Tender For tractor engine capacity cc 2858 or above type of fuel diesel vehicle emission compliance bharatstage tremiiia max engine power 39hp engine rp mat maxpower 1800 maximum enginetorque nm 180 engine rp mat maxtorque rpm 1200 power take off pto type transmission maximum pto power hp 36 72 rp mat maximum pto power 1800 operator station 800 engine aspiration system open station engine cooling natural fuel in jection water cooled fuel tank capacity ltrs inline length of tractor body mm 55liter width of tractor body mm 3770 millimeter ground clearance mm 1725 millimeter wheel base mm 410 millimeter size of front tyre with plyrating mm 1960 millimeter size of rear tyre with plyrating mm 6 00 x 168pr track width front mm 13 6 x 2812pr track width rear mm 1280 millimeter tractor transmission system 1360 millimeter number of forward gears setting partial constant mesh type of wheeldrivetwo wheel drive drive axle rear type of steering manual tractor brake dry discbrake type of clutch dry clutch clutch operation single lifting capacity at hitch point kg 1200kilogram turning radius mm 3600millimeter trailer type of trailer semi trailer singleaxle type of platform tipping platform capacity of trailer 5 tonnes type of axle assembly class b axle assembly wheeltrack mm 1500 number of wheels 2 operating pressure 13 8 tipping angle of body indegrees incase of tippingtype 42 5 dimensions overall width of trailers between extreme points meter 1 83 meter overall length of platform 3 05 meter overall height of trailers with tyre inflated from the supporting surface ground to top of platform meter 608 inch overall height of trailers with tyre inflated from the supporting surface 0 915meter ground clearance mm 300 meter construction parameters material used for fabrication of trailer as per clause 5 table 1ofis 8213 latest yes reto reflective marking tapesas per ais 090 yes lighting and lighting signalling device as perais 0 62 yes trailers shall be fitted with rear under run protective yes device rupd confirming to 4812 latest yes trailers shall have service and parking brake as perais 043 nomaximum load transfer from trailer to load toweye of trailer yes 20percent of trailer capacity isi marked ismc channel used for fabrication of chassis and frame mounting on chassis yes no of spring leave splates fitted nos 1 lashing hooks for towing download yes no of hooks 8 type of towing device paintedcolouronthetrailersasper ais 112 red one coat of red oxide and 2coat of super synthetic enamel paint yes the price should include the insurance and registration charges of the vehicle
Tender For corrigendum : purchase of sports physiotherapy lab equipments - focused shockwave therapy, the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high power laser thera, it should have class iv laser solid-state it should have inbuilt protocol for different indications laser wavelength should be 808nm & 980nm for 18w it should provide laser power up to 0.500mw to 18w pick power 18w (808 nm wavelength for 8w & 980 nm for 10w) the unit should have 7 touch screen facility for use the unit should operating mode should be cw (continuous) or pulsed the unit supply with attachments: scanning laser applicator 500-550mw (class 3b) the unit supply with small and large attachments 1cm and 5cm should be provided to cover different areas the unit supply with dila (deep intratissue laser adapter) supply 2 pairs of laser protective goggles to be supplied warranty 2-year class iv laser therapy is a recent modality that is used to treat pain and promote healing of muscular tissue. the class iv deep intratissue laser therapy machine is european ce approved and is clinically proven to reduce inflammation, reduce pain and increase overall range of motion in a short therapy cycle. it is being used widely all musculoskeletal pain conditions, soft tissue injuries and a wide range of other clinical indication cdsceo device registration certificate unit supply with original trolley, combination therapy machine with vaccum, the unit should be 7 colour display with touch panel treatment encyclopaedia electrodiagnostic i/t curve number of built-in programmes 204 number of user programs 150 number of compatible 2 ultrasound heads electrotherapy parmenter 2 channel electrotherapies max constant current inpatients circuit cc mode- 10. galvanic current 40 ma diadynamic, pules, current 60 ma interferential, kotz, current, unipolar sing surge -100ma tens and sp-tens current 140 ma tonolysis 100 ma microcurrents 1000 a max. voltage in patients circuite (cv mode)-140 v treatment timer 30s 60 min. the unit ultrasound head amplitude- max. 8w for 4cm head working in continuous mode the unit ultrasound head max 12w for cm working in pules mode ultrasound therapy parameter