Get complete information related to latest Pumping Line Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pumping Line Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pumping Line Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39517746 Due date: 22 Mar, 202522 Mar, 2025 NA
Tender For corrigendum : package-a erection, commissioning & trial operation of main circulating cooling water, auxiliary cooling water including application of lining, insulation, supply & painting as and where required including handling of materials at bhel / clients stores / storage yard and transportation to site, and handing over of main circulation cooling water supply and return line from condenser to cooling tower including e&c of bf valve, arvs etc and any other equipment/structure required for the completion of the package, auxiliary cooling water supply line upto a-row of power house along and acw return line branch piping, including supply & installation of items as per boq of 2x800 mw ntpc singrauli stage iii project. package-b erection, commissioning & trial operation of low pressure piping and fire protection system piping including handling at site stores / storage yard, transporting to site, inspection, pre-assembly, erection, alignment, welding, ndt, fixing of hangers & supports, chemical cleaning / pickling, oil flushing, water flushing, hydro testing, surface finish, supply and application of wrapping and coating materials for under ground piping, supply & application of primer & finish paints including labeling & flow direction on the piping & hangers and supports, precommissioning, commissioning, assistance for trial operation of the units & handing over to customer of 2x800 mw ntpc singrauli stage iii project.

corporations/Associations/Others

CTN :39558734 Due date: 07 Apr, 202507 Apr, 2025 1.29 Crore
Tender For procurement of rubber parts - hose for radiator tt bsiv 12mtr jnurm 1616, rubber hose(thermostat to water pump) tt.bs iv ks 1616, rubber hose (ucwl to thermostat) tt.bs iv ks 1616, rubber bush - arb top link ll midi bs iv, rubber bush ll midi bs iv, rubber bush ll midi bsiv, rubber bush tt midi bs iii, hose assey filter to fip / flexible pipe - ll midi bsiv, l/l bs-4, e.g.r.pipe / sa of coolant inlet pipe seco, l/l brake pedal rubber (moulded)/ tread plate, eicher bs-4, radiator bend hose upper, tata midi rear engine bedding, tata midi front engine bedding rh, tata midi front engine bedding lh, t/t bs-3, 12 mtr jn.nurm, hose engine to radiator / inchs inch type, rubber holder with rod /rubber connector sub assbly, leyland rear engine bedding / metacone mounting, d bar bush/v bar bush/spherilastic bush taper, tata bs-3, 12 mtr jn-nurm , leveling valve assbly, t/t bs-3, 12 mtr, jn-nurm rear air bellows (380/300) 12 inch, pipe oil seal, pipe oil supply comp(hcv,mav,terra16,25), seal side, leak off pipe, hose clamp radiator tata bsii, radiator hose, hose plain, hump