Get complete information related to latest Pharma Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pharma Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pharma Tenders.
Tender For e tender for procurement of kits, chemicals and reagents for two years from the date of award of contract (aoc) and its extension, if required - "rh +k phenotyping glass bead cassettestechnical specification:1.cassttes should contain 6 columns filled with glass bead as filtration media 2.1st column to 5th column should be prefilled with monoclonal antisera such as anti c, anti e, anti c, anti e, anti k respectively and 6th column is 'control' column. 3.peg should be present in the columns as enhancer to increase uptake of antibody 4. assay time should be as per manufacturer's guideline / brochure 5. mixed field reaction /double cell population should be detected " , "ahg poly specific glass bead cassettes technical specification:1. cassettes should contain 6 columns filled with glass beads filtration media 2. all column should prefilled with ahg reagent (anti igg , anti c3d)3. assay time should be as per manufacturer's guideline / brochure 4. mixed filled reaction /double cell population should be detected" , "blood grouping (forward & reverse grouping) glass bead cassettes technical specification: 1. cassettes should contain 6 columns filled with glass bead as filtration media 2. 1st to 3rd colums should be prefilled with monoclonal antisera with a serial of anti a, anti b, anti d respectively and rest 3 colums contain 1 for 'control' and 2 colums for reverse grouping with variable serial.3. peg should be present in the columns as enhancer to increase uptake of antibody 4. centrifugation time should be as per manufacturer's guideline5. mixed field reaction /double cell population should be detected" , "monoclonal antisera for extended rh+k phenotypinganti c technical specification:anti c sera should be monoclonal anti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti ctechnical specification:anti c sera should be monoclonalanti c sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti e technical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti etechnical specification:anti e sera should be monoclonal anti e sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "monoclonal antisera for extended rh+k phenotyping anti k (kell)technical specification:anti k sera should be monoclonal anti k sera should be compatible for conventional test tube method the potency titre of the antisera should not be less than 4." , "panel for antibody 3 cell screening applicable to conventional test tube method and glass bead cassettes technical specification: 1. cell panel should be 2%-5% of rbc suspended in saline 2. cell panel should be compatible with both conventional test tube method and glass bead cassettes of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4. dose depended antigens (like mns, duffy etc) should be present in homozygous as per criteria of antibody screening test 5. cell panel should be compatible for enzyme treatment 6. pack size should be as per manufacturer's guideline / brochure " , "panel for antibody 3 cell screening applicable to gel card technical specification:1.cell panel should be 0.8%-1% of rbc suspended in low ionic strength saline2. cell panel should be compatible with gel card of column agglutination technology for doing antibody screening test3. cell panel should contain rbc with the antigens of extended rh, kell, duffy, kidd, lewis, mns etc blood group system4.dose depende
Tender For procurement of medical consumables items for use by the cardiology department, goa medical college, bambolim - injectable cardiovascular ultrasound contrast agent comprised of lipid-coated echogenic microbubbles filled with octafluoropropane gas or equivalent approved agent (cost comparison will be based on per study cost); in remarks - please detail the dose required per study per the instructions for use, disposable electrodes designed specifically for patient monitoring, disposible electrodes designed specifically for stress testing - please quote only those that are specifically designed for stress testing, disposible electrodes designed specifically for holter monitoring - please quote only those that are specifically designed for holter monitoring, disposable defibrillator patches (anterior and posterior) for use with philips brand defibrillators, disposable radiolucent defibrillator patches (anterior and posterior) for use with philips defibrillators, printer paper roll for philips mrx defibrillator and for efficia defibrillators, thermal printing paper for sony thermal printer used with echocardiography machines (model up/d-897), ultrasound jelly for echocardiography 5 litre pack, ecg thermal printing paper for use with philips pagewriter tc20 ecg machine; philips make only, ecg thermal printing paper for use with ge mac 5500 hd ecg/stress testing machine; ge make only, ecg thermal printing paper for use with bpl cardiart 6208 view plus ecg machine; 80 mm width roll, filter for hamilton ventilator hma anti-bacterial filter, flow sensor for hamilton g5 ventilator, oxygen cell for hamilton g5 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, oxygen sensor medtronic pb840 ventilators, abg machine sensor cassette for radiometer abl 9 machine - 200 tests with 60 days validity with ph, pco2, po2, hct, na, k, ca++, chloride, lactate, abg machine ssolution pack for radiometer abl 9 machine (sp9), ventilator circuits (two limb) for adult patients, non-invasive ventilator face mask, nasal prongs for pediatric patients, normal saline 1 l pouch pack suitable for use with pressure infusor bag, normal saline 0.5 l pouch pack suitable for use with pressure infusor bag, pressure bag with manometer for iv infusion/pressure infusor bag, silk suture sterilized and packed with cutting needle 1.0 silk nw 5062 or equivalent, silk suture sterilized and packed with round body needle 1.0 silk nw 5063 or equivalent, surgical skin stapler with stapler cartridge for pacemaker pocket closure, staple remover, surgical disposible scalpel blade only number 11, surgical disposible scalpel blade only number 15, iodine impregnated antimicrobial transparent incise drape 23 x 23 cm, film transparent dressing with non-adherent pad 3 1/2 inches x 6 inches (9 x 15 cm), packing material for cath lab use 5 cm width x 200 metres roll, packing material for cath lab use 7.5 cm width x 200 metres roll, packing material for cath lab use 10 cm width x 200 metres roll, packing material for cath lab use 15 cm width x 200 metres roll, packing material for cath lab use 20 cm width x 200 metres roll, packing material for cath lab use 25 cm width x 200 metres roll, packing material for cath lab use 30 cm width x 200 metres roll, ethylene oxide (eto) gas cartridge, labelling instrument for packed items for cath lab, printer ribbon for use in labelling instrument l-1 will be calculated for labelling instrument with label rolls (total quantities), label roll for use with instrument quoted for in labelling instrument with built in eto exposure indicator, label roll for use with instrument quoted for in labelling instrument with built in steam exposure indicator, biological indicator for use in eto sterilizer, biological indicator for use with autoclave sterilizer, incubator for use with biological indicators quoted above l-1 will be calculated for incubator with total quantities of biological indicators in above two rows, steri