Tender For purchase of lab equipments for basic eng dept - purchase of lab equipments for baisc eng dept (physics and chemistry), digital balance itemcode: a001 weight 500g, accuracy 0.01g, top pan. tare function, caliberation- automatic external display type: led., joule s calorimeter itemcode: a005specifications:copper vessel, battery eliminator 3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0 2a), voltmeter (0-5v), thermometer (alcohol), stop clock, ic regulated battery eliminator itemcode: a011specifications:ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., galvanometer itemcode: a012specifications:moving coil type, 30-0-30 scale, unbranded with bhel specification-sensitivitysensitivity, voltmeter itemcode: a013specifications:dc voltmeter; range 0 10 v, analog., ammeter itemcode: a014specifications:dc (0 - 2 amp), decade resistance box itemcode: a016specifications:resistance box 12 month warranty (dial type) -manganin coil- 2 dials, sonometer apparatus itemcode: a017specifications:sonometer with meter scale attached along with knife edge, tuning forks set 256, 384, 512 ranges, hammer, slotted weight - 500 gm each to a total of 3 kg. brass wire (5 m), travelling microscope itemcode: a018specifications:branded travelling microscope 0 200 mm horizontal and 0-150 mm vertical measurement, potentiometeritemcode: a019specifications:it features a 1-meter to 10-meter constantan/manganin wire stretched on a wooden or sunmica baseboard with a millimeter scale. it includes 4mm brass terminals, a pencil jockey for contact, wire options (10 wires), and a typical resistance range of 10-20 ohms, ideal for high-precision voltage measurements., rheostat itemcode: a021specifications:high-grade ceramic tube, oxidized resistance wire, 0.5a 5a, range 10 100 ., deflection magnetometer apparatusitemcode: a022specifications:deflection magnetometer apparatus with compass box and two short bar magnets, digital electronic balance /analytical balanceitemcode: a001/a007specifictions:load capacity: minimum,500 g readability: 0.01 g,linearity: 0.02g,display: lcd/led,tare function: required,top pan typepower supply: 220 240 v,ac, 50 hz, digital tds meter itemcode: a002specifictions:measuring range: 0 9990,ppm resolution: 1 ppm,display: lcdautomatic temperaturecompensation (atc): requiredwaterproof: minimum ip67 protectionpower source: battery, operated (button cell/aaa, digital ph meter benchtop model itemcode: a003specifications:ph type microprocessor/microcontrolle r ph range: 0 14resolution: 0.01 ph,accuracy: 0.05 ph or better combined ph electrode with temperature sensor two or three-point calibrationfacility temperature compensation type automatic display: lcdpower supply: 220 240 v ac, 50 hz warranty minimum 1 year, laboratory heating mantle (knitted glass yarn) itemcode: a004specifications:capacity: 500ml,temperature range: ambient to 350 c energy regulator/control knob:required power supply: 220-240 v ac,50 hz, mortar with pestle itemcode: a006specifications:material: porcelain size: 100 150 mm inner diameter exterior: glazed grinding surface: unglazed, hot plate itemcode: a008specifcations:top plate material: cast iron plate size: minimum 8 inchdiameter power rating: 2000 w temperature range: ambient o 200 c minimum thermostatic temperaturecontrol: required power supply: 220 240 v ac, 50hz., electric bunsen burner itemcode: a009specifications:electrically operated energy regulator/ control knoboperating temperature 800 c body: stainless steel power supply source: corded electric, supplied with a heavy-duty, heat-resistant,earth-grounded, 3-pin power cord (minimum length 1.2 meters). power consumption: between 350 and 500w power supply: 220 -240 v ac, 50 hz, water distillation unit itemcode: a010specifications:output capacity: 4 litres per hour (lph) ph value: 5.5 to 7.0conductivity (raw water distillation):3.0 4.0 s/cm or less glassware material:borosilicate 3.3 glass (pyrex/duran
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
Tender For purchase of renewable energy practical equipments - equipments for renewable energy practices:, rc phase shift oscillator oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram, strain guage characteristics kitac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristics kit input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer input supply: 230 v / 50 hz ac with regulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation. measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter input supply: 230 v / 50 hz ac with regulated internal dc supply unit. measurement principle: buoyancy (archimedes principle) using displacer element. tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement of temperature using pt100 input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath. measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to 150 c (or suitable laboratory range). display unit: digital temperature indicator with direct c display. accuracy: high accuracy with linearized rtd signal conditioning circuit. sign
Tender For purchase of equipments for eee department - 3 phase capacitor bank :* 3-phase capacitor bank * rating: 2 kvar * voltage: 440 v ac * frequency: 50 hz * heavy duty self-healing capacitor units * powder coated ms enclosure * compact panel mounted/floor mounted construction * proper ventilation arrangement to be provided * capacitor duty contactor/switch to be provided * fuse/mcb protection to be provided * discharge resistors to be provided for safety * proper earthing arrangement provided, 3 phase auto transformer starter :* 3-phase variable autotransformer * input: 415 v * output: 0 470 v ac (continuous) * current: 15 a * copper wound, carbon brush type * heavy duty toroidal/core construction * mounted in powder coated ms/crca enclosure * front panel mounted voltage control knob with scale indication * proper insulated terminals provided * floor/bench mounted type suitable for laboratory use * input/output terminal arrangement provided * mcb/fuse protection provided * proper earthing terminal provided * ventilation arrangement for heat dissipation, linear variable differential transformer measurement trainer :* input supply : 230 v ac, 50 hz * type : linear variable differential transformer (lvdt) trainer kit * lvdt stroke length : 25 mm * lcd display provided * digital voltmeter provided for output measurement * potentiometer provided for calibration and adjustment * signal conditioning circuit inbuilt * zero adjustment and calibration facility provided * test points provided for waveform/signal observation * clearly labeled circuit diagram on front panel * proper insulated terminals and safety sockets provided, plc trainer kit :* plc make :allen-bradley / delta electronics / siemens or equivalent* digital inputs : 8 20 nos.