Tender For corrigendum : supply of 6 fr highly flexible intracranial support catheter for aneurysm coiling , cerebral protection wire 0point014 inch 150 cm with debris capture at , dual marker microcatheter approved for intra cranial use and , evoh co polymer opacified for embolisation onyx concentration , flow modification device for intracranial aneurysm therapy , microcatheter braided two to tip marker steam shapeable tip , microcatheter steam shapeable tip suitable for catheterisation , transjuglar intrahepatic porto systemic shunt tipss set , flow divertor with atleast 46 72 nitinol strands with balanced porosity , vascular plug assorted sizes with all accessories ce fda approved , 2point1 1point7 f echelon 10 neuromicrocatheter nitinol braiding , intra cranial dual marker braided micro catheter approved for , intracranial dual lumen extracompliant balloon compatible , rf ablation electrode bipolar for ablation zone upto 5 cm of , flow guided microcatheter for super selective catheterisation , torquable hydrophilic microcatheter set of 2point4 2point7 fr of distal outer , transjugular biopsy set complete , distal embolic protection device filter type , self expanding nitinol stents for carotid angioplasty assorted sizes , microcatheter braided steam shapeable tip , 6 fr highly flexible intracranial support catheter for aneurysm , cerebral protection wire 0point014 inch 150 cm with debris capture , dual marker microcatheter approved for intra cranial use and aneurysm , evoh co polymer opacified for embolisation onyx concentration to , microcatheter braided two to tip marker steam shapeable , microcatheter steam shapeable tip suitable for catheterisation of , flow divertor with atleast 46 72 nitinol strands with balanced , intra cranial dual marker braided micro catheter approved , intracranial dual lumen extracompliant balloon compatible with , rf ablation electrode bipolar for ablation zone upto 5 cm , self expanding nitinol stents for carotid angioplasty , microcatheter braided steam shapeable tip suitable for catheterisation //bid details 2 / 39
Tender For supply of intra vascular lithotripsy balloon for coronary angioplasty assorted sizes , 60 mhz coronary imaging catheter with bioslide hydrophilic coating 0 point 026 e ntery profile 15 mm d istal marker to transducer point , cutting balloon with balloon mounted atherotomes assorted sizes bis and equivalent , usfda pmda eu ce medical bis approved rota link plus advancer burr assorted sizes , usfda pmda eu ce medical bis approved rota wire floppy , usfda pmda eu ce medical bis approved guide extension catheter device with hydrophilic caoting ans stainless steel collar embedded in polymer mother child catheter guideliner point , usfda pmda eu ce medical bis approved finecross microcatheter distal diameter 1 point 8 fr proximal 2 point 6 fr of length 150 cm , coronary stent graft system , goose neck microsnare kit , amplatzer asd devices assorted size bis and equivalent , amplatzer compatible asd device delivery system bis equivalent , mullin introducer sheath with radiopaque tip and dilator set assorted sizes , 6fr tpi lead
Tender For e-tender for the supply of various implants and consumables for department of cardiology of r.g. kar mch - temporary pulse genarator - single chember with patient cable(rates for each sub item must be given, cummulative lowest bidder will be treated as l1 bidder), temporary pulse genarator - single chember, patient cable for temporary pulse genarator - single chember, carotid balloon, close tapered carotid stent, single size distal protection device, bmv ballon with set, conduction system pacing - assorted sizes(rates for each sub item must be given, cummulative lowest bidder will be treated as l1 bidder), lbbb lead for conduction system pacing, his sheath for conduction system pacing, slitter for conduction system pacing, coronary snare system, guide extention catheter, amplatz super stiff wire - ptfe coated, distal spring coil, 260cm, coronary cover stent, long sheath - assorted sizes, peripheral angioplasty balloon - assorted sizes
