Get complete information related to latest Rail Joints Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rail Joints Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rail Joints Tenders.
Tender For tender for supply of hexagon head screw , shaft seal cover , gasket , benzing ring , unloading cylinder with single pipe connection , unloading cylinder for single pipe connection 94point4mm , unloading cylinder for single pipe connection 112point4 , rocker for unloading mechanism , bearing cup , spring , cup washer , split pin , piston ring , oil scrapper ring , spring for safety head , gasket , coils for contactor , toggle switch , door limit switch , power contactor 12a , winding protection relay , timer , ammeter selector switch , red led lamp , fuse 2a , fuse 32a , fuse 6a , thermostat for cool room , thermostat for cold room , propeller fan for cold room cooler , oil separator , terminal stud assembly for motor , discharge valve retpoint ring plate , gear shaft for oil pump , neoprene o ring , crank case heater element , dispoint pressure gauges for r 22 , oil pressure switch , low pressure switch , high pressure switch , gasket set for condensers , zinc plug , safety valve for condenser , gasket set for condenser , pressure gauges water , temppointgauges room temp , over load relay , ring end spanner set , pulley puller 12 , screw driver , filter , thermostatic expansion valve , high pressure switch cutout , oil pressure switch cutout , v belts to interconnect compressor and motor pulley , thermostatic expansion valve complete on plant , lpointppointcut out , forced air cooling unit fintex eqvt make for cold room , shock mounts for compressor , dial type thermometers , gasket 0point3mm , split pin , coil defrost heater brass tublar , back pressure valve , connecting rod bush , bearing bushing 0point25mm , sdnr valve 65 mm , v belt b70 , charging line , motor protection relay , adjustable spanner 8 inch , 8 amp hrc fuse , liquid line filter drier , voltmeter 0 500 v , pipe wrench
Tender For manufacture and supply of glued insulated railjoints 6.5 m long g3(l) type for 60kg rai ls with all fittings as per rdso drg. no. t-2572 and specification as per manual of glued joint re-print 2022 with acs 8 and with latest alteration as amended up to the date of tender notice. [ warranty p eriod: 30 months after the date of delivery ]
Tender For annual preventive / breakdown maintenance of equipments at 220/132/33kv substations under 220kv oandm division rishikesh - 220 kv switchyardtightening of 220 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 160 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 220 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work, overhauling of mechanism of 220 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 220 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 220 kv take-off assembly/ moving head assembly/rotary head devive etc. (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer, topping up of sf-6 gas in 220 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 220 kv switchyard., 132 kv switchyardtightening of 132 kv bay equipments (cb, line isolator, transfer isolator, ct, cvt and la including all connectors of droppers/runner/jumpers), cleaning of 132 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles and assistance in testing work., overhauling of mechanism 132 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete., replacement of conductor jumpers/runner/dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 132 kv terminal connector/clamp/jaw/blade etc. and tightening of related equipment (including replacement of minor conductor segment/patch), replacement of 132 kv take-off assembly/ moving head assembly/rotary head devive etc (including proper alignment) complete, unforseen work/maintenance of equipments/panels etc including tracing of fault &remidial action as per direction of site engineer., topping up of sf-6 gas in 132 kv circuit breaker/ oil in ct & cvt under breakdown/preventive maintenance (including shifting of gas cylinder/oil drums), repairing of hpsv lamp fittings/replacement of led fittings at 132 kv switchyard., 33kv switchyard:tightening of 33 kv bay equipments (cb, line isolator, ct including all connectors of droppers/runner/jumpers), cleaning of 40 mva transformer by cleaning of whole body, accessories alongwith tightening of bushing connectors, earthing, proper cleaning of cooling system, replacement of silica gel etc.complete, cleaning of 33 kv circuit breaker by cleaning of whole body including marshalling box alongwith tightening of connectors, earthing, proper cleaning of poles, assistance in testing work., overhauling of mechanism 33 kv isolator with cubicle including cleaning, lubrication and proper alignment., cleaning of equipments porcelain/ polycon (i.e.cb/ct/cvt/la/isolator/bpi) with clean cotton cloth complete, replacement of conductor jumpers/ runner/ dropper etc. including connectors/clamps, cutting /drilling of holes in clamps, replacement of 33 kv terminal connector/clamp/jaw/blade etc. and tighgtening of related equipment (including replacement of minor con