Tender For tender for design, manufacture, testing, supply and installation of fully automatic transformer winding resistance measurement kit , circuit breaker time interval testing kit 6 channel, contact resistance measurement kit 200a digital micro ohmmeter, electro mechanical relay testing kit & 5kv digital ir with induction compressor and others conforming to kptcl specification for rt circle, kptcl, chitradurga which is under chief engineer electy., transmission zone kptcl, tumkur on f.o.r.d at store site basis, including insurance and transportation & unloading
Tender For annual rate contract for work of supply and fixing of various electric spare parts for starter and panel ci specials sluice valve nrvs of various uwss city sardarshahar under phed div sardarshahar - 261400 supply and fixing of oil / air break dol / star delta starter made out of sheet steel powder coated enclosure with single phasing protection, on / off push buttons, etc. complete in all respect suitable for following rating motors.261420 fully automatic star/ delta starter261424 30.0 hp to 35.0 hp, 261400 supply and fixing of oil / air break dol / star delta starter made out of sheet steel powder coated enclosure with single phasing protection, on / off push buttons, etc. complete in all respect suitable for following rating motors. fully automatic star/ delta starter261423 20.0 hp to 25.0 hp, 100700 p&f 240/415 v porcelain kitkat fuse (/hbc type) conforming to is:2086,1983 0n existing board/ sheet including making connections with lugs, testing etc. as required100706 100 a ,415 v100706.2 group - 1, 080300 sf of (0-500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.080301 analog type ( 96 mm x 96 mm )080301.2 group - 1, 080400 sf of ct operated direct reading type ampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required.080410 analog type ( 96 mm x 96 mm )080411 below 500 a080411.2 group - 1, 080600 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc. as required .080600.2 group - 1, 080800 sf of 110/220 v, led (22.5 mm dia ) indicating lamp with integral circuit, terminal block, including connection etc. as required.080802 blue colour080802.2 group - 1, 081400 p & f cam operated rotary switches on existing panel with 2 way and off position081410 one pole081412 32 a081412.2 group - 1, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081513 32 amp.081513.2 group - 1, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081513 32 amp.081513.3 group - 2, 081500 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947-4-1/iec:947-4-1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.081510 3 pole power contactors with following ac 3 rating081516 70 amp081516.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081702 15 to 20 amp081702.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081703 21 to 30 amp081703.2 group - 1, 081700 p & f thermal over load relay with built in single phase protection and having at least 1no & 1nc contacts, manual /auto reset facility including making connection testing etc. as required.081704 31 to 40 amp081704.2 group - 1, 082000 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16-20 amperes including making connection, programming etc. as required082002 one day & week reserve (mechanical type )082002.2 group - 1, 090600 sitc of quick make and q
Tender For corrigendum : supply of hronas on delay timer : : - chronas on delay timer 0 30 second bch make size type blrm 220v ac , limit switch in casted housing bch make size type lla oil tight , limit switch in casted housing bch make size type ltpr oil tight , limit switch in casted housing bch make size type ll1 oil tight , pneumatic time delay relay bch make type rtpn size 220vac 0point5dash60s 2noplus2nc , 10 pins connector set harting make size 10 pins connector set , 16 pins connector set harting make size 16 pins connector set , 24 pins connector set harting make size 24 pins connector set , mushroom head actuator with 1 nc emergency stop legend size cat no jaf10000 , rotary switch 4 way 6adashs6dash61070 dashb13dash tdyr size 4 way , rotary switch 6 way s6dash61052dashb13 size 6 way , rotary switch 8 way 6adashs6dash61054dashb13 tdyr size 8 way
Tender For supply of ux. protectionrelay q-118 with jss/mil gr.electronics components timer and other requirement as per clw specn.no.clw/es/r-27, alt-z sr.no.1 of sheet-13/a firm's accepted offer make: comatreleco make off time delay relay type ct32.1/110v dc for q-118 application consisting of timing module ct32/dc110v r- 1 no., plug in relay c31w/dc110v s - 1 no., system socket s3m0 - 1no.,with base and mounting arrangement only as per clw specification no. clw/es/r-27z. svc clause applicable only
Tender For drop out delay time relay anti skid true off delay control of lhb ac coaches, supply voltage: 110-240volt ac/dc. make abb (ct-ars.21s), seimens (3rp25401aw30), schneider (re22r2kmr), l&t (23gdt0), dold (mk7873n) as per bom of rdso?s specification no rdso/pe/ spec/ ac/0184 -2015 (rev-1).