Get complete information related to latest Pelton Turbine Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pelton Turbine Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pelton Turbine Tenders.
Tender For providing and fitting of essential items and allied material for snow clearance operation at nathatop sanasar road - supply, testing and commissioning of 48v smps float cum boost automotive battery charger with moveable trolley stand for snow operation at nathatop - sanasar roadgeneral technical requirements for battery charger suitable for 48v vrla type battery1.) type -float & float cum boost charger for vrla type, full wave, full controlled type. 2. ) ratings- 15 a float cum boost for 48v, 150 ah vrla type battery 3. ) ac input- i) voltage 415 vac 10%ii) frequency 50hz 5% iii) phase 3 - phase 4.) d.c.output voltage settings -nominal float fc 48/54.5v (adj. by + 20%, - 5% bc 48/66.5v (adj. by + 2%, - 5%) 5.) output current limit 15a 15a 6. ) power conversion ac to dc by means of three phase full wave, half controlled bridge rectifier consisting of thyristors and diodes. 7.) voltage regulation at bridge output. + 1% of set value for + 10% input voltage variations, 0-100% load variation. 8. ripple voltage less than 3% rms without battery connected. 9. efficiency more than 80% at full load 10. protections (a) input side ac input mccb & elbs with input on/off switch and fuses, contactor (b) output side dc output mccb with output on/off switch and fuses. (c) protection current limit protection, soft start feature, surge suppressor. fast semiconductor fuses for rectifier bridge. (d) control circuit fuses (e) capacitor circuit rectifier hrc fuses. (f) over-voltage cut-back (g) charger over load / short circuit (h) blocking diode 11. controls and switches followings controls and switches are provided in the system 1 ac input source mccbs with interlocking 2 dc output mccb 3 auto/manual float/boost mode selector switch. 4 float and boost voltage variable potentiometers. 5 manual voltage adjustment potentiometer 6 test push button 7 reset push button 8 battery current adjustment potentiometers 9 heater s power supply switch 12. features the following features are provided in the systems: 10 soft start on dc side 11 class-f insulation for all magnetic 12 automatic voltage regulation. 13 automatic changeover from float to boost and vice versa based on current, drawn by battery. 14 filter circuit to eliminate ripple. 15 charger current limit 16 separate battery path current limit. 17 built-in auto phase reversal of operation. 13. meters f.c. b.c. (i)input voltmeter (i) common (ii) input ammeter (ii) input ammeter (iii) output voltmeter (iii) output voltmeter (iv) output ammeter (iv) output ammeter. battery volt meter battery ammeter earth leakage ammeter 14. indications phase on lamps (ii) output on lamp a)phase on lamps (ii) output on lamp. (iii) charger on float led (iv)charger on boost led. 15. annunciation with audiovisual alarms. (i) ac input mains failure (ii) input phase failure (iii) ac under voltage iv) input phase failure v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped xiii) charger over load xiv) earth leakage xv) dc earth fault xvi) alarm supply fuse failure xvii)battery low condition. v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped. note : all the alarms shall be provided through electronic display cards. audio alarm through buzzer, visual indication through 10 mm leds & alarm ackn. / reset and led provision is through push buttons. 16. operating ambient temperature surrounding the panel 00 to 500 c 17. surrounding the panel relative humidity. 0-95% non-condensing 18. panel (i) protective grade (ii) cooling (iii)paint ip 42 natural air-cooled smoke grey of iss-692 shade a) average winding temperature rise over ambient temperature b) insulation class c) insulation breakdown voltage. as per relevant iss. f 3 kv for 1 min withstand. 19. cables 1100 v
Tender For corrigendum : design, supply, installation, commissioning, training of various type of equipments for esdm (electronic system design and manufacturing) of msme training centers located at greater noida, bengaluru, puducherry and idemi mumbai on turnkey basis - decade resistance box , ct/pt calibration system , multifunction calibrator , decade capacitance box , ct analyzer , standard resistors , standard weights (el class) , pippete calibration system , low temperature bath (-80 to ambient degree temperature) , frequency counter , energy meter test system (3 position) , precision temperature stabilised resistance standard (high) , decade inductor box , precision temperature stabilised resistance standard (low) , sound level calibrator , digital