Tender For pump motor protectionrelay with phase failure, overload and dry run protection & under/over voltage protection, auxillary supply: 415 v ac. similar to minilec make model: s2cmr1. make: minilec, gic, schneider only required. [ warranty period: 12 months after the date of delivery ]
Tender For supply of e4963013 01 3element transformer protection aux. relay model: vaa31(2no contact sr) /element, with aux , 02 tcs relay(95) , vax31, (2no+ 1nc) with aux supply 24 v dc) as per ann-a, item - 02.
Tender For tender for supply of periodical maintenance and operation of electrical and mechanical installations involving operation , repairs and maintenance , attending to complaints/faults/ breakdowns and taking rectification action , ensuring serviceability/satisfactory working condition of the systems , carrying-out preventive maintenance , maintenance of records/ documents etc. under this contract on all working days including saturdays , sundays and holidays as per tender specifications , terms & conditions by providing/engaging following minimum number of man power i/c reliever. (a) highly skilled (sr. supervisor) - 1 nos. (b) highly skilled (supervisor) - 1 nos. (b) skilled data entry operator - 1 nos. (c) skilled technician - 14 nos. i/c relievers (d) unskilled helper - 14 nos. i/c relievers total minimum manpower i/c reliever- 31 nos. note- relievers shall do duty of electrician//helper as per site requirement. , carriage of diesel (4 drums 200 ltr each) from petrol pump (any petrol pump among located in kushinagar as decided by eic-aai) to the sub station (dg set room) which includes hiring of vehicle loading & unloading of empty and oil filled drums at site. note - empty drum will be provided by aai. , servicing of l&t make , model u-power omega air circuit breaker 630/800 a through l&t service engineer / l&t authorized service engineer including carrying out of following works- racking out & removal of acb from electrical panel , cleaning all parts for dust deposits foreign particles etc , degreasing the various parts of acb. cleaning all parts with cleaning agents such as crc 2-26 checking the various relay/protection settings and other setting of acb contacts , releases etc , checking the hardware for wear & tear , checking of termination & tightness , checking for all hardwares for its presence , replacement of spares / accessories for defective / worn out items (supply of spares / accessories required for healthiness of acb are in aai scope) , regreasing of the acb parts as recommended by oem , refixing the acb , testing and observance for normal operation of acb complete as required. note - service report to be submitted in l&t letterhead / l&t authorise service dealer letter head. , one time servicing , maintenance , testing , overhauling of complete out door type package/ compact sub-station of m/s c & s make through oem service er. or oem authorised dealer /service er.only as per the oem recommendation and scope of work of tsc/ scc of the contract. pss is comprising of following- ht panel - 12kv , 630 a , 21ka/3sec , 2way non extensible sf6 insulated rmu comprising of 01 nos. 630a manual load breaker switch and 01 no. 630a manual vaccum circuit breaker. transformer - 11kv/0.433kv , 400 kva oil type transformer -01 nos. lv componenet - 4 p , 630a , drawout acb - 01 no. 3p 400a mccb for capacitor panel capacitor panel - apfc 200kvar capacitor panel- 01 nos. pss is comprising all above i/c metering , relay etc complete. oem service er. has to submit the relay calibration report along with service and maintenance report of transformer , rmu , ht & lt panel and capacitor panel i/c healthiness report after service and other report if any as per oem recommendations complete. , carriying out the dehydration of transformer oil of 400 kva transformer (make - kotson) in 400 kva c &s pss at site i/c transportation of dehydration machine , di-electric strength test (bdv value) of oil before and after dehydration at site and submisstion of report as per requirement. note - the transformer having capacity of 330 ltrs of tranformer oil. , supply of new transformer oil conforming to is-335 in non-returnable barrel as per requirement. , one time servicing , maintenance , testing , overhauling of complete outdoor type package/compact sub-station of m/s sudhir power make through oem service er or oem authorised dealer /service er.only as per the oem recommendation and scope of work of
Tender For supply of spares of field switches for drills e e - shunt trip coil assembly, part no - v0021 , electrical release coil assly, part no - v0022 , aux. switch assy, part no - v0024 , soloinoid coil for closing mechanism, part no - v0025 , antipumping realy for solinoid, part no - v0026 , closing contactor for solenoid, part no - v0027 , flex connector, part no - v0028 , support insulator single hole for vcb, part no - v0031 , secondry plug and socket, part no - v0032 , fibre glass barrier set for fixed type v, part no - v0039 , drive insulator for vcb, part no - v0041 , vacuum interrupter, part no - v0048 , vacuum circuit braker assly. vcb9576, part no - vfs0062 , indicating lamp, part no - p0043 , trip neutal close switch, part no - p0045 , rectifire capacitor, part no - p0048 , earth leakage relay, part no - p0049 , over current relay single pol, part no - p0050 , resin cast core balance transformer, part no - p0051 , potential transformer 11 kv 110 v,100, part no - p0053 , resin class ct class isp10 ci10, part no - p0056 , 6.6 kv plug complete, part no - p0064 , 6.6 kv socket insulator, part no - p0065 , idmt relay, part no - p0083 , motor protectionrelay, part no - fsv00121 , ht hrc fuse for p.t., part no - fsv00110 ) /bid number : gem/2026/b/7522304 * /dated: 09-05-2026 & & / bid document 1 / 32