Get complete information related to latest Rcc Pipeline Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rcc Pipeline Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rcc Pipeline Laying Tenders.
Tender For work of providing and laying of 200mm dia dwc pipe line with construction of new machineholes on northern side of jbn main road from bangalore one office to blind school road and on southern side of jbn main road from bwssb water tank to traffic police station all along foot path coming under jeevanbheemnagar service station of aee se-4 sub-division.
Tender For construction and laying sewerage line of rabindra angan hall bidhannagar, with dwc pipe within sector - iii, under bidhannagar municipal corporation.
Tender For supply of extending ncn connectivity to new admin building andat mi room and ims at ins baaz - supply of single mode optical 12 f armoured , hdpe duct pipe , joint closure , supply of rcc chamber , otb installation and supply , electrical conduit 32 mm , 32 mm capping and casing of ibd work , ground cable 1cx4 sqmm , supply installation and commissiong of 3cx2.5 sqmm power cable , apc e 2000 patch cable , lucent connector , supply installation and commissiong of back box and face plate , category 6 utp and abd , two port i o , corrugated tube , dwc pipe 70 mm , single mode fusion in 02 nos otbs , single mode optical laying in pipe , structure of category 6 utp laying , integration and commissioning of access switches with existing cucm , pipe laying via open trenching , concrete working
Tender For "design, manufacture, supply, installation, testing & commissioning of microprocessor based electronic interlocking system (with inbuilt block instrument in ei) (rdso spec no. rdso/spn/192/2019 ver. 2 with latest amendment) at badi sadri (alteration, indoor & outdoor work), jaloda jagir, chhoti sadri, narani, nimach (outdoor work only) stations along with supply, installation, testing and commissioning of various indoor & outdoor signaling & telecom systems/gears. the work includes addition/alteration in the existing electronic interlocking (kyosan make ei ) at badi sadri station (alteration in existing kyosan make ei & associated indoor and outdoor works) and outdoor work at nimach station in c/w new bg line in nimach-badi sadri section. the work includes excavation of trench, laying of cables in rcc half round pipes/gi pipe/dwc/hdpe/trench etc., casting of foundations of macls signals/apparatus cases, supply-installation of point machines, apparatus cases, macls signals, electric lifting barrier along with emergency slide boom, track circuit equipment (dc track circuit & single msdac in all stations yards ), earthing, data loggers, eld, facs, afdas, iot based rdpms etc. the work also includes signaling and telecom work for shifting of existing s&t gears (lc gates, signals and location boxes, s&t cables, hassdac, etc.) for removal of infringements of s&t gears coming in alignment in c/w new bg line in nimach-badi sadri section.the telecom work includes design, supply, installation, configuration, testing and commissioning (sitc) of telecom indoor and outdoor equipment including ip-mpls system with power supply arrangement, trenching, laying, jointing and termination of 4x48 fibre optical fiber cable (two on each side of the track) cable and 6 quad cable along with provision of passenger amenities and other telecom works at stations, block sections, tss/sp/ssp etc. in c/w new bg line in nimach-badi sadri section of ajmer division of north western railway".