power analyser , decade resistance box (4 nos.) , process calibrator , hv divider , decade mega ohm box , standard weights (e2 class) , 6 and half dmm , temperature indicator , time interval meter , temperature indicator with compensation , standard weights (f1 class) , semi-micro balance (upto 200 gms) , tachometer calibrator , standard thermocouple (type s) without compensation , sound level analyzer , standard platinum resistance temperature (prt) detector , precision balance (upto 6.1 kg) , thermo-couple calibartion furnace (300 to 1100 degree temperature) , lcr bridge , humidity measurement probe , dry block calibrator (ambient to 600 degree temperature) , anechoic chamber with radiated susceptbility and radiated emission test system , alltitude test chamber , compact emc tester , environmental chamber , digital pressure controller (dead weight pressure tester) , line impedance stablizing network , harmonics/flicker measurement test system , impulse generator , rf shielded chamber , vibration plus environmental chamber , three phase regulated variable power source , humidity generator, relative humidity , bump/shock test system , heat deflection temperature test set , vibration test system , electronic load , conducted rf immunity simulator , rohs testing lab - inductively coupled plasma optical emission spectrometer (icp-oes) , thermal shock chamber , ac dc current source , ultra precision capacitance bridge , esd simulator , horizontaland verticlal flame chamber , rohs testing lab - energy dispersive x-ray fluorescence spectrometer (edxrf) , single phase regulated variable power source , precision energy standard , rohs testing lab - gas chromatograph mass spectrometer (gc-ms) , ingress of water test system - i set , rohs testing lab - ion- chromatograph (ic) , needle flametest chamber , salt spray chamber , dust chamber , digital storage oscilloscope , defibrillator proof test set , thermostat endurance test set , flexing test apparatus , electrical safety tester , winding resistance meter , temperature recorder , radiation meter , tracking test apparatus , gas detector , cord anchorage test set , digital multimeter (handheld/desktop) , glow wire test apparatus
Tender For corrigendum : providing of calibration services - mechanical, electrical, thermal, fluid flow, glassware; dimension, mass and volume, pressure and vacuum, specific heat & humidity, temperature, gas analysis, pressure, pressure guage and digital meter; nabl labs; buyer premises..
Tender For supply and installation of equipments for district water testing laboratory malkangiri under rwss division, malkangiri in malkangiri district. - supply & installation of equipments for district water testing laboratory malkangiri, digital analytical balance (decimal four places):- weighing capacity: 220 g readability: 0.1 mg pan size: 90mm repeatability: + 0.1 mg linearity: + 0.2 mg adaptation to ambient conditions: by selection of 1 of 4 optimized filter levels, thermo scientific fluoride ion selective electrode (9609bnwp):-units: ppm, ion measurement mode speculations enables ion concentration measurements of monovalent, bivalent, negative and positive ions relative accuracy: ise +/-0.2 mv or 0.05%, whichever is greater range: ise 0 to 19999, resolution: ise other, nephelo turbidity meter:-systronics make, model-132, photodiode detector, range-0-1000 ntu in 4 ranges (automatic), accuracy: +/-3% of fsd in 0-1 and 0-1000 ntu, +/-2% of fsd in 0-10 and 1-100 ntu, hot plate rectangular (ce & iso certified):- material- aluminium, size: 60x45 cm, dimension: 300x450x150 mm with temperature display and mcb protection, all quartz double distillation unit- vertical (ce & iso certified):-bi double distillation water unit 1.5 lph, vertical unit types, built in quartz heater capacity: 7 kilowatt, hot air oven digital:-material:- stainless steel, chamber volume: 100 ltr, temperature range: 50-300 degree celsius, eye wash:-stainless steel emergency shower and eye washer surface mounted, online ups of rating 2.0 kva with battery, digital thermometer with probe:-temperature range: -20 to 1000 c humidity range (rh %): 100%rhhumidity accuracy: 3.5%rh, digital thermo hygrometer:-humidity range (rh %)-0-100% rhtemperature range: -20.00 - 60.00 c, n.b: the amount put to tender is exclusive of gst. the intending bidders should offer their rate which shall be exclusive of gst as per norms. gst applicable onwards contract shall be paid over the bill amount at the time of payment of each bill.
Tender For supply of plastic tarpaulin 15 x 18 feet , moisture absorber 300 gm , register 400 pages , digital humidity meter , water filter , steel pipe 2 inch , steel knob 2 inch , steel chain link