Tender For corrigendum : supply of tank primary radar gauges at vijaywada tl - sup of primary radar ag tanks fr crvt , erec instal of primary radar ag tanks fr , commisioning testing of ag tank radar , supply of water ag tanks radar , insta erection water ag tank radar , comistng testing of water ag tank rada , tankside indicator w lcd display , insta erection tsi , comistng testing tsi , sup of ag tank pt with 2 valves , insta erection pt with 2 valves , comistng testing of pt , sup of mst cum wls ag tanks , insta erection mst cum wls ag tanks , comistng testing mst cum wls ag tanks , supply of radar level gauge for ug tanks , install erection of ug atg probe , commisioning testing of ug atg probe , sup of sst cum wls ug tanks , insta erection sst cum wls ug tanks , comistng testing mst cum wls ug tanks , sup of density probe for ug tanks , insta erection density probe for ug tank , comistng testing density probe for ug , sup of ciu with redundancy , insta erection ciu with redundancy , comistng testing ciu with redundancy , sup client pc with tfms s w , insta erection computer interface unt , comistng testing computer interface un , manditory spares as per list , camc for 8 years , oem service engineer 8 hrs , sup of density probe for ag tanks , comistng testing density probe for ag
Tender For supply of supply, installation, testing and commissioning of primary radar gauge,sitc of secondary radar gauge,sitc of multistage temperature sensor,sitc of pressure transmitter,sitc of vft level switch,sitc of tank side indicator,sitc of push button,sitc of emergency push button,camc of equipments,sitc of open path type hcd,sitc of point type hcd,oem engineer visit
Tender For corrigendum : supply of installation of damaged spare parts of plc and scada system - control transformer 1kva , motor protection cuircuit breaker, range- 51 -70a , breaker handle with knob, siemens 3vt series , panel door lock for power pack , ethrnet switch 5-port unmanaged, ports- 5 unmanged type aux. supply- 24vdc , smps din rail mounted 24v dc 10a, output- 24v dc, 10a din rail mounted type , star delta timer, 0 -60 sec , panel fan, 220v ac, size 6 inch , mcb 2.0 amp. single pole , mcb 4 a single pole , single pole mcb 6 amp , mcb 4 a double pole , dc mcb double pole 220 v dc 06 amp , tripple pole mcb 4a, c04 , mcb tripple pole, c curve, 6amp , relay 8-pin with base, 8-pin 24v dc with base , space heater, rating-500w 230v ac , pressure gauge, analog type, range- 0-500kgf per sq. cm , tank oil gauge, tank mounted direct measuring , directional solenoid valve, operating pressure- 315 kgf per sq. cm coil voltage-24v dc , gate position sensor for radial gate, e1-type range 0- 360 degree, analog output 4 - 20 ma , indication light - blue, indication lamp 22.5 mm 220v ac blue , differential pressure transmitter, two wire 4 -20 ma dc output with hart , level transmitter accuracy 5-10 mm , gate position indicator 5 digit 0.56 inch display 21 , voltmeter 0- 500v - analog , push button red with nc add on , ammeter, 0 -250a analog , indication light - red, indication lamp 22.5mm 220vac red , indication light - yellow, indication lamp 22.5mm 220v ac yellow , indication light - green, indication lamp 22.5mm 220v ac green , jumbo display size 6.5 inch usb ports 2.0 x 1, 3.0 x 1 , push button yellow with no add on, size 22.5 mm , push button blue with no add on, size 22.5 mm , push button green with no add on, size 22.5 mm , push button black with no add on, size 22.5 mm , emergency push button, size 22.5 mm , phase preventer relay system ac mode auto , utp cable cat-5e , cable 1.5 sqmm 4c flexible 100m bundle , 1024 tags and ddls of scada system , control terminal block, 2.5sq.mm , service engineer charges , traveling charges , freight charges
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For supply, erection, testing & commissioning of 500 kva outdoor, plinth mounted, oil immersed, non-sealed type (transformer tank body and cover are bolted) distribution transformer, 500 kva rating, 11kv/415v, 3-phase, 50 hz, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled, off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, with all standard fittings as per clause 20.1 of is 1180 (part 1) and oil temperature indicator & winding temperature indicators, drain-cum- sampling valve (3/4? nominal size thread,is:554) of steel with plug, energy efficiency level- 3 & above, conforming to is 1180 (part 1): 2014 with amendment nos. 1,2,3 & 4. following has to be submitted along with supply of material:- (i) type test report as per is: 1180 (part 1) of transformer having same rating, make (& model if any) and design from nabl accredited lab. (ii) routine test certificates as per is: 1180 (part 1). (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is:1180(part 1) accepted make : andrew yule/aeg/crompton greaves/kirloskar electric co./abb /siemens/ schneider electric or equivalent.