Get complete information related to latest Pole Foundation Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Foundation Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Foundation Tenders.
Tender For supply of 20 mtr high mast light , steet light controller , led light , construction and foundation work , erection work with testing and commissioning
Tender For tender for supply of training items - pole specification diameter minimum 5inch height above g l 2 59 mtr depth below g l 90mtr distance between 02 vertical pole in same row 1 80 mtr distance between 02 vertical pole in adjacent row 11 00 mtr total nos of pole 06 nos in each row & total 12 nos in both row supporting material each vertical pole should be supported by 3 nos 40 x 40 x 4 mm ms angle inclined length for 02 nos long length has at least of 3 10 mtr & for 01 no short length support should be at least 1 80 mtr joined with 40x40x4 mm ms angle angle should be embedded in ground by 1 2 4 1 cement 2 coarse sand 4 coarse aggregate 20 mm size position cement concrete polefoundationpole should be embedded in ground by 1 2 4 1 cement 2 coarse sand 4 coarse aggregate 20 mm size position cement concrete upto minimum depth of 0 90 meter with anchorage at bottom finishing iron work should be finished with enamel paint as required after application of metal primer to give an even & smooth shade as required base specification height above g l brick base of dimension 10 50 x0 75 x0 75 mtr height below g l brick base of dimension 10 50 x0 75 x0 45 mtr foundation 1 4 8 1 cement 4 coarse sand 8 coarse aggregate 20 mm size position cement concrete below base 10 50 x0 75 x0 10 meter finishing outer surface of base above g l should be plaster with 15 mm thick 1 4 1 cement 4 fine sand & finished with exterior paint finishing enamel paint on iron work & exterior paint on brick base color as required rope specification manila rope having circumference 102 mm minimum length of main horizontal rope pully to pully is 11 00 mtr with end support length 2 55 mtr height 02 nos vertical rope on each horizontal rope total nos of vertical rope 2 x 6 12 nos other requirement pully system for rope on top of each pole hook for rope support ground should be clear & leveled abbreviations g l ground level dia diameter mtr meter , inclined pole specification inclined support 08 nos ms channel 5 x2 5 x6 mm having total 4 05 mtr minimum length & should be embedded in ground by 1 2 4 1 cement 2 coarse sand 4 coarse aggregate 20 mm size position cement concrete horizontal pole specification dia 100 mm ms round pipe medium qty & length total 02nos 3 05 mtr long on top 01no for each side total 1 x 2 2 nos distance between horizontal pole 11 00 mtr finishing iron work should be finished with enamel paint as required after application of metal primer to give an even & smooth shade as required rope specification manila rope having circumference 102mm minimum length of rope is 18 00x2no 36mtr other requirement guest plate in both side of horizontal pole to support welding & fitting accessories ground should be clear & leveled abbreviation g l ground level dia diameter mtr meter , size outer size from pole to pole 6 40 x 6 40mtr side & roof accessories opened from sides & covered on roof with 0 50mm thick 120gm zink coated pgi sheet roofing with self screw or j hook 500 600mm wide ridge of plain sheet on top roof should be extended at least 0 90mtr from vertical pole in each side with complete accessories 04nos ms channel 5 x2 5 x6mm top purlin on vertical pole as tie beam in 04 sides ms hollow pipe 3 x1 5 x5mm in top runner & truss part as per drawing pole specification diameter of vertical pole minimum 5inch height above g l of vertical pole 7 65mtr depth below g l of vertical pole 0 90mtr distance between 02 vertical pole in same row 6 40mtr distance between 02 vertical pole in adjacent row 6 40mtr total nos of of vertical pole 02nos in 01 row & total 04nos in both rows supporting material each vertical pole should be supported by 01no medium 3inch dia ms round hollow pipe of minimum 6 50 mtr length it should be properly embedded in ground by 1 2 4 1cement 2 coarse sand 4 coarse aggregate 20mm size position cement concrete with anchorage at bottom finishing iron work should be finished with enamel paint as
Tender For supply at site, testing of 5mtr. polygonal/octagonal gi lighting mast /pole with double arm pr ovision for lighting purpose, as per dimension top dia - 70mm, bottom dia- 130mm, thickness-4mm, base plate-220x220x12 mm, pcd-220mm, foundation bolt- m16x 600x4, all material should be of is tolerance with all necessary accessories to complete the work in all respect. cost includes cost of power supply arran gement including wiring and necessary reliable protective device (if required) as per site requirement as ad vised by railway site incharge. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of highmast wz and cz - fab and sply of high of 17m of inland sites , const foundation of high mast of 17m of inland sites , instln and commng of high mast of 17m of inland sites , transpt of high mast of 17m of costal sites , fab and sply of high of 17m of costal sites , const foundation of high mast of 17m of costal sites , instln and commng of high mast of 17m of costal sites , transpt of high mast of of 17m costal sites , fab and sply of high of 22m of inland sites , const foundation of high mast of 22m of inland sites , instln and commng of high mast of 22m of inland sites , transpt of high mast of 22m of costal sites , fab and sply of high of 22 m of costal sites , const foundation of high mast of 22m of costal sites , instln and commng of high mast of 22m of costal sites , fab and sply of 17m , const foundation of high mast for 17 m , instln and commng of high mast for 17 m , transpt of high mast for 17 m
Tender For corrigendum : ca no. ge (af)/sgr-60/2024-25 provn of high mast light at 45 weu mt section, pcc foundation for two, four and six pole structure and three phase power supply, geysers, 02 nos ac, ceiling fans and exhaust fans at certain locations under ge (af) srin