Tender For supply of electrical goods general items c c - kec , plastic cooling fan for motor 15 hp make a b b gec ngf kec , plastic cooling fan for motor 20 hp make a b b gec ngf kec , plastic cooling fan for moter 25 hp make a b b gec ngf kec , plastic cooling fan for moter 30hp make a b b gec ngf kec , crc 26 , baklite rod 2 inch dia x 1 inch mtr , hylum pipe 12mm id x 1 mtr , 16mm id x 1 mtr , 30mm id x 1 mtr , electrial tools tackless insulating cutting plier 8 inch taparia make , electrial tools tackless insulating megar 1000 v , multimeter p 3 sanawa make , nose plier 6 inch taparia make , screw driver taparia make 6 inch , screw driver taparia make 8 inch , screw driver taparia make 10 inch , phase taster 6 inch phillps make , wheel bracket for overhead cane unloader cabling , metalic carbon bush dubble tail 22 x 32 x 40 mm , metalic carbon bush dubble tail 10 x 38 x 50 mm , metalic carbon bush dubble tail 16 x 32 x 40 mm , metalic carbon bush dubble tail 10 x 15 x 20 mm , metalic carbon bush dubble tail 10 x 20 x 35 mm , metalic carbon bush single tail 10 x 18 x 20 mm , metalic carbon bush dubble tail 10 x 16 x 20 mm , metalic carbon bush without tail 10 x 15 x 20 mm , non metalic carbon bush without tail with centre groove 18 x 18 x 90 mm , non metalic carbon bush with dubble tail 16 x 30 x 38 mm , brass carbon bush holder for unloder , slipring id 50mm od 105mm length 87mm , slipring for 80 hp 970 rpm spray motor id 40mm od 122 mm length 120 , brass holder for 250 hp 585 rpm for slipring motor , insulating materials golden insiulating varnish almoluft la dr beck make , insulating materials golden insiulating bechtol varnish , insulating materials thinner for above , millinex paper 7 mile , millinex paper 10 mile , soldering strip 60 pratisat , no volt coil 220 volt bata 415 v , copper lead with fibre cover flexible wire 10 amp , copper lead with fibre cover flexible wire 15 amp , copper lead with fibre cover flexible wire 20 amp , copper lead with fibre cover flexible wire100 amp , cotton tape 3 bata 4 inch , pvc tape 3 bata 4 inch steel grip , glass fibre tape 3 bata 4 inch , copper cable lugs16 sq mm , copper cable lugs 25 sq mm , copper cable lugs 35 sq mm , copper cable lugs 50 sq mm , b c h make spares timer 2 nc 2 nc kartpn time relay range 0 60 sec 110v single way , b c h make spares off bata on swich suitable for push swich heavy duty 2nc2nc dubble plate 220 v , limit switch lv 1 , semiconductor silicon fuse link n3 50 , copper wire pvc single core 3 bata20 , copper wire pvc single core 3 bata22 , copper wire pvc single core 7 bata18 , copper wire pvc single core 7 bata22 , p v c copper wire 2 core 3 bata22 , p v c all wire single core 2 5 mm , p v c all0 wire 2 core 4 sq mm , p v c all0 wire 2 core 6 sq mm , p v c all0 wire 2 core 10 sq mm , p v c all0 wire 2 core 2 5 sq mm , workshop flaxible p v c copper wire 2 core 40 bata76 each , workshop flaxible p v c copper wire 3 core 40 bata76each , twin twisted copper wire 40 bata76 each , bare s s wire 4 swg , bare cooper wire 4 swg , solonoid valve part no 766 240 volt type 3 t 6 1 4 e c make , magnatic coil assembly for solonide valve part no 266 240 volt 326 l 4 ec make , industrial pressure switch indofas make oil pressure setting range 0 5 to 4 kgs , push button station complete on off , power capacitor complete 25 kvar bank , p v c allu wire 10mm 2 core , p v c copper wire single core 7 bata16 s w g , bare copper wire 3 s w g , hylum pipe 1inch , glass tape 1inch , cotton tape 1inch , glass sleeve 4mm sq , glass sleeve 6mm sq , glass sleeve 10mm sq , no volt coil 3 ta 24 220 volt , solonoide coil square 220 volt , mcb box for 25 amp mcb 6 way , timer 101 xc mode tmr 20c voltage 220v contact 5a 220v ac //bid details 2 / 86 28v dc resistence load , exhaust fan 18inch for power house , pvc insulation tape pack of 30 anchor by panasonic size 1 80cm x 6mtr , push button element 1 no , push button element 1 nc , push button element 1no 1nc , push button mashroom type green
