Get complete information related to latest Pyrometer Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pyrometer Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pyrometer Scrap Tenders.
Tender For corrigendum : supply of glucostrips with meter , rapid pregnancy test kit dipsticks , rapid test kit malaria , n10 hydrochloric acid , urine strips for protein and sugar , disposable syringe with needle s 2 ml , disposable syringe with needle s 5ml , disposable syringe with needle s 10ml , disposable gloves , alcohol swab , whole blood finger prick hiv rapid test , sti screening test , disposable lancet , wooden spatula , red disposable bags , black disposable bags , blue disposable bags , yellow disposable bags , tourniquet , slide drying racks , spirit lamp , test tube holding clamp , test tube rack , lab autoclave , needle destroyer , cusco speculum , lamp with stand , sponge holding forcep , rapid test kit for dengue igg igm , hemoglobin test strips (q2)
Tender For lab kits/reagents/consumable item for blood bank-, anti a blood grouping (anti a monoclonal serum) -10 ml, , anti a lectin-1x10 ml, , anti ab antisera-1x10 ml, , anti b blood grouping (anti b monoclonal serum) -10 ml, , anti d (rn) blood grouping serum -10 ml, , anti h lectin-1x10 ml, , adhesive plaster 4 inch wide, , band aid adhesive strip, , blood weighing machine (0-1 kg), , bovine albumin -1x10 ml, , coomb's antisera-1x10 ml, , double blood bag, , lancet, , multi channel tips (0.5-10 ul-compatible) -1x1000, , multi channel tips (10-100 ul-compatible) -1x1000, , multi channel tips (30-300 ul-compatible) -1x1000, , multi channel tips (50-50 ul- compatible) -1x1000, , pediatric blood bag, , rpr/vdrl test kit, , rubber ball for donor use, , signal cpda 350 ml blood bag blood collection bag made up of dehp(di-2-ethyihexylphthalate) plasticized pvc collapsible non vented sterile containers with collecting tube for completely closed system to avoid the chances of contaminating.single blood bag capacity -350ml. needle-16 gauge ultra thin walled and straight. blood bag tube should have multiple printed id/segment numbers. (external port should be tamper proof and, , shouldn't be recapped.anticoagulant_cpda-1(49ml.) it should be clear & colour less.), , tissue paper roll, , tornic belt, , triple blood bag 450 ml with sagm mother bag of triple blood bag should have 450ml capacity with 63ml cpd solution and is connected to one satellite transfer bag of 400ml capacity and one satellite transfer bag of 400ml with 100ml sagm. mother bag should be 35mm to 50mm thickness to prevent breakage during centrifugation and the inner diameter of the tube should be standard measurement. needle should be 16g with triple. bevel design to reduce penetration force and enable painless vain puncture. blood bags and its packing should be properly labeled with batch no. mfg date and date of expiry. product labels should be bar-coded as per rule. complies to iso 3826 and quality of components stored as per indian drugs and cosmetics act. for the manufacturers have to produce documentary evidence from the laboratories approved by government of india., , weighing machine (donor), , disposable blue tips for microplpettes (2-200ui) -1x1000, , disposable yello tips for microplpettes (200-10010ui)- 1x1000, , finn pipette variable volume (100-1000 ul), , finn pipette variable volume (10-100 ul), , hbsag elisa test kit 4th gen. hbsag elisa test kits (specification-sensitivity & specificity should be100% must be able to detect 0.5 or less ng/ml. 4th generation hbsag)- test kits must have a long shelf life. detects all known 11 sub-types of hbv and also mutant strains can be used on any manual/semi-automatic system of elisa. 