Tender For supply of taking down of light fittings of any type size and model complete all as specified , taking down of brackets of any type size and model complete all as specified , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug , m and l in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , s and f in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f cable junction box 155x210x92 mm in size, made out of thermoplastic having ip 66 protection for outdoor installation fixed with 4 way , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , taking down out unservicable or servicable ug cable of any cross section area and connection etc. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth , returning filling in including spreading, levelling watering and well ramming in layers not exc. , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , s and l for cable in trenches or passing through pipe, xlpe insulated 25 sqmm 4 core. , s and l for cable in trenches or passing through pipe, xlpe insulated, heavy duty, galvanised steel strip or wire armoured electric lt cable 10 sqmm 4 core. , re laying fixing or passing through xlpe insulated armored electric power ug cable etc. , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed . , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia under road foot path, not exc. 10.00 mtr , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection and connection of cable. , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above , m and l sand cushioning dry in trenches for protection of ug cables below above and around the ug cable , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , supply and laying for cable in trenches or passing through pipe xlpe insulated 25 sqmm 4 core. , supply and laying for cable in trenches or passing through pipe xlpe insulated 10 sqmm 4 core. , re laying fixing or passing through pipe xlpe insulated armoured electric power ug cable heavy duty with aluminium conductor , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia under road foot path not exc. 10.00 mtr , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases , s and f crca sheet steel duly phosphatized and powder coated with 7 tank process wall pole mounted floor , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of taking down of light fittings of any type size and model complete all as specified , taking down of brackets of any type size and model complete all as specified , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , s and f in repair led street light fitting 120 watt 230 v ac outdoor type with high pressure die cast aluminum hosing. , s and f in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics and equipped , s and f in repair led flood light 150 watt 230 v ac outdoor type with thermal management in multiple optics and equipped with ip66 protection , s and f cable junction box 155x210x92 mm in size made out of thermoplasti having ip 66 protection for outdoor installation fixed with 4 way bakelite cable terminals , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees bends elbows , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm , removing excavated materials soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above , m and l sand cushioning dry in trenches for protection of ug cables , m and l for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of ug cable , s and l for cable in trenches or passing through pipe xlpe insulated wire armoured electric lt cable 25 sqmm 4 core. , s and l for cable in trenches or passing through pipe xlpe insulated heavy duty galvanised steel strip or wire armoured electric lt cable a 10 sqmm 4 core. , relaying fixing or passing through pipe xlpe insulated armoured electric power ug cable heavy duty , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore dia , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate as in coping for pole including form work and finishing , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , s and f hdpe dwc double walled corrugated of diameter 25 mm including disconnection and connection of cable , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , wrecking crow bar or claw bar as per is 706 (q3)
Tender For supply of taking down of light fittings of any type size and model complete all as specified. , taking down of brackets of any type size and model complete all as specified and directed. , m and l in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts , m and l in repair steel tubular swaged poles complete with cast iron base plate , re fixing of led street light fittings of any wattage outdoor type complete all as specified and directed. , supply and fixing in repair led street light fitting 120 watt 230 v ac outdoor type , supply and fixing in repair led flood light 80 watt 230 v ac outdoor type with thermal management in multiple optics , supply and fixing in repair led flood light 150 watt 230 v ac outdoor type with thermal management , s and f cable junction box 155x210x92 mm in size made out of thermoplastic aving ip 66 protection , supply and passing through steel tubler pole service connection 1100 volts grade multicore fr round insulated copper conductor , s and f single arm bracket made of 40mm dia 1.0mtr long for security light with mounting ms clamp , s and f in repair rigid non metallic pvc conduit of dia 20 mm exclusive of boxes junction terminal , m and l for earthing complete with ms galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs , taking down out unserviceable or serviceable ug cables of any cross sectional area and connections including bricks gi pipe etc. , excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth taking out and laying of cables etc. , returning filling in including spreading levelling watering and well ramming in layers not exc. 250mm in soft loose soil complete all as specified , removing excavated materials soils not exc. 50.00 mtr , m and l sand cushioning dry in trenches for protec tion of ug cables , m and l for fly ash bricks locally available laid dry width wise across the line of cable , supply and laying for cable in trenches or passing through pipe xlpe insulated heavy duty , supply and laying for cable in trenches or passing through pipe xlpe insulated 10 sqmm 4 core. , re laying fixing or passing through pipe xlpe insulated armoured electric power ug cable 10 sqmm 2 core to 25 sqmm 4 core , s and f 40 mm high density polyethylene pipe hdpe of pressure rating 6 kgf cm2 fixed complete to walls , s and f galvanised iron pipe 40mm bore dia light grade for protection of ug cable laid in floors , labour only for horizontal boring for passing protection pipe up to 80mm bore , m and l for pcc 1.2.4 type b1 using 20 mm graded aggregate , m and l for pcc 1.3.6 type c2 using 40 mm graded aggregate as in foundation for pole etc complete , s and f hdpe dwc double walled corrugated of diameter 25 mm including , m and l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , crimping tools (q3)