Tender For supply of modernization of distribution infra 2x400 kva substation companybagh b b -dismantling and refurbishing of electrical distribution system , itc of existing load bank with static meter , itc of existing load bank , trimming and pruning of four trees , transportation of one dismantled lt panel darbhanga to mzp , removing of old faulty outlived mv panel , provision of structural iron channels mounting framework for the lt panel , re-furbishment of existing mv panel , brickwork for minor structural alterations near the lt panel support base , straight through joint 185 , straight through joint 50 , removing and relaying of existing cement interlocking bricks , laying of 1.1 kv grade of 35 sqmm to 185 sqmm direct in ground , dressing of cables , finishing of the lt bus bar box , 20w surface-mounted led tube light , a. horizontal type tpn db 8 way with double door , b. horizontal type tpn db 8 way single door , a. vertical type, 415 v, tpn db 8 way double door , dressing of dbs , a. single pole mcb 6 to 32 a , b. four pole isolator 63 a , c. four pole isolator 40 a , d. double pole isolator 40 a , e. tp mcb 63 a , f. 125 a tp mccb 16 ka , 3 pole mccb of 250a, 25 ka , itc of existing lt bus bar box , sitc wall mounted heavy-duty air circulators fans of 600mm metal blades , supplying and fixing of 5mm thick m.s.chequered plates , fixing of ms stand of pac outdoor unit , providing double coat spray painting , sign writting numbering on all panel proper marking of its connectivity , a. wiring for light point group-a , a. copper conductor, single core cable 2 x 1.5 sq. mm , a. medium class pvc conduit 20 mm , shifting re- installation of submersible pump staters , making opening of wall to suit the size of 380 mm sweep exhaust fan , supplying fixing of exhaust fan of 380 mm sweep heavy duty , a. blanking plate , b. 5 pin 15 a socket , c. 15 16 a piano type switch , d. 5 6 a piano type switch , e. 3 pin 5 6 a socket outlet , f. 3 pin 15 a top , g. wall fan , h. down rod for ceiling fan installation 3 ft length hook , a. 100 watt flood light , b. 24 w led rimless surface panel light , sitc of 100 a 3 phase neutral copper bus bar in sheet steel enclosure , dressing of existing distribution system of type ii staff qtr , itc of 100 a 3 phase neutral bus bar with 100 a mccb in sheet steel enclosure , supplying fixing of double pole spn mcb 32 a in the sheet steel enclosure , s l 2 1.5 sqmm copper conductor , removing the faulty lt cable of size 3.5 core 240 sq.mm , ms clamp on four pole structure for fixing the ht cable , extracting of spare main ht cable 11 kv 95 sq mm size from the soil , extracting of faulty spare ht cable 95 sq mm from the duct manual labour , fastners nut bolt, al lugs, socket, cu lugs socket, washers, screw, pvc clips , acrylic sheet of 2 mm thickness , hrc fuse of 200 a //bid details 2 / 49
Tender For supply ere commi of various electromechanical equipment like 5 no 5 cs vt pump electric motors starter panel and other allied material for flood protection works from the field area of village dang khurd outfall at rd 65000r of nigana feeder - supply, erection & commissioning of 5 c/s axial/mix flow water lubricated vertical flood pumps of 5 cs. discharge at 1440 rpm at static head of approx 6.0 mtr. having adjustable height, including ms bend including flange welding, ss/ht nut & bolts etc complete in all respect as per site requirement with epoxy coating & as per approved specifications of the department, supply, erection & commissioning of solid shaft motor of capacity 30 hp, 1440 rpm, 3 phase, 380 volt+- 10%, with eficiency class ie2 (with 35 mtr compatible 3 phase submersible cu cable from motor to panel/starter) suitable for fitment with 5 cs. v.t axial/mix flow pump type vertical flange mounted as per approved specifications of the department., supply, erection & commissioning of fully automatic star delta starter of cap. 150 amp including all accessories as one incomer of mccb (150amp) with 1 no mcb for lighting load, contactor rating 120 amp, 90 amp, 70 amp with control transformer for control supply, outgoing indicator, having mpr & all types of protections i.e.uv/ov/ over current, phase imbalance/phase reversal protection, locked rotor, dry run etc, digital meters, push buttons, bus bars, capacitor bank, seperate relay for single phase protection etc. complete in all respect suitable for open fields operation of 1 no. motor of capacity of 30 hp with a stand of ms channel with canopy having suitable operating height above the kachha open fields as per approved specifications of the department. (suitable for voltage range 380 +- 10%,) panel should be outdoor type., supply, erection & commissioning of m.s delivery pipe 10" dia. made of ms plate both end flanged (equal to or less than 6 mtr length of pipe) as per approved specification & make. (including ss/ht nut & bolt, rubber packing & other fitment accessory required), supply, erection and commissioning of ms girder parallel flange section ismb 150 with primer and bituminous based paint inside & outside of length 4mtr (approx wt 60 kg per pc) as per approved make & conforming to is808:2021.
