Get complete information related to latest Plc Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plc Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plc Panel Tenders.
Tender For supply of service 11 kv ht panel , sf new mineral oil for panel etc , filteration of mineral oil , servicing of existing mv panel , check and rectification of em interlock , calibration relay etc , sf silicagel , sf 32a hrc fuselink , sf 63a hrc fuselink , sf 125a hrc fuselink , sf 250a hrc fuselink , sf led indication lampa 220v ac , sf 0 to 400a ac ammeter digital , sf 0 to 500a ac voltmeter digital , sf 0 to 30 a dc ammeter digital , sf slelector switch vlotage or current , sf operationg handles for sfu cubicle for extg panel , carryout servicing of 500kva ea set as per specification b chck , repair and service of radiator for 500kva ea set , attending air circuit breaker 800a gec make as reqd , servicing of air circuit breaker 800a gec make as reqd , sf 12v 180ah low mtce battery for ea set , sitc 5 kvar app capacitor , sitc 10 kvar app capacitor , sitc 15 kvar app capacitor , sf 6 stage auto power factor corrector reelay in extg panel , sf 400a mccb with handle on off lamp in sheet steel enclosure
Tender For supply of electrical and electronics laboratory setup - rlc resonance trainer kit series and parallel resonance, kit consists of voltmeter and frequency counter, inbuilt signal generator, experiments can be performed with or without oscilloscope inbuilt power supply, maximum power transfer theorem trainer kit maximum power transferred from a source to a load when the load resistance is made equal to the internal resistance of a source. inbuilt fixed dc regulated power supplies : 12vdc, meters, ammeter & voltmeter, required components provided, circuit diagram printed on front panel & all important test points are brought out on front panel power requirement : 230 vac, clamp on meter suitable for min 300 a ac/dc current measurement range: 0.2 to 300 a, accuracy 1.5% ac voltage: mv to 1000 vac, accuracy: 0.75% dc voltage: 30mv to 1000 vdc, accuracy: 0.5% resistance: upto 30 mohm, accuracy: 0.5% capacitance 1 nf to 30 micro f, accuracy: 1% frequency upto 100 khz, accuracy: 0.5% auto hold, max/min, auto/manual, diode, ip20 protection., digital meter: portable table top type, with cabinet and stand, terminals brought out for connections, range: voltmeter:0-750v ac 0-500 vdc, ammeter:0-20a ac 0-20a dc 2 nos each range, electronic energy meter( single phase) 240vac, 20aac, electronic energymeter( three phase) 400 vac, 30 aac, digital multimeter ¾ digit , true rms ac voltage range : 1 mv to 1000v, accuracy < 1% dc voltage range : 10 mv - 1000 v, accuracy < 0.5% ac current range : 1 ma-10a, accuracy < 2%, dc current range 0.01 ma-10a, accuracy < 1.5%, resistance: 100 mohm-60 mohms, accuracy < 0.5% input impedance: 10mohm capacitance: 1 nf – 60 mf, accuracy: < 5%, frequency: 0.01 hz – 10 khz, accuracy < 0.1% duty cycle, temperature and diode test, lcd display with auto / manual range , included accessories: test leads, rubber holster, temperature probe, battery charger 12 / 24v dc, 15 a, digital power factor meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: single phase, 220v ac, 5a, digital frequency meter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 45-55 hz, digital wattmeter, portable bench top type, with cabinet and stand, terminals brought out for connections, range: 220v, 5a ac single phase (2 nos) 400 v, 5a ac, three phase (2 nos), single phase half wave, full wave , fully controlled bridge rectifier / converter design to study to controlled rectifier & observe wave form on cro. meters provided of suitable range, in built power supply. load resistance, controls for phase angle. circuit diagram printed, & test points brought out on front panel. power requirement: 230 vac +10%, 50hz. supplied with patch chords & instruction manual, ups trainer kit input range: 170 to 270 v, ac output (input present): 195 to 250 v capacity: 200 w battery: 12 v / 7 ah, maintenance free, test points for experimentation purpose. panels: input / output / battery / transformer / avr / charger /inverter study of charger study of changeover logic study and working of ups, smps trainer kit input : 110- 230v, output : 12v dc, switching transformer, scr commuation trainer kit two dc regulated power supplies 0-30vdc/150ma & 0-1 vdc/150ma, three meters for voltage & current measurement , scr 2p4m mounted behind the panel, connections of supplies, meters & scr brought out at 4mm sockets., characteristics trainer kit for scr,diac,triac, ujt,igbt instrument comprises of three dc regulated power supplies 0-15 vdc/150ma, 0-50 vdc/150ma & 0-2.5 vdc/150ma, four round dual range meters for voltage & current measurement,ujt, scr, diac, triac & their supportive components mounted behind the panel, connections of supplies, meters & components brought out at 4mm sockets., kit for speed control of dc motor using microcontroller eters (digital) :0-200v dc, 0-500ma dc instrument provided with 1/12 hp dc motor, on board phase a
