Web Analytics Made Easy - StatCounter

Prefabricated Structure Scrap Tenders

Get complete information related to latest Prefabricated Structure Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Prefabricated Structure Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Prefabricated Structure Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42489562 Due date: 13 Dec, 202513 Dec, 2025 NA
Tender For bid to ras corrigendum : supply of shamiyana complete set without structure pole

Central Government And Public Sector

CTN :43128155 Due date: 17 Dec, 202517 Dec, 2025 1.74 Lacs
Tender For providing, installing and painting 3.00 m high four pole structure and cable tray with gi sections and antistatic pvc flooring inside proposed bts room at bhathubasti-iv, sri vijayapuram under ph-ix.2.

State Government

CTN :43141759 Due date: 26 Dec, 202526 Dec, 2025 23.19 Lacs
Tender For ozat-2 w.r.p. repairing of syphone cum canal escape and cart track nr.ch.11306.30 in anandpur main canal & renovation of syphone aquaduct structure in anandpur main canal @ ch.10541.00 mt & canal dgps survey and boundary pole fixing in anandpur main canal and bodaka branch canal.(second attempt)

CTN :43142109 Due date: 19 Dec, 202519 Dec, 2025 NA
Tender For procurement of 600 sets of transformer structure clamp for 9m psc pole double pole structure to tirunelveli region as per specification

CTN :42933062 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For bid to ras tender for supply of job order for urgent repair of transformer of cap 400 kva at mil stn kalka : : - disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed

Central Government/Public Sector

CTN :43109831 Due date: 30 Dec, 202530 Dec, 2025 38.30 Lacs
Tender For special repairs / replacement of ht ug cable and allied work from ciw css to cice 2 pole structure under ge (north) bangalore

Central Government/Public Sector

CTN :43112519 Due date: 22 Dec, 202522 Dec, 2025 35.00 Lacs
Tender For repair /maint of transformer, ht cable, vcb, acb, 4 pole structure panels and connected e/m items at est no 22 area of age (i) chakrata under hq cwe dehradun

CTN :43118112 Due date: 16 Dec, 202516 Dec, 2025 5.29 Lacs
Tender For maintenance of electrical installation for day to day operation of dg set, pump set and maintainance of external and internal electrical installation at ncc nagar chandrasekharpur, bhubaneswar, odisha during 2025-26. (sh: servicing and repairing of existing 2 nos. 250 kva oil type transformer, 01 no 4 pole structure 01 no. dp structure etc.

corporations/Associations/Others

CTN :42721109 Due date: 16 Dec, 202516 Dec, 2025 2.21 Crore
Tender For corrigendum : manufacture, fabrication, supply,erection, testing and commissioning with 1x8 mva pr.tr,stn transformer, associated equipments, accessories, control panels, control room and electrical works at o.krishnapuram in trichy metro under tkc thro e tener - electrical material supply, power transformer 33/11kv, 8mva power transformer with oltc, breaker along with ct for outdoor ss 33 kv (gc) vcb (out door) 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (600-300/1-1a) with structure and complete accessories with breaker platform., 11kv (lv) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulatedwith permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (1200-600/1-1a) with structure and complete accessories with breaker platform., 11kv (feeder) vcb (out door) 12 kv, 1250a, 26.3ka per 3 sec., 3 pole gang operated soild dielectric insulated with permanent magnetic actuator operating mechanism with inbuilt vcb bushing embedded dry type epoxy resin cast ct (400-200/1-1a) with structure and complete accessories with breaker platform., potential transformer 33kv potential transformer with tc (single phase unit), 11kv potential transformer with tc (three phase unit), panels ac panel for 33kv ss, 110 v dc annunciation panel type b, 110v dc indoor c&r panel for gc breaker, 110v dc indoor c&r panel for lv breaker, 110 v dc indoor c&r panel for twin feeder, control cables, junction box and accessories 14c x 2.5 sq.mm copper cable armoured, 8c x 4 sq.mm copper cable armoured, 4c x 4 sq.mm copper cable armoured, 4c x 2.5 sq.mm copper cable armoured, 2c x 2.5 sq.mm copper cable armoured, isi mark 19 / 22 mm cable gland as directed by the field engineer., isi mark 25 mm cable gland as directed by the field engineer., isi mark cable 28 mm gland as directed by the field engineer., lugs, ferrules, sleeves, cable tie, insulation tape and other accessories for providing cable core end termination, supply of gi chequerred plate 6mm thickness, junction box supply of ct/pt junction box made out of 14swg (2mm) m.s.sheet wherever required as directed by the field engineer. the box shall be vermin proof shall have sturdy hinges, provision for mounting terminal blocks and locking arrangements including cost of all materials. 400w x 300h x 150d, supply of ac junction box of size 535x310x127mm of 18swg ms sheet including hrc fuse unit-18 nos. should be fitted with base, consumables etc. (the box shall be vermin proof, shall have sturdy hinges and locking arrangements), supply of mounting channel suitable for cbtm 5 terminal block in panel /box as required and as directed by the field engineer., supply of disconnected type terminal block suitable for ct circuits in panels/ box as required & as directed by the field engineer, supply of isi mark bakelite hrc fuse holder with fuse of 2/5/10/16 amps reputed make in panels/ boxes for ac/dc/pt circuits wherever required as directed by the field engineer. 16 amps - fuse holder with hrc fuse, 63amps - fuse holder with hrc fuse, bus & bus materials zebra acsr conductor, 2.0" / 50 mm aluminium bus bar (thickness:5 mm), 22/33 kv pt insulators, 11kv pt insulator, 11kv, 120kn disc insulators (antifog), strung bus eye bolt of 18 - 20 mm dia gi rod of required length suitable for 33kv, 22kv and 11kv strung bus including cost of gi rod and 2nos gi nuts & washer as directed by the field engineer., clamps and connectors tension fitting clamp 4 bolted for zebra, t clamp for 2" bus to single zebra, t clamp for zebra to zebra, switchend clamp for single zebra, switchend clamp for 2" busbar, reducer clamp for 2" bus to zebra, pg clamp for zebra, free end clamp for 2"busbar, corana bell for 50mm bus bar, switch end clamp for mink, seating block for 2" bus bar(for g

State Government

CTN :42777406 Due date: 16 Dec, 202516 Dec, 2025 5.34 Lacs
Tender For corrigendum : rerouting agasthyacodu feeder by using ug cable to avoid complex structure of power house 4 pole under electrical section punalur of electrical division punalur - rerouting agasthyacodu feeder by using ug cable to avoid complex structure of powerhouse 4 pole (cw-4593-202526-30) under electrical section punalur of electrical division punalur
 Loading, Please wait...

Connect us via What's Up