Get complete information related to latest Refrigerant Pipe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Refrigerant Pipe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Refrigerant Pipe Tenders.
Tender For corrigendum : supply of 10 hp vrf outdoor unit , 12 hp vrf outdoor unit , 14 hp vrf outdoor unit , 0.8 tr indoor unit , sitc of 1.0 tr indoor unit , sitc of 1.6tr indoor unit , sitc of 2.0 tr indoor unit , sitc of 2.6 tr indoor unit , sitc of 3.2 tr indoor unit , sitc of 4.0 tr indoor unit , sitc 4.6 tr indoor unit , supply installation testing and commissioning of wireless remote controller , sitc of following copper fittings to be provided in refrigerantpipe line t joint , sitc of following copper fittings to be provided in refrigerantpipe out door connection kit , supply of 1.9 tr inverter ttpe split ac with wireless remote , supply of 1.5 tr inverter ttpe split ac with wireless remote , copper pipe 41.3 mm , copper pipe 34.9 mm , copper pipe 28.6 mm , copper pipe 22.2 mm , copper pipe 19.1 mm , copper pipe 15.9 mm , coper pipe 12.7 mm , copper pipe 9.5 mm , copper pipe 6.4 mm , normal split copper pipe , pvc drain pipe 25mm dia , pvc drain pipe 32 mm dia , pvc drain pipe 40 mm dia , sitc of microprocessor based communication cable , hot dipped gi perforated 20 guage tray 450mmx75mm x 1.6mm thickness , hot dipped gi perforated 20 guage tray 300 mmx75mm x 1.6mm thickness , hot dipped gi perforated 20 guage tray 200 mmx75mm x 1.6mm thickness , hot dipped gi perforated 20 guage tray 150 mmx75mm x 1.6mm thickness
Tender For supply of c73340100470 supply of cassette ac four way of 2tr capacity, minimum 5 star rating inverter type refer annexure iii , c73340000754 supply of split ac of 2tr capacity, minimum 5 star rating inverter type rotary or scroll compressor refer annexure iii , c73340001239 supply of window ac of 1.5tr capacity, minimum 5 star rating inverter type rotary or scroll compressor refer annexure iii , 100000000000 supply of refrigerant grade copper piping between indoor and outdoor units of suitable size refer annexure iii , 100000000001 supply of 4 core 2point5 sqmm flexible copper power cable with all fittings refer annexure iii , 100000000002 supply of cpvc sdr11 pipes of 25 mm dia with 9mm nitrial insulation refer annexure iii , 100000000003 supply of cpvc sdr11 pipes of 32 mm dia with 9mm nitrial insulation refer annexure iii , 100000000004 supply of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerantpipes refer annexure iii , 100000000005 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness refer annexure iii , 100000000006 installation,testing and commissioning of cassette ac four way of 2tr capacity, minimum 5 star refer annexure iv , 100000000007 installation,testing and commissioning of split ac of 2tr capacity, minimum 5 star rating inverter type rotary refer annexure iv , 100000000008 installation,testing and commissioning of window ac of 1point5tr refer annexure iv , 100000000009 erection, testing and commissioning of refrigerant grade copper piping between indoor and outdoor units of suitable size refer annexure iv , 100000000010 laying of 4 core 2point5 sqmm flexible copper power cable with all fittings refer annexure iv , 100000000011 laying of cpvc sdr11 pipes of 25 mm dia with 9mm nitrial insulation refer annexure iv , 100000000012 laying of cpvc sdr11 pipes of 32 mm dia with 9mm nitrial insulation, for condensate water drain refer annexure iv , 100000000013 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm refer annexure iv , 100000000014 installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1oint6 mm thickness refer annexure iv , 100000000015 dismantling and shifting of existing split,cassette and window ac total 21nos refer annexure iv
Tender For corrigendum : providing and laying 250mm and 300mm dia. s.w. pipe sewer line and 150mm and 100mm dia water supply line in inder nagar wali gali and adjoining streets , a-block dabua colony in ward no.11, nit faridabad.
Tender For replacement of old/damaged sewer line by p/l 300mm sn8 pipe near rz 14/335 jagdama vihar to ahuja apartment, manglapuri 119 ward under dwarka constituency under ee(d)-25.
Tender For restoration of rain damages to sewerage scheme mandi town in tehsil sadar distt. mandi (hp).(sh:-providing, laying, jointing and testing of hdpe pipe 315 mm dia pe 80 pn 6.00=200 rmt. at sain curve for temporary restoration of main sewer line).
Tender For work of conducting detailed survey of closed drains primary and secondary drains to stop the flow of sewage and providing, laying 300mm dia dwc and 230mm dia sw pipe line to avoid direct entry of sewerage into dasarahalli lake and linking existing sewer line to sub main inside swd at various locations pertaining to aeenw-2 sub division
Tender For restoration of settled/damaged 300 mm dia. about 12 ft. deep sewer line by static pipe bursting method (pentode system) at d-54 in fateh nagar in ward no 100, in hari nagar constituency ac-28 under ee(c)-23
Tender For dnit for providing and laying of new and rehabilitation sewer line of 200mm upvc pipe at baba deep singh gurudwara wali gali at ajnala district amritsar