Tender For corrigendum : ktps-v- cam- repair and re-conditioning of semi gantry crane 5ton hoist along with two travel break shoes with gear boxes at cwph.-reg
Tender For the repair overhauling and rectification of draft tube gates 2 nos and the complete overhauling testing and commission of the draft tube gantry at the 3x42 mw lhep for the year 2026 27
Tender For corrigendum : providing of facility management services - lumpsum based - construction of toilet gate area filling and interlocking gantry shifting with 5 ton motorized chain hoist scrap room door installation shed repair and strengthening and boundary wall construction at wor..
Tender For annual percentage rate contract on mes ssr 2020 for civil maintenance/ repair works of traverse, toe wall, drain and gantry including other connected works in filling area inside at ofk.
Tender For work of design, supply and installation of prefabricatedsteelbuilding to serve as a restroomand store for gang and stationary watchmen near bridge at km 252/22-24 adtp-tata section dn line 3rd line as annexure a enclosed. bidders should comply annexure a. [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - wt-5155g - (mmd hps) - work of overhauling / servicing of gear box, & rail alignment of gantry crane having 25 t capacity for dt gate of 4 x 75 mw units, hps, ukai; over..
Tender For premansoon repair and maintenance of electrical equip./control panels of radial crest gates, 100t gantry crane, intake sluice gates, gallery, d.g.room, illum. work for upstream side of radial gates, street light pole/junction box from gallery entrence to ch8 lbmc naka
Tender For providing of custom bid for services - ---- custom bid for services - revalidation of fall arrestor at hpcl kanpur terminal- annual maintenance and revalidation of fall protection system installed at tlf gantry (16 lines), calibration shed (1 line), sealing tower (4 lines), ethanol u/l gantry (2 lines) and tw gantry, spur 1 (14 sections of 50 mtr each and tw gantry, spur 2 (14 sections of 50 mtr each). i. conduct a thorough inspection of the existing fall arrestor system and lifeline. ii. assess the current condition of all components, including harnesses, lanyards, anchors, and connectors. iii. identify any wear, damage, or defects that could compromise safety. iv. ensure the system complies with the latest safety standards and regulations (e.g., osha, ansi). v. verify that all components meet manufacturer specifications and industry requirements. vi. perform load testing on the lifeline and anchor points to verify their strength and reliability. vii. conduct a drop test to ensure the fall arrestor system functions correctly. viii. provide certification of revalidation, including test results and compliance documentation. ix. carry out necessary maintenance, such as lubrication of moving parts and tightening of loose components. x. repair or replace any damaged or worn parts to restore the system to optimal working condition. xi. document all repairs and replacements made during the revalidation process. xii. recommend and implement any necessary upgrades to enhance the safety and performance of the system. xiii. install additional safety features if required, such as shock absorbers or retractable lifelines. xiv. prepare a detailed report of the revalidation process, including inspection findings, test results, and maintenance performed. xv. maintain records of all certifications and compliance documents for future reference. xvi. schedule follow-up inspections to ensure continued compliance and safety. xvii. offer ongoing technical support and assistance as needed. xviii. lifting tools & tackles: vendor should get revalidation certification through a up factory competent person and submit all required documents to hpcl.