* digital outputs : 6 12 nos. (led / relay type indication)* communication port : rs232 / usb / ethernet (if available)* programming method : ladder logic programming* toggle switches for digital input simulation* led indicators for output status indication* analog potentiometers for analog input experiments* proximity sensor interface provided* relay output interface provided* input supply : 230 v ac, 50 hz* built-in regulated 24 v dc power supply* ladder diagram programming software to be provided* compatible programming software license to be provided* suitable for basic plc programming and automation experiments, conveyor arrangement with siren :* input supply : 12 v dc / 24 v dc / 230 v ac, 50 hz* control mode : manual / automatic operation using plc* conveyor arrangement with geared dc motor provided* proximity sensor provided for object detection* start and stop push buttons provided* audio siren indication provided* plc based control and sequencing operation provided* mini conveyor setup suitable for laboratory demonstration* geared dc motor driven conveyor mechanism* smooth belt movement with roller arrangement, digital storage oscilloscope (dso) :* bandwidth: 50 - 100 mhz. * sampling rate: 1gs/s. * channels: 2 (minimum) * power supply: 100v 240v ac, 50-60 hz * automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., * horizontal scale: 5 ns/div 50 s/div or equivalent * vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) * waveform math: +, -, x , , invert, fft etc., * waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. * 7-inch color display or equivalent * input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), on/off control of lamp using solid state relay kit:* type : solid state relay (ssr) trainer kit* control/input voltage : 12 v / 24 v dc or up to 30 v dc* output load voltage : 230 v ac, single phase* load control : on/off control of ac lamp load* solid state relay based switching circuit* opto-isolated input control* built-in ac lamp load* manual on/off switching arrangement* led indication for input and output statu
Tender For purchase of lab equipments for res dept - purchase of lab equipments for res dept, rc phase shift oscillator (iemcode:o001)specifications: oscillator type: rc phase shift oscillator using transistor / op-amp configuration. input supply: 230 v / 50 hz ac with regulated internal dc supply. output frequency range: 100 hz 10 khz adjustable. output: sinusoidal waveform with adjustable amplitude up to 10 vpp. rc network: three-stage rc phase shift network with frequency control arrangement. cro test points: dedicated cro terminals at amplifier output, each rc stage, and final output for waveform and phase-shift observation. protection: over-voltage and short-circuit protection provided. indicators and controls: power on led indication with frequency and gain adjustment controls. accessories: patch cords, circuit diagram., strain guage characteristi cs kit(iemcode:o002)specifications: ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. no rs.10,000 2 table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords, load cell characteristi cs kit(item code: o003)specifications:input supply: 230 v / 50 hz ac with regulated internal dc supply. sensor: strain gauge load cell with suitable mounting arrangement. load range: 0 10 kg. display: digital display for load/output indication. cro / test points: test points provided for observing bridge output, amplifier output, and signal conditioning stages. controls: zero adjustment and calibration controls provided. protection: overload and short-circuit protection provided. accessories: loading arrangement, connecting leads., measurement of tank level using rotometer(item code: o004)specifications: input supply: 230 v / 50 hz ac withregulated internal dc supply. tank arrangement: transparent tank with 30 liters capacity with suitable supporting stand. rotameter range: 0 4000 l/hr calibrated rotameter. flow system: pump, control valves, and piping arrangement provided for continuous flow operation measurement facility: provision for flow-based tank level measurement and observation. display / observation: calibrated level indication with flow monitoring arrangement. test points: output terminals provided for monitoring sensor/output signals. accessories: connecting tubes., measurement of tank level using displacer type level transmitter(item code: o005)specifications: input supply: 230 v / 50 hz acwith regulated internal dcsupply unit. measurement principle:buoyancy(archimedesprinciple) using displacerelement tank arrangement: transparent experimental tank with 30 liters capacity and suitable mounting stand. level range: suitable laboratory-scale level measurement (0 100% tank height). sensor system: displacer type level transmitter with continuous level output signal. display unit: digital indicator for level display in percentage / engineering units. output signals: standard analog output (4 20) ma / (0 10) v provided for monitoring. test points: provided for transmitter output, signal conditioning, and display unit verification. controls: zero and span calibration adjustment provided for setting level reference. protection: over-voltage and short-circuit protection for electronic modules. accessories: connecting cables, piping arrangement, loading medium (water), measurement oftemperature using pt100(item code: o006a)specifications: input supply: 230 v / 50 hz ac with regulated internal dc power supply unit. sensor: pt100 resistance temperature detector (rtd) probe with stainless steel sheath measurement principle: resistance variation of platinum element with temperature. temperature range: 0 c to