Get complete information related to latest Plug Tester Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plug Tester Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plug Tester Tenders.
Tender For expression of interest for supply, installation, integration, commissioning, testing, training and documentation for state-of-the-art real time digital hybrid control system and electrical winches with servo motor drive
Tender For supply, installation, testing and commissioning of complete lifting system by eot with all allied accessories as per site requirement for tube wells installed at command tank-2, dwarka sub city.
Tender For supply, installation, testing and commissioning of cctv security surveillance system at naya bazar bps under chandni chowk constieucny ac-20.
Tender For supply, installation, testing, commissioning and maintenance of cctv surveillance system at identified sensitive mining areas, check gates and offices under the jurisdiction of the office of the mining office, balasore
Tender For corrigendum : purchase of biomechanical equipments - nord board, it should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connectivity through usb (wired) bluetooth low energy (ble) for ipad & iphone i.e. (wireless connectivity) should provide 4 years warranty on hardware,should be provided with latest upgradable software and free software updates. should have software available in mobile & laptop (desktop) application with cloud analytics platform applications. should have ability to collect data both local i.e. laptop and on ios devices. local software:- for data collection & data analysis locally. cloud software:- for athlete data management and analysis. local (desktop /laptop) software should be compatible with windows 10 desktop applicationios 13 or later application (ipad & iphone). should have ability to collect data of over 10000 athletes or more to choose with simple name search / grouping them. cloud analytics platform for analysis. software (application) must give real time feedback of testing. license must be valid for 4years. cloud software: - should automatically sync all data collected on local mobile and laptop application when connected to internet.o should have a dashboard to see overview of organization s athletes data and different tiles(data indicators) to see athletes within and outside threshold zones. report section:- should have port section to able to compare different groups/athletes on longitudinal data. should have ability to compare same athlete s data over the period. athletes profile:- should have functionality to enter anthropometry (i.e. upper body & lower body measurement). athletes profile should be auto sync to local application and flexibility to move across different groups or teams with in organization and functionality to pick any athlete from large pool (1000 or more athlete). should be able to setup different access to different people i.e. to physiotherapist, sports scientist and s&c trainer within the organization to secure data access.api integration:- should have open-source api code for integration into athlete management system to integrate in ams system. should have software license valid for 4years. wi-fi tablet 64gb, space grey-1year warranty (as provided by oem) - service by customer service of oem only.hsn:8471.training for installation and demonstration shall be provided at olympian balbir singh senior international hockey stadium, sector- 63, mohali, punjab., electromyography (open), the system should be supplied with minimum 16 high speed wireless emg channel with built in imu sensor. should have analog+ digital base station should have analogy output option to facilitate integration with third party hardware and software sensor should have fixed inter sensor delay of 0.5 milliseconds or less sensors should have fixed spacing between electrodes preferably less than 15 mm to avoid motion artifacts and cross-talk sensor contacts should be made up of a metal for better contact and better-quality signal should be supplied with a charging/transmitting station that communicates with sensors to get information on their charging, recording and signal strength sensors, sensor skin interface, cable, power adapter and accessories sensors facilitate emg and imu measurements emg data analysis software for stand-alone usage with live recording of at least
Tender For corrigendum : purchase of sports exercise physiology lab equipments - cardiopulmonary exercise testing system (including treadmill & cycle ergometer) (2 years warranty)(pac), portable telemetric metabolic analyzer for field and laboratory use.metabolic analyzer portable telemetric system for metabolic analysis should have the following specifications:designlatest generation, single body - weather and dust proof to suit our requirement of tough testing conditions. it should operate in standalone, holter and direct connection to pc modes.weight on subjectless than 1 kg including battery and ergonomically designed multi-size adjustable harnesstesting capabilitypulmonary gas exchange (vo2, vco2), vo2 max, sub-max vo2, thresholds (at, rcp), heartrate with hr belt, resting energy expenditure (ree, rmr), indirect calorimetry w/ face mask, substrates analysis (rq, %fat, %pro, %cho)analysis method breath by breathmotion sensorsinbuilt gps, altimeter, accelerometer (3d + 8g range), gyroscope (3d + 2000 o/s range) andmagnetometer/compass (3d + 1000 t range)wireless connectivitywireless data transmission: bluetooth 2.1 + edr class ii (range >900 meters line-of-sight)connectivityusb, audio, heart rate (aux), wireless device interface (bluetooth for integration with compatible optional peripherals like spo2, ecg etc.)data storagestorage: 512 mb flash > 2,000,000 breathsadditional: sd-hc card 32gb/fat32 - internal slot user accessibledisplay lcd: 3.5 lcd transflective colour - high visibility with led-backlit tfttouch-screen: resistive technology, that allows gloves and wet fingersanalysersoxygen: gfc 0-25% range, lifespan approximately 12 months (very easily user replaceable) response time 120 mscarbon-dioxide: digital ndir 0-10% range, response time 100 msbarometer: range -600 to +5500mflowmeter: bi-directional digital turbine ventilation range 0 to 300 l/min powerbattery: rechargeable li-ion smart battery w/ lcd charge status indicator. 2 packs backup battery: embedded to allow main battery replacement during testing without loss of datamain: 100-240v ac/dc adapter, for direct/main power supply and battery charging. essential accessories / consumablesthe system should be supplied with a compatible treadmill and ergo cycle as per specs below. list of standard items supplied and details of consumables including o2 sensor with their life span should be provided. a compatible laptop pc, colour deskjet printer, 3 litre calibration syringe & calibration gas mixture cylinder with regulator should be supplied with the systemquality assurancemust have european ce, us fda and iso certifications. treadmill running machine with user terminal (display & keyboard) stand- alone and remote control with cpet via rs232 running surface: l:170 cm (minimum), w: 65 cm (minimum) maximum possible load: 300 kg (660 lbs) speed range: 0-25 km/h elevation: 0 to 28% reverse belt rotation motor system 3.3 kw, single phase ac motor, maintenance free and brushless power transmission: frequency inverter, poly v - belt, very quiet operation safety arch should be provided with harness of 5(five) different sizes (small to large) safety system: emergency-off safety stop switch (safety lanyard with actuator, pull cord and clip); potential equalization bolt; transformer for potential-isolation from the mains ambient condition: temperature: +10 to +40 degrees c, humidity 30 to 70% display: touch screen display heartrate monitoring: wireless transmitter; the treadmill should be able to interface with well-known compatible metabolic gas analyzer as per standard and custom exercise protocols different programs para control software for pc must have ce certificationergo cycle functional design and excellent stability, load up to 160kg. easy to use saddle, handle bar and pedals speed independent and dependent power control handle bars are easy to change to suit different tests, rotatable by 360 degrees. mechanical/motor-assisted seat adjustment easy to control and calibr
Tender For corrigendum : purchase of biomechanical equipments - isokinetic dynamometer (pac), should be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric , eccentric, concentric , and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees. should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda
Tender For corrigendum : design, fabrication, supply, installation, testing, commissioning with rms 30 kw capacity grid connected roof top solar pv power plant along with net metering system and 6 mtr. solar highmast 2 numbers at ashram school, waruda tq. dharashiv