Tender For installation of various instruments and monitoring system at vadi irrigation scheme - supplying, installing, testing, and commissioning of a v-notch weir mechanical flow measuring device) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge.with different sizes mentioned below: (1) 90° vnotch- 20 x 40 secticin 15 lit/sec, providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge., providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc (c) concrete grade 1:2:4 and msa-40mm(graded))
Tender For installation of various instruments and monitoring system at thebi irrigation scheme - supplying, installing, testing, and commissioning of a v-notch weir (mechanical flow measuring device) for measuring low flow seepage in dams. the device shall have a notch angle of 22.5°, 45°, 60°, or 90° depending on discharge range, a stainless steel ss-304 / ss-316 plate with thickness of 3–5 mm, and be suitable for measurement ranges of approximately 0–50 l/s depending on notch angle. the weir shall have ±1% full-scale reading accuracy, operate under 5–100% humidity, temperature −20°c to +60°c, and provide corrosion protection through anti-corrosion finish. complete in all respects as directed by the engineer-in-charge.with different sizes mentioned below: (1) 90° vnotch- 20 x 40 secticin 15 lit/sec, providing, installing and commissioning permanent ground control point (gcp) settlemnt marker comprising ms base plate (250×250×5 mm conforming to is 2062), gi riser pipe 25 mm dia (medium class as per is 1239), sand filling (clean river sand, loose), optional pvc/gi outer casing (min 100 mm dia), precast concrete cover (m20, 500×500×50 mm with central hole), ms/gi reference cap, and painting in black & white checkerboard pattern using weather-resistant enamel paint, complete with excavation, installation, alignment, and all materials, labour, tools, and accessories, suitable for survey works using total station / drone survey, complete as per specifications and direction of engineer-in-charge., providing & laying in position 'nominal mix' cement concrete using cement sand and crushed aggregate by machine mix incl. necessary formworks ,centering ,scaffolding compaction by mechanical vibrator curing as directed with all lead & lift etc (c) concrete grade 1:2:4 and msa-40mm(graded))
Tender For maintenance of electrical installation & fans in nscs at sardar patel bhawan, new delhi. (sh : providing wireless busbar temperature monitoring system for lt panels at sub station.)
Tender For auction sale of depot miscellaneousllaneous scrap - dms-scrap-ghz, lot no-342605005, scrap electrical & signaling miscellaneous item like geyser body,stabilizer,cooler body, charger,fuse monitoring system, axle counter, room heater, changer, megger machine, tumble switch, halogen filament, tx-rx coil, mini pantry lhb ac, berth light fitting, ammeter, control transformer, pump controller, emergency light, sphygnomanometer, stethoscope, temperature gun, suction machine, cardiac monitor, deep fridger, nebulizer machine, multimeter projector, vhf charger, insulation tester, iron battery container, tube light, photo state machine, panel body, light cover, led bulb, rru, scroll compressor with or without oil, led signal all type, tube light cover, halogen bulb, fan rod, fan blade, electric energy meter, sound box, tricolor torch, choke, current regulator, multipurpose dry cell battery-1.5v (type r 20), water cooler, refrigerator body, water purifier, elb gear box, starter, earthing device, street light, phase selector, hs meter, flood light fitting, mcb switch, holder off size, fan condenser off size, tf charger, speedometer, transformer body, ac operating panel body, cooler stand, transmitter receiver, tlbi, x-ray machine stand, speaker, oxygen cylinder with flow meter (ss), platform display board, display unit, gate hooter, telephone card, battery charger and other similar type items with or without nf attachment broken, damaged, rusted etc. location-stack a-south side of office garden near over head electric bridge. stack b- south side of office garden about 50 mtr near both side of pakka road. stack c-about 15 mtrs. west of rb section t-point. stack d- east side of ledger section about 40 mtr near kachcha road. stack e- inside old scrap office.