushioning dry in trenches for protection of ug cables , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , s and l for cable in trenches or passing through pipe xlpe insulated wire armoured electric lt cable 25 sqmm 4 core. , s and l for cable in trenches or passing through pipe xlpe insulated heavy duty galvanised steel strip or wire armoured electric lt cable a 10 sqmm 4 core. , relaying fixing or passing through pipe xlpe insulated armoured electric power ug cable heavy duty , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection and connection of cable , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of taking down of light fittings of any type size and model complete all as specified. , taking down of brackets of any type size and model complete all as specified and directed. , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts , m and l in repair steel tubular swaged poles complete with cast iron base plate , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , supply and fixing in repair led street light fitting 120 watt 230 v ac outdoor type , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics , supply and fixing in repair led flood light 150 watt 230 v ac outdoor type with thermal management , s and f cable junction box 155x210x92 mm in size made out of thermoplastic aving ip 66 protection , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks gi pipe etc. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified , removing excavated materials soils not exc. 50.00 mtr , m and l sand cushioning dry in trenches for protec tion of ug cables , m and l for fly ash bricks locally available laid dry width wise across the line of cable , supply and laying for cable in trenches or passing through pipe xlpe insulated heavy duty , supply and laying for cable in trenches or passing through pipe xlpe insulated 10 sqmm 4 core. , re laying fixing or passing through pipe xlpe insulated armoured electric power ug cable 10 sqmm 2 core to 25 sqmm 4 core , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete , s and f hdpe dwc double walled corrugated of diameter 25 mm including , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , crimping tools (q3)