Get complete information related to latest Rcc Jali Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rcc Jali Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rcc Jali Tenders.
Tender For corrigendum : provision of compound wall with rccjali around officers md accn with stainless steel gate at icgs pipavav under ge i cg porbandar
Tender For supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sensors, annunciat
Tender For custom bid for services - provision of standby pump and associatedworks at main water supply pump house at af station samana-1. supply, installation and commissioning of submersible pump set 30 hp having discharge of 1650-500 lpm and head 47-78m electric driven 415 v, tp suitable open well (outlet size for 80*65mm dia) supply and install complete inclusive of 20 meter long 25 sqmm 3 core flat submersible cable, chain for supporting and taking out set mounting arrangement. nos 01, 2. supply, install, testing and commissioning and testing factory made and tested (including cpri type test certified) lt feeder pillar box (kiosk) outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 hz ac supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 350 amps rating installed on porcelain insulators. the panel shall be dust and vermin proof, made of 3.15mm crca ms sheet 75mm x 30mm thick ms channel frame, duly powder coated finish. front opening type with aprons for cable entry with double door shitter and locking arrangement, danger plate and earthing terminal. the scope of work includes pcc foundation and provision of the following :- incoming (a) mccb 4 pole 200 amps, 36 ka, 415 v - 01 nos (b) bus bar aluminum strip 400 amp, 4 pole, for in comp supply - 01 nos (c) digital panel meter including cts - 01 no outgoing (a) mcb tpn 40 amp 6 ka, 415 v 50 hz - 02 nos (b) mccb tpn 80 amp 16 ka, 415 v 50 hz - 01 no (c) star delta starter panel with suitable thermal overload protection, sppr, overvoltage, overcurrent and surge protection for 30 hp - 02 nos (d) low water level motor cutoff sensor with wire 20 mtr - 02 nos (make gic or slect control pvt ltd.). each 01, 3. supply and fix pressure guage upto pn-40 rating all as specified and as directed by engineer-in-charge. each 10, 4. supply and fixing hdpe pipe 90 mm dia pn 16 pressure rating with connected items all as specified and as directed by engineer-in-charge. rm 15, 5. supply and fix, gi sluice valve confirming to is 13095, 100 mm (4 ) dia with flanges end v all as specified and directed by engineer-in-charge., 6. material and labour in replacement for construction of valve chamber of size 1200 x 900 x 900 mm deep dimensions (over all internal dimension) for sluice valve etc. with pcc foundation, pcc block masonry walls, plastering, pcc coping, white washing, mild steel chamber cover, painting to chamber cover including excavation and earth work in any type of soil complete all as specified below :- valve chamber shall be provided with the following specifications :- (i) cement concrete for foundation (1:4:8) type d2 using 40mm graded stone aggregate 150mm thick extended upto 150 mm beyond the outer face of block masonry. (ii) walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20 mm graded stone aggregate) solid building blocks, setting in cm 1:6 complete. (iii) internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with cm 1:4 15 mm thick finished even and smooth. (iv) 50 mm thick coping in pcc 1:3:6 type c1 over block masonry wall. (v) entire plastered surfaces shall be treated with 3 coats of white wash. (vi) chamber cover shall be of 6 mm thick fiber reinforced polymer (frp) sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. steel furface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer. each 01, 7. supply and fix 100 mm non return valve conforming to is 13095, 100 mm (4 ) dia with flanges end all as specified and directed. each 02, 8. supply and fix galvanized iron heavy grade pn 16 rating y section with flanged end 2 openings 100 mm dia and one 180 mm dia with suitable flanges and bots flanges end v all as specified and directed. kg 25-msme exemption - yes | startup exemption - yes
Tender For corrigendum : manufacturing of 8 meter/200 kg working load readymade, prestressed concrete (psc) poles from in-house pgvcl pole factory at shapur (junagadh) to be supplied under pgvcl for 2 (two) years
Tender For supply of badminton court construction of concrete floor labour installation charge , interlocking modular tiles sports flooring for badminton court , movable badminton pole , badminton net , led flood light with pole and complete electric fitting , referee chair for badminton , seating chair 3 seater
Tender For supply of solar powered led light with inbuilt battery 12.8v 48ah , solar panel with stand 12v 165w 1485 x 665 x 35 mm , gi pole 76mm 6 mtr with 1.6 to 1.8 mm thickness , gi single arm dia 45 mm length 500mm 1.6 to 1.8 mm , cement and concrete material with installation
Tender For construction work of cement concrete road with tri-mix, paving block footpath and l.e.d. street light fixture with pole as per various location chart at, keshod dist: junagadh under swarnim jayanti mukhya mantri saheri vikash yojana (og grant) year-2023-24
Tender For certain maintenance work under ge east jabalpur - m & l for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m high from (above grnd 7.5rm) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing pole no. of suitable size of letters as directed. note : size of lettering and colours of paints will be directed by engr-in-charge., m & l for painting carefully (by taking necessary shut down from respective sub-station) on lt pcc pole 9 m high from (7.5 metre above natural ground ) upto top of the pole, applying two coats of cement base paint over a coat of alkalines resistant primer to surface of concrete pole with cement based paint after preparation of surfaces of poles including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing pole no. of suitable size of letters as directed. note : size of lettering and colours of paints will be as directed by engr-in-charge., diasmantling of acsr or aac conductors of any size from lt poles or distrubution span of complete all as specified & directed., fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of aacsr/aac/lt over head conductors of any size with and including 14 swg binding wire and testing, complete all as specified & directed., m&l for acsr conductor lt (6 in 1) weasel type ,restringing and fixing it properly in between poles and connecteing it with insulator properly all as per required and directed by engg in chrge, dismantling gi wire of any size from lt poles or distribution span & removal from site, complete all as specified and directed., fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of galvanised steel wire 3.15 or 4 mm dia lt over head earth wire, complete all as specified & directed., m&l for over head galvanised steel wire 3.15 or 4mm dia on existing lt poles and stretching and then strengthening including binding & jointing the conductor and testing complete all as specified and directed., m & l for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps, bolts and nuts of approved size, for lt, 20x15cm size complete all as specified and directed., dismantling old unserviceable insulators of any type including ms spindles, gi washers, nuts etc and s&f shackle type, porcelain, vitreous, white/brown or green insulator including galvanised mild steel straps(31x5mm), two gi washers & one gi nut, 100 mm height and 115 mm dia(max) suitable for working pressure 1100 volts grade, complete all as specified and directed., s&f pvc separator 2 way for lt overhead electric line complete all as specified and directed., s&f pvc separator 4 way for lt overhead electric line complete all as specified and directed., supply and fix, erection steel tubular swaged poles type 410 sp-31 (9 meter long), painting with two coat of aluminium paint over one coat of red oxide primer and marking pole nos with black sythetic enamelled paint including tarring one coat of steel surface embedded in concrete complete excluding earth work and pcc work and taking out old unserviceable lt pole complete all as specified and as directed., dismantling lt steel tubular poles and setting aside for re-use within 50 metres complete all as specified and directed.