Get complete information related to latest Pedicle Screw Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pedicle Screw Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pedicle Screw Tenders.
Tender For corrigendum : supply of epe make spare bladder and accumulator gasket sets as per attached technical specification - bladder for epe asa-1-6-p-3000-n-p-o-xx-sp , gasket set epe asa-1-6-p-3000-n-p-o-xx-sp , bladder for epe asa-1-p- 3000-n-p-o-xx-sp , gasket set for epe asa-1-p-3000-n-p-o xx-sp , bladder for epe asa-2.5-p-3000-n-p-o-xx-sp , gasket set epe asa-2.5-p-3000-n-p-o-xx-sp , bladder for epe asa-5-p-3000-n-p-o-xx-sp , gasket set for epe asa-5- p-3000-n-p-o-xx-sp , bladder for epe asa-10-p-3000-n-p-o xx-sp , gasket set for epe asa-10-p-3000-n-p-o-xx-sp , accumulator charging kit for epe accumulators
Tender For bid to ras corrigendum : tender for supply of glass microfibre thimbles 19x90mm , qualitative filter paper grade-1 46x57cm , whatman glass microfibre sheets , laboratory thermometer(-10 to 110)deg.c , hydrometer range0.800 to0.850 , hydrometer range 1.4 to 1.6 , hydrometer range 1.0 to 1.2 , hydrometer range( 0.8-0.9) , silicon rubber tubing 7 mm in 10 m coil , silicon rubber tubing 5 mm in 10 m coil , rubber aspirator , rubber bladder no.4 , pipette suction bulb for 5 ml pipette , pipette suction bulb for 10 ml pipette , pipette suction bulb for 25 ml pipette , whatman filter paper no.40 125mm dia , whatmen filter paper no.42(12.5cms) , thermometer 0 to 50 oc
Tender For supply of srph429002-spine dual thread pediclescrew: spine dual thread pediclescrew for sing le lock spinal system - used for lumbosacral fixation and stabilisation in spine trauma, degenerative .pedicular screws should have dual threaded mechanism and should be compatible with 5.5mm titanium/cobalt chromium rod . screws should be made up of cobalt chromium and available in sizes of 4.5, 5.5, 6.5 mm diameter and 25-55mm in length . system should have break off plug mechanism. screw should have an angle of not more than 28 degree between the head and b ody. system should be compatible minimally invasive surgical technique . screws should be colou r coded for easy identification. system should be registered with drug controller general of ind ia. system should be iso or bis or fda or ce approved.unit: set. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 la cs ]