Tender For piped water supply scheme with rcc over head tank under jal jeevan mission (jjm) at village- charki, bhaisahud, dauadol and naya tola , sub division-deosar distt- singrauli (m.p.)
Tender For corrigendum : (7th call) construction, testing and commissioning of r.c.c. elevated service reservoir of 40 kl capacities & staging 16 mt. including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber &providing, laying, jointing, interconnection of 90mm dia, 75 mm dia to 63 mm hdpe pe-100 , pn-6 pipe & …. mm dia upvc class 6 kg/sqcm with suitable joints & 65 mm dia gi pipe, valve specials and all fittings including all allied civil works, supplying & installation of energy efficiant five star bee rating isi marked required capacity single phase, 50 hz, 220v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, ss /nylon wirer opeand connection cable including verification of tubewell yield& electric connection from cseb, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(f.h.t.c) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under single village of piped water supply scheme under jal jeevan mission for village purantarai block dantewada, district – dantewada निविदा में (p.h.e. sor (01.06.2020) दिनांक 30-03-2021 तक संशोधनों सहित लागु होगा
Tender For corrigendum : (7th call) construction, testing and commissioning of r.c.c. elevated service reservoir of 40 kl capacities & staging 16 mt. including providing and fixing of ci double flange pipe, double flange specials & di double flange soft seated sluice valve including construction of suitable r.c.c. valve chamber &providing, laying, jointing, interconnection of 90mm dia, 75 mm dia to 63 mm hdpe pe-100 , pn-6 pipe & …. mm dia upvc class 6 kg/sqcm with suitable joints & 65 mm dia gi pipe, valve specials and all fittings including all allied civil works, supplying & installation of energy efficiant five star bee rating isi marked required capacity single phase, 50 hz, 220v, deep well submersible pump stainless steel body, suitable for 4"/6" tube well with contral panel starter suitable for submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe, ss /nylon wirer opeand connection cable including verification of tubewell yield& electric connection from cseb, construction of brick masonry switch room of size 1.2*1.2*2.1 mtr ,construction of boundary wall around the over head tank, installation of 01 no. electro chlorinator , construction of chlorinator room of size 2.4*2.4*3.0 mtr , providing functional household tap connection(f.h.t.c) in individual households and government instiution etc. complete with trial run operation & maintanance for 06 months under single village of piped water supply scheme under jal jeevan mission for village badegodre block dantewada, district – dantewada निविदा में (p.h.e. sor (01.06.2020) दिनांक 30-03-2021 तक संशोधनों सहित लागु होगा
Tender For corrigendum : 82645/e8 provn of station gym at af stn thanjavur - general summary (note : schedule a part i building/ structure is not pre priced by mes and the pre priced rate indicated as "rs. 0.00" under col.5 signifies this fact only. bidder shall insert their rate in green field under column 6), schedule a part i building/structures design and construction of rcc m-25 framed structure (single storey) with permanent specifications in rcc m-25 with brick masonry panel walls, att, pu based wpt, earthquake resistance as per latest is etc incl rcc foundation etc complete all as specified and as shown in architectural drawing / approved structural drawing.note:- the contractor shall submit structural design & drawing of the building under sch a part i (prepared based on architectural drawing forming part of tender document) duly vetted by any iit / nit or any govt engineering college within the time limit shown in schedule a notes., general summary (note : schedule a part ii to v are prepriced by mes under ser no. 04 to 07. bidders shall insert their lumpsum amount in the green coloured field under col-6 only), total of schedule a part ii internal electrification , total of schedule a part iii internal water supply", total of schedule a part iv road / hard standing", total of schedule a part v sewage disposal , sch a part- vi - miscellaneous items (note : this schedule is not pre priced by mes and the pre priced rate indicated as "rs. 0.00" under col.5 signifies this fact only. bidder shall insert their rate in green field under column 6), m&l for on site lldpe septic tank for 25 users capacity designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation,vent shaft, connection etc., complete all as specified and as directed., m&l for soakage well 2.4m dia x 4.5 m effective depth with cover in any type of soil , foundation in pcc 1:3:6, walls of honey combed masonry with top ring of m25 concrete including intercepting chamber and screen chamber made of brick masonry in cememt mortar, rcc cover slab in m25 cover, interconnecting pipes of rcc/dwc complete filled with brick bats complete all as per ce af bangalore td drg no afb/td125 sheet no 1/2 and 2/2 and ce a&n zone drg no ce/td/2022/16 steet 1/1., s&f turbo force wall mounted fans complete with blades and accessories, 230 v, 450 mm sweep five star rated including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by engineer-in-charge.
Tender For corrigendum : water proofing of terrace and replacement of damaged rcctanks with smc tank inlcuding replacement of g.i. pipe line & fittings at block-3 at cgo complex, lodhi road, new delhi.