operation frequency- ultrasound head with acoustic working frequency of 1mhz & 3.5mhz with the effective radiation area 4cm effective radiating area- 4cm max ultrasound intensity -continuous /pulse mode 2/3w/cm frequency in pules mode- 16 hz/48 hz/100 hz 24. duty factor in pulse mode 5-75%, step 5% thermal effect 2-year warranty ce european or fda usa certified with iso medical device certifications cdsceo device registration certificate unit supply with original trolley and gel bottle stand and vacuum cup stand with electrode, low frequency electro magnetic therapy, 7 colour touchscreen peration mode: program/manual a sensory indicator of the magnetic field activity- magnetic stripes treatments in dual mode setting the frequency range of the magnetic field with an accuracy of 0,01 hz using the on- screen keyboard illustrated encyclopa
Tender For corrigendum : supply of sch viii (supply of needle & syringes) - sch viii (supply of needle & syringes), disposable needle sterile length 1/2" guage 25, suture needle, half circle triangular nos. 2 to 20 (cutting), insulated needle for use with peripheral nerve stimulator 22g x 2" x 50 mm., insulated needle for use with peripheral nerve stimulator 22g x 35 mm., insulated needle for use with peripheral nerve stimulator 24g x 1"x 25 mm., echogent needles for usg guided peripheral nerve blocks 20g / 21g x 100 mm., echogent needles for usg guided peripheral nerve blocks 22g x 50 mm., epidural needles 16 & 18 guage 7.5cm to 11cm (disposable), epidural needles (long length) 18g (more than 100 mm. length), sterile disposable lancet size 28-32 (plastic lancet needle type), sterile disposable hypodermic plastic syringe 20cc, cn. with leur lock, hypodermic syringes,disposable sterile, sterile pack,with/without leur lock, hub 1ml syringe with marking at 0.1 ml, asepto syringe 100 ml of heavy plastic barrel and rubber bulb with marking., bag arm rubber with cover for b.p. apparatus, adult size velcro.rubber bag size 13 x 23 cms., keratome, size 2.8 mm, type-regular(ophthalmic), angle-45 degrees, bevel type- bevel up (pointed)blade-stainless steel/carbon steel,handle- polycarbonate, use- disposable single use, mvr, gauge 23g type-regular(ophthalmic), blade-stainless steel handle- polycarbonate, use- single disposable use, triple lumen catheter 7.5fr with 14g distal lumen, length-15cm. kit contain 1 teflon-coated j nitinol guidewire particularly kink-resistant with guide-advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18g, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short iv cannula, double lumen subclavian/ jugular catheter kit (adult) ptfe (teflon) cannula curved od 2.7/d 11.5fr-12fr/chx5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s clamping extension, clamp luer lock "y" connector with protective caps size 12.5, 15 with guide wire introducer needle, dialator , 3fr double lumen cvc catheter with 60mm double-lumen polyurethane central venous catheter inserted by seldinger technique, radio opaque material for catheter, the user should be able to choose from 2 type of introducer, i.e.needle 23g or i.v. cannula 22g, latex free, the central venous catheter set should contain: 1 double-lumen polyurethane 3fr catheter, 1 short i.v. cannula 22g, 1 introducer needle 23g, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1.5 ml syringe, peripherally placed radiopaque central single lumen catheter. guage 14/16 (100%) (needles size/catheter size) length - 55cm - 70cm, peripherally placed radiopaque central single lumen catheter. guage 18/20 (100%) (needles size/catheter size) length 30cm - 45cm, fully radiopaque pur catheter 16g for femoral artery centimeter marking from 5-15cm, winged hub for skin fixation, supple distal tip. kit should contain 1 pur catheter with xro lines,1 puncture needle, 1 j guidewire with wishbone-type guidewire advancer, 1 dilator, radial/femoral arterial pe catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.catherter size g- 18, length 10cm, radial/femoral arterial pe catheter 20g, 8cm puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). the needle is also fitted with a silicone bloodless system valve to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire, peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leur connector at proximal en
Tender For corrigendum : supply of fire department equipments d d - foam compound , automatic fire alarm , scba breathing appratus , chemical suit , pneumaticliftingbag , water bowser
Tender For providing of annual maintenance contract of integrated security and surveillance system - personal protective equipment detection solution; comprehensive; hardware, software, networking system, license; consumables to be provided by service provider (included in the contract cost); indu..
