Get complete information related to latest Rcc Pole Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rcc Pole Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rcc Pole Tenders.
Tender For restoration of rain damages to gwss bahli khanewali in gp bahli tehsil rampur distt. shimla hp (sh:-dismantling of rcc storage tank 20000 ltr cap at village khanewali and construction of 1 no. rcc storage tank 25000 ltr cap with barbed wire fencing and construction of retaining wall to protect storage tank
Tender For corrigendum : supply of aaa insulated conductor size 7 by4.39mm pvc insulated , gi c-type channel 75mmx40mmx10mm x3metre , gi f- cross arm , gi v-cross arm , pin insulator 11 kv , disc insulator 11 kv , gi stay set ht suitable for 11kv line , gi earthing electrode pipe 40 mm dia , gi clamp as per drwg 93 sl no-1 , gi clamp as per drwg 93 sl no-2 , gi clamp as per drwg 93 sl no-3 , gi clamp as per drwg 93 sl no-4 , gi clamp as per drwg 93 sl no-5 , gi nut and bolt ft with 2 plain washers m16x75mm , gi nut and bolt ft with 2 plain washers m16x100mm , gi nut and bolt ft with 2 plain washers m16x150mm , gi nut and bolt ft with 2 plain washers m16x200mm , gi nut and bolt ft with 2 plain washers m16x250mm , rccpole 9 mtr , cable route marker , silica gel blue 9-12 mm size with air tight container , petroleum gelly
Tender For manufacturing 700 nos. of 30feet (9.14 mts.) rccpoles in the pole casting yards at head office (100 nos.), kattukuppam (200 nos.) and marapalam (400 nos.) pole casting yards, electricity department, puducherry
Tender For corrigendum : supply of pcc for pedestal , providing,mxng and plcng,rcc,1 is to 2 is to 4mix , structural steel , excavation in earth upto1.5mt,wbackfill , reinforcement steel , sply and lay of earth stripfixacc,25x3mm , sply layg of cable tray duct,gi,150mm , non flp 4k camera , box camera perimeter camera , hd ip camera mp2,flp enclosure , fixed non-flp camera , sply and instln of camera dome camera,te , sply and instln of ptz camera , server for cctv system , sply and instln of software cctv vms , video storage sys cctv sys , network server rack,42u , sply and instln of workstation client , sply and instl of 55in led tv , 8 port poe l2 n w switch , 12 port poe l2 nw switch , sply and instln of flp jb , liu , sply and instln of gi pole ht 9mt , sply and fixg of armoured cable size 3cx4mm2 , sply and layg cat6 network cable armoured , cat6 cable, n arm wpvc casing , sply and instln ofc cable armoured,6c , sply and layg of earth wire frls,cu,4mm2 , pipe,gi,is 1239,erw,50mm , exca for cbl trenchunderground,1000mm,10 , back filling of cable trench w , camc - 1st year post , camc - 2nd year post , camc - 3rd year post , camc - 4th year post , camc - 5th year post
Tender For land slide mitigation on kullu manali left bank road near chachoga at km. 52/00 to 52/430 tehsil manali distt. kullu hp mdr-29-sh metalling and tarring pcc r/wall with rcc r/wall, wire crated r/wall, b/wall, hume pipe culverts, u-shape drain and cras
Tender For special repairs of sfc at nay goa and replacement of old deteriorated rccpole overhead line to underground cable and octagonal pole including provision of lightning arrester with earthing for building p482 at nasdo goa under age em i of ge nw vasco
Tender For removing, shifting and re-erection the electrical substation equipments from 6th berth s s to proposed location thereof inside cargo jetty area - removing & shifting of the following equipments as per tech spec. no:-1, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit., lt panel ( way-15), re-erection, testing & commissioning of the following equipments as per tech. spec. no. 2, 500 kva distributions transformer., rmu of 12 kv, 630 amps 21 ka outdoor mounted rmu unit, supply at site 3 core armoured ht aluminium conductor xlpe cable of 11 kv grade, following rating of the as per technical specification no. 3 a). 3c x 150. sq. mm., supply at site 4 core armoured lt aluminium conductor xlpe cable of 1.1 kv grade, following rating of the as per technical specification no. 4 a) 3.5c x 300 sq. mm., supply, installation testing & commissioning at site of following 11-way lt load point panel (as per proven design) as per technical specification no. 511 ways {2 i/c, i changeover (bus coupler), 8 o/g}., laying ht/lt armoured aluminium conductor cable 3.5/4 core up to 35 sq. mm. to 150 sq. mm. as per technical specification no. 6, through hdd, with hdpe heavy duty pipe., in existing rcc trench, hard & soft soil, supply at site following way lt distribution panel (as per proven design) as per technical specification no. 715 ways (2 i/c, 1 bus coupler, 12 o/g)., installation, testing & commissioning of lt distribution panel as per technical specification no. 8, providing & connecting following type of earth wire from earth station to equipment as per requirement as per tech. spec. no. 9, 25 x 3 mm. copper strip, 25 x 3 mm. hot dip gi strip., 8 swg gi earthing wire, supply & preparation of earthing station, tfc, chemical treated back filled compound earthing system as per technical specification no. 10a) pipe-in-pipe 50-60 mm. dia. gi type 3 mtr. depth, for transformer body earth, maintenance free, supply of 3 phase 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 11, installation, testing & commissioning of 500 kva 11/0.433 kv indoor type distribution transformer as per technical specification no. 12, supply of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 13, fixing of tpn double door ip 42 db 4 ways distribution board as per technical specification no. 14, supply of following type of mcb as per technical specification no. 15, 40a tpn mcb with 10ka breaking capacity, 32a sp mcb with 10ka breaking capacity, fixing of tpn/sp mcbs with 10 ka breaking capacity as per technical specification no. 16, providing & fixing of surface wiring with 2 x 2.5 sq. mm. copper conductor with pvc insulated (single phase and neutral) for single phase sub-circuit from the db/mcbs to the switch board as per technical specification no. 17, providing and fixing surface wiring with 1.5 sq. mm. copper conductor for light /tube point with pvc insulated single core standard copper conductor wire as per technical specification no. 17, providing and fixing surface wiring for 20a & 10a, 240 volt, 50hz power point as per technical specification no. 19, supply & installation of surface mounted 20 watt led tube light luminary complete with batten as per technical specification no. 20, supply at site 300mm sweep exhaust fan as per technical specification no. 21, fixing of 300mm sweep exhaust fan as per technical specification no. 22, supply of heat shrink straight through joint kit for 11kv, 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 23, fixing the heat shrink straight through joint kit for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no.24, supply of heat shrink long sleeve & boat, suitable for rmu end termination kit (indoor type) for 11kv 3c x 150 sq.mm h.t xlpe cable as per technical specification no. 25, fixing of heat shrink long sleeve & boat, suitable
Tender For construction of damaged b.wall in fluding of rain water by rcc retaining wall, protection wall, raising of b.wall with concertina wire and other misc.civil work due to damaged in fluding of rain water at 33/11 kv s/s peeplu.