Get complete information related to latest Planetary Simulation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Planetary Simulation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Planetary Simulation Tenders.
Tender For supply of t&p material under dapoli-i subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For supply of t&p material inder lote subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For supply of t and p to khed subdivision - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For supply of t&p material under dapoli-ii subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp
Tender For supply of t and p material under mandangad subdivision of khed division - pp rope ", pp rope 1", hexa frame with steel blade, megger(5kv), tong tester 3.5 digit, the tong tester shall have the following parameters: a) ac current measurement: 0- 20/50/500/1000 amp b) ac/dc voltage measurement:- 0 to 300 v/600 v. c) resistance measurement: 400 ohms to 4 k ohms., accuracy: i) for ac current 3% reading with, resolution of 0.1 upto 100 a, 1.0 upto 500/ 1000 a. 2632_spec.doc 2 ii) for ac/dc voltage 1.5% reading with resolution of 0.1 upto 100 v, 1.0 upto 600 v. iii) for resistance 1% reading with resolution of 0.1 ohm upto 400 ohms, 0.1 ohm upto 4 k ohms., the meter should have 3-1/2 digits 2000 counts led display preferably with backlit., aluminium folding ladder (7/8 mtr), spanner set 8 - 24 nos double ended ring, adjustable spanner 12", adjustable spanner 6", collapsible ht earth rod for voltages upto 33 kv, taparia 2 in 1 screw driver 905 1, high beam torch led rechargable, come along clamp