Tender For a) scope of work covers supply, installation and commissioning of total 12 nos.of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 with required pcs, electronic modules, splitters, modems, junction boxes, mounting kit, enclosures, interconnecting cables, software and all other accessories required to make the system complete and fully functional, shall be provided for continuous level measurement and monitoring of level of each coal bunker and also to ensure satisfactory performance of the system commissioned at rtps site which shall be on the basis of single point responsibility, completely covering the activities and services in respect of all the equipment works specified and covered under the specifications. the work involves i) installation and commissioning of 12 nos. 3d radar level type level transmitters with suitable mounting accessories, display indicators, isolators, annunciator, smps, terminals, panel internal wiring, led bulbs, door switch etc. at the bunker level ii)commissioning of rs 485 communication /other cables from bunker level transmitters to the desktop pc at u-5&6 control rooms.iii)commissioning of desktop pcs for 3d multi vision for monitoring of all the 12 bunkers level at u-5&6 control room respectively and also both units bunker levels at pc being installed at chp control room. iv)loading of all the required licenced software to the desktop pc for 3d radar level transmitter and cable routing, glanding, mounting of cable tray, termination and ferruling is in the contractors scope.cable trays will be provided by m/s.kpcl.b)all fabrication works required for installation and commissioning of instruments with jbs,protective cover/canopies and allied works are in contractor/agency scope itself.c) all civil works like drilling/cutting rcc floors,grouting,refilling floors,conduiting under ground cables cable tray mounting, masonary works are in contractor/agency scope itself.d)storage of materials while executing works is single point responsibility of contractor/agency scope itself. e)software details-1. the page containing all bunker level data shall be in full page which must be visible from at least a distance of 6-8mtr .(font size should be more) and shall have a historical trend storage for minimum 45days & real time trend with not less than15min sampling time. f) at chp control room, the existing kpcl pc shall be enabled with bunker level software & shall be communicated through existing lan and as a redundancy the seperate optical fiber cable communication with media convertor has to be provided.the lan cables has to be protected with cable conduit g)materials supply shall be completed in all respect within the stipulated period as per the contract. materials shall be delivered to rtps site through ee(stores)o&m. unloading of materials at rtps site location and shifting of the same to work location is under the contractor/agency scope only. h)handling, shifting, unpacking and erection and commissioning of the entire system shall be under the scope of bidder itself. i)all required consumables, hardware and licenced software, accessories and any other materials which are not included in the scope and required for successful installation and commissioning of the 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit-5&6 are under the contractor/agency itself. j)all the materials required for the installation and commissioning of 3d radar level transmitters for the coal level measurement in raw coal bunkers of rtps-unit- 5&6 shall be made as detailed under the technical specifications. k)interfacing of all the bunker level transmitters outputs to the desktop pcs at u-5&6 control rooms through rs - 485 communication protocol.(the required 1 pair x 1 sq.mm shielded armoured cables as per requirements shall be supplied approx-500 meters or if more). for more details of scope of work refe