1x96 test., , 1. the kit to be procured should have approval of the statutory authority in its country of origin., , 2. in case of imported kits it should have been registered and licensed in india by dcg (i)., , 3. in case of indigenous manufacturers they shall have license issued by the competent authority defined under drugs and cosmetics act, 1940, after appropriate evaluation by the centers approved by dcg (i)., , hbsag rapid test kit (rapid test) 4th gen. specification-sensitivity & specificity should be100% must be able to detect 0.1 or less iu/ml. it should detects major vaccine escape mutants14t126n,t126s, q129r, q129hq129l, m133h, m133l,k141 e,p142s,t143k,d144a, g145r,t123a, p120q it should have single step procedure, subtype serotype-a/h,a/e,a/f,d/g,d/f,d/g specimen: serum/plasma, finger stick whole blood and vein puncture whole blood, , hcv elisa test kit, 4th generation, , 1. microplate elisa coated with recombinant/synthetic peptide antigens for core, ns3, ns4 and ns5 and antibody to hcv core antigen., , 2. adequate documents detailing the principle, components, bio-safety, methodologies, validity criteria, interpretation of results, performance characteristics, storage conditions, limitation of assays, manufacturing &a
Tender For purchase of lab instruments for physics core laboratory for the year 2025 under idukki package - digital function generator {0.2 hz to 2 mhz, sine, square, triangular wave, signal amplitude of 20vp-p output }, cro digital- 100 mhz dual channel, arduino set, daniel cell, equivalent, electronic digital vernier calipers, inch and millimeter conversion,lcd screen displays 0-6" caliper measuring tool, automatic shutdown, laboratory thermometer (lc:0.5 degree celsius , should measure upto 150 degree celsius), double slit with various widths marked on, prism equilateral- flint glass, with one face grounded (2"), prism equilateral- crown glass, with one face grounded (2"), voltage source (variable) [0-30 v, 2 outputs, digital display], digital multimeter with voltage ( ac- at least 200 mv to 500 v, dc), current ( ac and dc from ma range) , resistance, frequency, transistor gain (hfe) measurements, laser source- diode 650 nm, 5mw fixed on stand with power supply, solar cell characteristic apparatus, single slit, with various slits marked on the instrument, diffraction grating with 100 lpi/200 lpi/ 500 lpi or their combination with marking on the instrument (different lpi preferred), micrometer screw gauge 0-25 mm, 0.01 mm lc, screw gauge digital micrometer 0-25 mm, 0.01 mm lc, stainless steel digital vernier calipers, 6 inch, stop watch- electronic digital, spectrometer arrangement, lc 1 , travelling microscope, both vertical and horizontal movement lc 0.01 mm, quartz prism- equilateral, mercury lamp with pins ( not screw type), common weighing balance- digital , to weigh upto 10 kg, lc 1gm, digital light intensity meter (range 0 to 200000), katers pendulum, with holder, narrow angle (small angled prism angular measurement 5 x 87.5 x 87.5 ie 5 degree size 32 x32 mm) crown glass, travelling microscope, (bridge) horizontal movement lc 0.01 mm , for newtons ring and airwedge experiments, digital ic tester, analog stop clock (lc:0.5s), diffraction grating with 15000 lpi, digital oscilloscope dual channel input signal generator 100 mhz 1gsa/s sampling rate 7" tft display 240 kb storage, oscilloscope - 2.8" tft handheld digital oscilloscope kit portable automotive oscilloscope, 2.5ms/s high sampling rate, 200khz bandwidth, trigger function auto/nomal/single, helium neon laser 2mw, with power supply, half wave, full wave & bridge rectifier trainer kit, op amp trainer kit -to study op-amp inverting, non-inverting amplifier circuit, to study op-amp summer & subtractor, to study op-amp comparator circuit, to study op-amp voltage follower current follower, to study op-amp differentiator and integrator circuit.to study op-amp null detector, offset current & voltage circuit.to study op-amp clipping amplifier.to study op-amp sample & hold circuit.to study op-amp schimitt trigger circuit., hall effect apparatus complete set, 4 probe experiment apparatus for resistivity and bandgap of semiconductor, bh curve apparatus to study the retenvitya nd coercivity of a ferromagnetic material, apparatus to measureelectrical conductivity of metals and estimation of fermi energy., digital lab thermometer. resolution : 0.1 degree celsius, at least measure upto 200 degree celsius, horse shoe magnet for sonometer experiment (approx 6 inch), stainless steel ruler to measure upto 0.5 mm, digital lcr meter (range: 0.1 h to 20h, 0.1pf to 2000 f, 0.1ohm to 20mohm), special wire stripper for electrician decrustation pliers multi-functional wire stripper and cutter, wire cutter tool, wire cutter stripper, wire cutter plier, 25 pieces spanner set 6 mm to 32 mm