Tender For supply erec comm of various electromechanical equipment like 3 no 5 cs vt pump electric motors starter panel and other allied material for flood protection works from the field area of village ghuskani outfall at rd8350 l of nigana feeder - supply, erection & commissioning of 5 c/s axial/mix flow water lubricated vertical flood pumps of 5 cs. discharge at 1440 rpm at static head of approx 6.0 mtr. having adjustable height, including ms bend including flange welding, ss/ht nut & bolts etc complete in all respect as per site requirement with epoxy coating & as per approved specifications of the department, supply, erection & commissioning of solid shaft motor of capacity 30 hp, 1440 rpm, 3 phase, 380 volt+- 10%, with eficiency class ie2 (with 35 mtr compatible 3 phase submersible cu cable from motor to panel/starter) suitable for fitment with 5 cs. v.t axial/mix flow pump type vertical flange mounted as per approved specifications of the department., supply, erection & commissioning of fully automatic star delta starter of cap. 150 amp including all accessories as one incomer of mccb (150amp) with 1 no mcb for lighting load, contactor rating 120 amp, 90 amp, 70 amp with control transformer for control supply, outgoing indicator, having mpr & all types of protections i.e.uv/ov/ over current, phase imbalance/phase reversal protection, locked rotor, dry run etc, digital meters, push buttons, bus bars, capacitor bank, seperate relay for single phase protection etc. complete in all respect suitable for open fields operation of 1 no. motor of capacity of 30 hp with a stand of ms channel with canopy having suitable operating height above the kachha open fields as per approved specifications of the department. (suitable for voltage range 380 +- 10%,) panel should be outdoor type, supply, erection & commissioning of m.s delivery pipe 10" dia. made of ms plate both end flanged (equal to or less than 6 mtr length of pipe) as per approved specification & make. (including ss/ht nut & bolt, rubber packing & other fitment accessory required), supply, erection and commissioning of ms girder parallel flange section ismb 150 with primer and bituminous based paint inside & outside of length 4mtr (approx wt 60 kg per pc) as per approved make & conforming to is808:2021.
Tender For sitc of podcast video audio studio at dd news new delhi - 4k camcorder , memory card cfex card 256 gb or higher , camera tripod aluminium alloy fluid head myt801 , podcast microphone with boom arm stand , 42 inch 4k studio display with floor stand , sdi ndi converter bidirectional , studio backdrop 12 feet x 8 feet , video switcher with control panel hardware 4 ndi 4 hdmi 4k 4 iso recording cg virtual sets live streaming , equipment rack 42u 19 inch 1000mm video production desk , 27 inch full hd monitor for gui and multiviewer , nas storage 100tb ssd nvme dual 10gbe fibre 2 x 12gbps sas , av network switch 24 ports ndi poe min 4 ports 10gbps fibre , 12 port audio mixer with phantom power , professional headphone , audio monitoring amplifier speaker bi amp , laptop similar or better than macbook pro m5 32 gb ram 1 tb ssd 16 inch , pcr studio communication system , editing workstation similar or better than silicon m3 32 gb 1 2 tb ssd 4k display , fcp 10 perpetual license prasar bharati name , ups 20 kva with battery bank 20 min backup at full load , installation materials cables connectors conduits cable trays etc , sitc testing commissioning 3 day training charges , technical operation support minimum of 3 skilled persons in the shift to operate the supplied equipment 8 hrs per day for 3 months post commissioning , acoustic treatment studio 20 feet l x 18 feet w x 12 feet h wall panels ceiling clouds floor acoustic door 3 windows , studio riser 8 feet x 8 feet studio table for 4 guests 4 chairs studio backdrop , pcr table editing table 3 chairs , studio lighting grid key lights fill lights backlights cable management
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For supply, installation, testing and commissioning of accessories for 750v ac, 3-phase (ryb) plc controlled liquid load bank system comprising plc controller with hmi/touch screen; rf remote transmitter & receiver for remote operation; ss-316 stainless steel electrodes (3 sets, ryb) conforming to is 6911:2017; 3 hp clutch motor (electrode drive) and 3 hp water pump (circulation pump) conforming to is 4722 (rotating electrical machines); power contactor 40a (2 nos.), mpcb 32a (1 no.), isolator, mccb/acb, smps (24v dc); control panel with all internal wiring and programming software; temperature & level sensors (1 set each); cctv camera system (1 set); fresh water & circulation piping with pipeline & fittings (1 lot); earthing system (4 nos. copper earth plate with ss bolt) conforming to is 3043; installation materials and accessories; suitable for hog, lhb and generator testing applications in harsh environment; make: purushattam automation ltd.; hsn code: 9031 [ warranty period: 30 months after the date of delivery ] ]
Tender For three phase inductive load bank of transformer testing supply 415v ac, 4 wire, 50hz, maximum current 227a, resolution steps: 2 * 1 no, 10 amps * 1 no, 40 amps * 1 no, 50 amps * 1 no, 100 amps* 1 no, switchgears make: abb/siemens/schneider industrial ms enclosure with ventilation [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated ms enclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status