hose leyland 12 mtr, hose assy, cacinlet hose, a c main rubber hose 1510 tata bsii, radiator hose tc, fuel flexible pipe small leyland bsii/iii/iv, fuel flexible pipe big leyland bsii/iii/iv, pipe,filter inlet, assy return pipe, cusion rubber fr engine mtg, sa of bump stop, metacone mounting double flange, leyland bs3/bs4/eic-bs3,bs4 centre joint rubber with bearing, hose diffuser hump, cushion rubber rear engg mtg, waveller rubber pad, fuel hose - eic bs iii, hose fuel 6x40 - eic bsiii, rubber hose / pipe over flow (6x150) - eic bs iii, hose fuel 6 x 110 for - eic bs iii, hose dat, (radiator) - eic bs iv, dat hose (thermostat) - eic bs iv, hose, upper fill line - eic bs iv, assy. pipe air inlet - eic bs iv, hose, lower fill line - eic bs iv, hose tc out - eic bs iv, bellow intercooler - eic bs iv, assy coolant pipe outlet - eic bs iv, pipe bunch assy heating line (ad blue pipe) - eic bs iv, assy hose radiator lower - eic bs iv, assy coolant pipe/hose inlet - eic bs iv, hose inlet, radiator - eic bs iv, hose ,intercooler out - eic bs iv, pipe assy fill line, dearation tank - eic bs iv, rear engine mtg lower lh - eic bsiv, rear engine mtg lower rh - eic bsiv, center bearing rubber - eic bs iii, assy compressor oil inlet(e694 engine) - eic bs iv, tube - eic bsiv, assy high pressure pipe 7(e694 engine) - eic bs iii, rear engine bedding - eic bs iii, hose dearation tank - eic bs iii, radiator hose / pipe - eic bs iii, hose dereation tank - eic bs iii, pipe deaeration tank assy - eic bs iii, hose (mav cowl) - eic bs iii, hose manifold inlet (hcv) - eic bs iii, hose radiator upper (30.25/33.25) - eic bs iii, hose radiator lower (30.25/33.25) - eic bs iii, hose intercooler inlet (tipper/6x2) - eic bs iii, hose outlet precleaner (tipper) - eic bs iii, water outer hose (e683tc/tci) - eic bs iii, hose intercooler outlet (hcv) - eic bs iii, front brake hose assy - eic bs iv, crimped hose assy 570l (ac hose) - eic bs iii, bump stopper, front axle (hcv) - eic bs iii / iv, compressor hose 350mm- eic bs iv, cushion centre (hcv) - eic bs iii, bracke front engine mouting rh (hcv) - eic bs iii, front engine bedding / cushion rubberrear engine mtg (hcv) - eic bs iii, voccum indicator hose - ll bs iii / iv, centre bearing rubber - t/t bsiii l/l bsiii / iv eic bsiii / iv, centre bearing rubber 12 mtr - ll bs iii / iv / vi, s cam bush - ll bs iii / iv / vi, bush for injector bs iii, a/c hose assy 30cm / leyland midi a c hose - ll bs iii / iv / vi, frt & rear engg. mounting pad - ll bs iii / iv / vi-f2604200, pipe - radiator outlet - ll bs iii / iv, pipe - radiator outlet to water pump inlet - ll bs iii, cac inlet hose - ll bs iv / vi, straight hose - for radiator piping - ll bs iii / iv, cac outlet hose - ll bs iii / iv, radiator reducer l hose bsiv, radiator reducer l hose - ll bs iv, s cam o ring - ll bs iii / iv / vi, engine mounting pad / bedding front - ll bs iii / iv / vi, front e