Tender For empanelment for the supply of cathlab items on running contract basis under kasp and other schemes of this hospital - coronary stents, des,everolimus,fda/dcgi/ce approved platinum chromium platform,polyvinylidene fluride-hexafluropropyline pvdf-hfp polymer-stent lengths8,12,16,24,28,32. stent diameter 2.25*,2.50,2.75,3.00,3.50,4.00.struct thickness 81/86 microns.nominal pressure - 11 atm,rated burst pressure 16-18 atm, des,everolimus,fda/ approved platinum chromium platform,polyvinylidene fluoride-hexafluropropylene(pvdf-hfp)polymer, des,everolimus,fda/dcgi/ce/ approved platinum chromium platform,bioabsorbable polymer plga, everolimus eluting platinum chromium stent system, des, everolimus, l 605 cobalt chromium with hybrid cell design , strut thickness- 65microns, polymer- plga diameter- 2.25, 2.5, 2.75, 3.0, 3.5,4. length- 10,13,15,18,20,24, 28, 32,36,40, 42, 44, des, everolimus, cobalt chromium strut thickness - 63 microns . diameter- 2.25,2.5,2.75,3,3.5,4. length- 8,10,13,15,18,20,24,28,32,36,40,42,44. elutes 80% of drugs along with re plga polymer in the first 20 days, dcgi approved everolimus drug eluting 65 micron strut thickness with 3 micron plla&plga. a unique proprietory coating technology basedbiodegradable polymer stent with open cell designed and flexia finished technology based cobalt chromium l605 stent.a designed for optimal strength, flexibility ,trackablity ,side branch supported,bifurcation supported and high radial strength and optimal radiopacity and excellent vessel supported stent with revers alternative link design(ral) stent, with length from 8 mm to 52 mm and diameter from 2.25 mm to 4.50 mm, ce approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., ce approved sirolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 degree with respect to different diameter. the cells are connected by link (mid to mid pattern) with a radius of 0.2700mm. these values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. components - drug: everolimus, stent platform: cobalt chromium l605 alloy, polymer: biodegradable, catheter: ptca rapid exchange semi-compliant stent delivery catheter. drug concentration: 1.2 microgram/mm2 of stent surface area. stent diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & stent length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 platinum-iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, also the difference between stent edge to marker is 0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty., only dcgi approved everolimus eluting coronary stent system struts/cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. the cell angle is between 42 degree to 57 deg
Tender For supply of ptfe angiography guide wire 0 point 035 x 150 cm j tip , terumo angiography guide wire 0 point 032 x 150cm , tiger transradial coronary diagnostic catheter , pacemaker drape with absorbent fabric reinforcement and 2 adhesive fenestrated pockets 6 x 8 , high pressure 2 part manifold , angioplasty kit insertion tool y adaptor and torque device , judkins right angiography catheter assorted sizes , judkins right angiography catheter assorted sizes , inflation device indeflator kit for angioplasty , semi compliant ptca balloon catheter with hydrophilic coated with corrugated surface and low profile wig shaped design 1 mm to 4 mm , ptca guide catheter judkins assorted size , nicorandil 48 mg inj , ebu guide catheter 6f 3 or 3 point 5 , femoral introducer sheath 10cm with patent unique cross cut design haemostatic valve 18g puncture needle with metalic wire , quik combo pacing defibrillation ecg electrodes , glide sheath 5 or 6 or 7 f , ioban antimicrobial incise drape , lignocaine hcl solution 2 percent for iv use 50 ml inj , introducer sheath set with atraumatic tapered tip enalarge inner diameter and lubricant coating radial shealth
Tender For supply of category vi cardio and interventional radio consumables - intra vascular lithotripsy balloon for coronary usage in highly clacified lesions,assorted sizes, sirolimus coated balloon,phospholipid carrier to avoid drug shedding,nanolute technology,100% balloon surfece technology,low crossing profile,assorted sizes, ptca guide wire with tip load 0.8gm and spring coil length 20 cm and one piece core wire with joint less spiring coil and slip coat (hydrophilic coating) over the 20 cm spiring coil, ptca guide wire length 180 cm with tip load 1.0 gm with polymer sleeve length 22 cm with slip coat (hydrophilic coating) and one piece core wire with joint less spring coil., ptca guide wire with tip load 0.8 gm and polymer sleeve length 16 cm with slip coat (hydrophilic coating) and diameter of wire 0.014 inch with tapered tip of outer dimeter 0.0009 inch (0.23mm)., cto ptca guide wire length 150 cm with tip load 1.7 gm and micro cone tip for superior penetration and composite core contruction with multiple wire components., inflation device (indeflator) kit for angioplasty ., high pressure 2 port manifold., angioplasty kit (insertion tool,y adaptor and torque device)., coronary control syringe with ring plunger grip 12 ml., inoue percutaneous transve-nous mitral commissrotomy balloon complete with accessories sizes-26, ptca guidewire with tip load 0.5 gm and silicon coating on distal 1.5cm and slip coat (hydrophilic coating) of 18.5 cm after silicon coating from the tip 1.5 cm with composite core contraction with multiple wire components comprising of rope coil and twist wire mounted on the core wire.