Tender For auction sale of depot ferrous scrap - 12160ms26k, 98050011, quantity- 62.280 mts. scrap condemned unserviceable ms-ci signal interlocking materials consisting of levers, rods, ms campus rollers of molb, molb weights, molb booms, signal tubular post, roller trestle, stop boards, 33 mm rods, signal arms, gi and ms wires, lc gate pipes, gate structures, ladders, angles, channels, joists, roller stands, electric poles, cable termination box, direct type lever frame, sa 1914 type trays, sm slides, ssi termination rack, control panels, signal booms, boom locks, cable termination rack, adjustable crank, e type lock, cable marker, ground connection rods, fuse unit, power racks, cam path, gear box, signal reverser, ground lever frame, molb, eolb pedestal, telecom charger body, wire adjustment screws, molb compass roller, gate weights, cls tubular post, surface base, nuts, bolts, rounds, turnout wheels, eye joints, point machine covers, clamps, signal buckets, pulleys, d.w.diversion wheel, gate control panel, calling on unit, gear box assembly with clutch, winch, offset brackets, h.p lock, chequered plates, ptb, location boxes, rkt, axle counter coil fixing plate, shunt signals, route arm, route [1 way, 2 way, 3 way and 4 way], ib hut cut parts, ms electrical point detector, junction type route indicator, route indicators, structures, casing structures, ci bases, gear wheels, flats, cable termination base, u- brackets, ci weights of booms, fabricated posts, cls 2, 3 and 4 aspect units, trestle, sge block instrument, y-crank, stands for wheel tension measuring devices of d.w clutch, lock bar clips, drum clock, ec boxes, relay racks, tlj boxes, foundation shoe, ekt, pd clamps, galaxy stand, meeting posts, signal lamp structures, point rods and other similar signal and interlocking scrap material of sorts and sizes, with or without attachments including negligible nf attachments. note: private crane permitted for loading. note- nf attachments are approximately 2 percent of lot quantity. location- bin no- 160, left side of road no- 1. hsn code- 72044900. gst- 18 percent. note- delivery on actual weighment basis only. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery, as per mv act 1988.
Tender For corrigendum : tender for supply of clip on type terminal station , auto change over switch 250a , cam type single pole on-off switch 10amps , 1s160 , triple pole moulded case circuit breaker 100amps , hcos 100a for emergency operation(ex.)if envisaged in sotr , illuminated push button green , cam type selector switch 2p 2 way with off 10a , hrc fuse link rated 100a , fuse link 2amps , helo starting cable with nato end connectors (21 meters) , mccb 630a , type lm 630b , make e , 3 pole mccb 32a -nsx100f , mcb 250a with micrologic 2.2 trip unit(lv431770) , tp mccb rated 50a , single pole nine way without off rotary switch rated 16a , contactor 110a t.p.(contact kit) , aux contact.base block ( 1 no+1nc) for 110-a t.p. , fuse 32a fitting hrc , unshourded pushbutton 1no+1nc with yellow colour lens(pmt1ab , illuminated pushbutton integral led 230v red , add on 1no contact , d.p miniature circuit breaker rated 16a , terminal , conventional fire detection panel 4 zones , on delay electronic timer ac 110-240v having range 1-30s , 230v ac relays 4 c/o with led and base alonwith clamp , tp mcb 63a(c60h 3p 63a c) , ammeter 0-1000a , rm-800a , ctr 1000/5a , 96x96 cl1 acc 900 scale , hrc fuse fittings rated 20a (3nw20nnsf) , hrc fuse link rated 6a(3nwns6) , hrc fuse fitting rated 20a (3nwns10) , insulation monitoring relay 115v 3ph 400hz (vtv-02) , ammeter 0-200a ctr 200-5a , 400hz acc cl-1 , 96x96 rm at 150a , kilowatt meter 120-0-750 kw size 96x96mm , frequency meter 55-60-65hz 440v , size 96x96mm rm at 60hz , 1 watt , 24v dc/ac , led bulb , milky white of e27 thread type , 1 watt , 230v ac , led bulb , milky white , of e27 thread type. , breaker 25a , dp mcb , step down transformer 20kva , 380 230v , 3ph , 50 hz star-delta , smoke detector tester gas bottle - solo , main processor unit , navigation lamp 65w 230v (per yard) , under voltage coil 230 , 50/60 hz , hrc fuse fitting with fuse link rated 4amps , hrc fuse fitting with fuse link rated 2a , 3 pole mccb , 100amps , 36ka , schinder make , phase sequence indicator 50-500v , 96x96mm cl1 acc 900 scale , kw mtr 15-0-150kw , ctr 2005/5a , rm at 80kw , 415v , 3p , 2 ele 96mm , generator protection unit415v , 3ph , 50hz , load sharing unit mv av 380v , 50hz , 3ph , ctr 250 5a , m340-discrete outputs-modicon m340 discrete dc output , indicating lamp integral led white colour , 24v ac/dc , indicating lamp integral led green colour , 24v ac/dc , indicating lamp integral led green colour 230v , contactor 800a dc , 28v coil with 1no/1nc aux. contact
Tender For 24 volts dc smps control panel unit consist of 3 no s ,10 amps 24 volts smps power supply units as per specification 1, input voltage: - 180 v to 260v ac, 2. output voltage: 24 v dc +/-1% regulation cv, 3. output current: -10a constant, 4. protection: short circuit protection, over voltage protection. 5. riple>200 mv/ 6. enclosure: 1.6 mm thick powder coated sheet steel with connected safety accessories, indications & controls with suitable input double pole mcb control in reputed make. 7.suitable for 16w led cat walk/pit lights 8, each panel shall consist of 3 no s of smps unit suitable for pit lights/catwalk lights.