Central Government/Public Sector

CTN :39650393 Due date: 28 Mar, 202528 Mar, 2025 NA
Tender For construction of 03 nos of borewell with piping for drinking water at barakar river bed for supply to sgw.

Central Government/Public Sector

CTN :39145973 Due date: 13 Mar, 202513 Mar, 2025 NA
Tender For bid to ras custom bid for services - comprehensive annual maintenance contract of cs12 eakon cold store located at doddanekundi plant acd for a period of 3 years -summary: comprehensive annual maintenance contract includes maintenance, repair/replacement of all the components of the cold stores as follows: a) compressor, condenser unit, evaporator unit, suitable refrigerant, power supply system, control system, all safety features, operator panel, different type of sensors, interconnecting piping including drainage water pipes, cold room panels, coil and drain heaters, doors, lighting, temperature recording panels, and all other electrical, mechanical as well as electronics components of the systems & eurotherm electronic recorder.b) detailed scope of work:1 vendor should take over the cold stores for camc, in as-is-conditions., 2) preventive maintenance (pm) of the units to be carried out every month in consultation with user / maintenance dept, and detailed pm schedule to be drawn up and a copy of the pm carried out (service report) should be forwarded to purchase department duly endorsed by maintenance dept. for the reference and records. this pm should be carried out apart from periodical servicing and attending the breakdown calls. 3) servicing of the units should be carried out once in every three months, within two weeks of commencement of the quarter. this should be carried out preferably on sundays/ holidays. this servicing involves cleaning of condensers, cooling coils, filters (if any) leakage testing & rectification; and any/all other works required to ensure proper functioning of the units. a copy of the service carried out (service report) should be forwarded to purchase dept. duly endorsed by user/ maintenance dept for the reference and records. 4) the firm should monitor the temperature/ attend breakdown / preventive maintenance or any other request from user/ maintenance /quality dept. & monitor the functioning of all the cold stores. the firm should monitor and record the cold store chamber temperature every hour during shift hours and should take signature on recorded values by user, quality dept /maintenance dept. daily. the camc vendor s scope of work will be active for three shifts per day/round the clock, including sundays & holidays, i.e. all days throughout the camc period. 5) the firm should inform all the three departments user/qa/maint. in the event of malfunctioning of the equipment is noticed. they also should ensure safety of the materials stored in the event of failure of the cold stores. 6) the firm should report any abnormality, breakdown, or any bypass made immediately to all the three dept viz user, maintenance and quality dept. the equipment uptime should be greater than 95% without any interruption. 7) the firm should inform to the maintenance department in the case power failure, so that maintenance dept. can arrange for switching on the dg supply. 8) the firm should able to read the temperature in the electronic temperature recorder. 9) the firm should attend any number of breakdown complaints as and when reported by user/ maintenance dept/ quality dept during the contract period. the breakdown complaints should be attended within 8 hrs from the receipt of oral or written complaints and the system should be rectified within a day, except for the major breakdowns. 10) the firm should bring all the tools and tackles necessary including consumables for the repair / servicing. 11) the firm should hand over the cold stores in good working condition after the completion of camc, failing which necessary remedial actions will be taken to recover loses to acd-hal by deducting equivalent amount from the due amount. c) monthly checks: checking and servicing of cold stores.- (a) compressors- condensing units, solenoid valves and all gauges, drier, globe valves and all gauges, hp/lp switches, oil pressure switches ., expansion valve and mixture., refrigerant level and top-up if requir

State Government

CTN :39036077 Due date: 19 Mar, 202519 Mar, 2025 69.59 Crore
Tender For corrigendum : supply, installation, testing and commissioning of chilled water piping network and building valve stations to provide district cooling services for upcoming buildings in sez and dta area of gift city

Central Government And Public Sector

CTN :39626347 Due date: 22 Mar, 202522 Mar, 2025 18.58 Lacs
Tender For fabrication, hydro testing, radiography testing, erection, hook up and supporting of process and utility metallic piping at heavy water board facilities, vadodara.

Central Government/Public Sector

CTN :38841029 Due date: 17 Mar, 202517 Mar, 2025 NA
Tender For corrigendum : supply, transportation, installation and commissioning of additionalmake up water piping package (0-20 km) at ntpc khargone

Central Government/Public Sector

CTN :39606690 Due date: 28 Mar, 202528 Mar, 2025 19.08 Lacs
Tender For providing of custom bid for services - hiring of services for application of geosynthetic cementitious composite mat gccm under the firewater network piping between fire water pump house and fire water storage tanks t4701 ab

Central Government / Public Sector

CTN :39607050 Due date: 21 Mar, 202521 Mar, 2025 3.47 Crore
Tender For providing of custom bid for services - agency for replacement of process & utility piping, fire water lines/sprinklers line replacement etc. asper inspection rec-ommendations in om&s, lpg, bfu, ttl, twl, offsites and water block

Central Government / Public Sector

CTN :39614711 Due date: 14 Mar, 202514 Mar, 2025 NA
Tender For modification in fire water network at wrpl vadinar - modification of fire-fighting network, supply of spiral wound metallic gaskets 28" swmg ansi 150#, supply of steel fasteners - fasteners for flanges ( 0.75" dia. x 6.75" length ) - extended stud length for flanges, 30" x 28" 150# conc. reducer, 30" x 24" 150# conc. reducer, dismantling of piping (aboveground) and equipment dismantling of existing over ground piping works of all types and sizes by opening flange joints, installation of ball/gate valves mov/hov 28", 150#/300#, f/f: taking delivery of valves of all types and pressure rating from the designate store, installation of 24" valves, above ground internal epoxy coated pipe