Tender For supply, erection and commissioning of 300 nb quick filling / interconnection pipe line & fittings for cooling water tunnel of unit ii to iii in cwph-i note:1. prospective bidders may get the specification free of cost by downloading from websites.tancedco : www.tancedco.gov.innic : https://tntenders.gov.in/nicgep/apptn govt. : http://www.tender.tn.gov.intender opening (electronically):o/o the superintending engineer/p&a/ttps tuticorin. (executive engineer/mm/ttps)
Tender For corrigendum : supply-ac and ventilation system-air conditioning unit with free cooling of 3tr capacity with microprocessor based controller-for pgcil mandsaur new , supply-ac and ventilation system- air conditioning unit with free cooling of 4tr capacity with microprocessor basedcontroller- for pgcil mandsaur new , supply-ac and ventilation system-split ac unit -2 tr-for pgcil mandsaur new , supply-ac and ventilation system-copper refrigerant piping including insulation-for pgcil mandsaur new , supply-ac and ventilation system- controller-for pgcil mandsaur new , supply-ac and ventilation system-air conditioning unit with freecooling of 4tr capacity with microprocessor based controller-for pgcil indore extn , etc-ac and ventilation system-air conditioning unit with free cooling of 3tr capacity with microprocessor based controller -for pgcil mandsaur new , etc-ac and ventilationsystem-air conditioning unitwith free cooling of 4tr capacity with microprocessor basedcontroller-for pgcil mandsaur new , etc-ac and ventilationsystem-split ac unit -2 tr-for pgcil mandsaur new , etc-ac and ventilationsystem- copper refrigerant piping including insulation-for pgcil mandsaur new , etc-ac and ventilationsystem- controller-for pgcil mandsaur new , etc-ac and ventilation system-air conditioning unit with freecooling of 4tr capacity with microprocessor based controller-for pgcil indore extn bid number/ & ( * ) : gem/2025/b/5801423 dated/ + : 10-01-2025 bid document/ 2 2 1 / 13
Tender For procurement of machinery/equipment for institute of veterinary biologicals - microscope :head: binocular 30 . 360 rotating. 48-75mm interpupilar. +/- 5mm diopter on left tube, objective magnification:semi plan 4x/0.10, 10x/0.25, s40x/0.65, oil immersion objectives, eyepiece magnification: wf 10x/18mm, -80 c ultra low temperature freezers:temperature range : -60 c to -86 c, volume : 528 l, compressor capacity 950w, compressor type/brand/number-hermetic reciprocating type / secop / 2, condenser type- enhanced micro-channel & forced-air cooled, defrost method-manual, evaporator type-cold wall with enhanced heat transfer treatment refrigeration system type-direct cooling, refrigerated centrifuge machine :max. speed 16000 rpm, rotor : 1.5 ml/ 2 ml. , 15 ml. & 50 ml., freeze dryer machine: condenser temperature : -40 c, freezer drying area : 12 liters (0.118m3), condenser capacity : 3 - 5 ltr /24hrs., vacuum degree : 10 pa, drying chamber (ss-304) : stainless steel 230mm (dia) x 285mm (d), cold trap dimensions : (ss-304) 230mm (dia) x 230mm (d), vacuum probe :electric vacuum transducer, vacuum indicator :digital vacuum indicator, vacuum seals : made of silicon rubber, ultra ultimate vacuum (pump head) :1x 10 torr, vacuum pump direct drive motor rotary vane type vacuum pump of double stage with air ballast having ultimate vacuum of 1x10-2 torr on pump head, manifold/numbers of ports : one manifold with 8 ports,ability to hold flasks :1000ml, 500ml, 250ml, 100ml., ambient conditions :ambient temperature 25 c (ac room), voltage :220v, 50hz, power : 1400w, co2 incubator :capacity (english) 6.5 cu. ft., certifications/compliance ul, cul, ce, data outputs usb, and optional 4-20ma, description single tri-gas 184l incubator, 1-20%, capacity (metric) 184 l, chamber material polished stainless steel, co2 concentration range 0 to 20%, co2 sensor technology tc sensor, lighting led, material stainless steel, oxygen control 1 to 20%, relative humidity 90% at 37 c, temperature range (metric) ambient +5 to 50 c, type co2 incubator, dimensions (d x w x h) interior 20.0 x 21.3 x 26.8 in. (50.8 x 54.1 x 68.1 cm), dimensions (l x w x h) 25 x 26 x 39.5 in. (63.5 x 66 x 100.3 cm), weight (english) 365 lb. electrical requirements 230 v, 50/60 hz, voltage 230 v, unit size each, laminar flow ( vertical ):inner working size : 2 ft x 2 ft x 2 ft. with hepa filter., blower system: - direct drive, continuous duty hp with sealed bearings motors selected for energy efficiency, compact design, and flat profile. completely integrated assembly optimizes motor cooling. all rotating parts balanced for smooth, quiet and vibration-free operation. pre filter system: washable type pleated pre-filter with 90% efficiency is provided. hepa filtration system: - aluminium framed high efficiency particulate air (hepa) filter operate a typical efficiency of 99.97% at 0.3 micron size, provides superior product protection. material of construction: 18 gauge mild steel (ms) material with working area ss non corrosive material., dry bulb thermometer:temperature range -10 to 50 degree celsius, vortex mixer : vortex mixer (adjustable speed), with standard cup top, 115v/60hz, speed 0-2500rpm; orbit 4mm; touch or continuous operation; shade pole motor; analog control, auto filling machine:glass/plastic type of product; 2400 bottle/hr production;50-100 ml filling volume, auto capping machine:round type container; screw cap; 40 bottles/minute production, auto labelling machine:stainless steel finish; round bottle type ; bottle size -30 ml to 500 ml; cold dextrin base glue; 150 labels/minute;, mini cooler :20 c mini cooler with gel filled cover, code-525062, places-32, capacity-1.5, tissue homogenizer:interface-touch screen interface, programmable assays- up to 12 manual assays saved to memory, pre- defined assays- 73 pre-defined and optimized assay programs,time range- 1 to 120 seconds in 1 second increments, speed range- 4 to 10 m/sec in 0.5m/sec increments, cycles- 1 to 9 cycles
Tender For supply & installation of air cooled cooling type full scroll compressor vrf outdoor unit (30 hp) & indoor unit of (four way cassettes 3.2 tr-6 nos.), hi wall 2tr -2 nos. along with complete copper piping, gas charging, ms stand, drain piping and control cables, input supply cabling including cable supply from main panel to outdoor unit etc. , demand for supply of double door refrigerator for running room ujjain atctcc-ujnspecification is as under330 l 3 star frost free double door refrigerator. material should be of samsung, lg gudrej ex. withwarrenty of 05 years.remarks- material must be delivered at ctcc-ujjain , domestic refrigerator confirming to is 15750 (2006) capacity: 300 litres, type of door :- vertical type, double door. bee star rating:- 4 to 5., coil material: copper, compressor: power saver compressor, eco friendly refrigerant: yes. , 330 l 3 star frost free double door refrigerator , supply of inverter refrigerator 300 ltrs. capacity frost free double door refrigerator with 5star rating, warranty 10 year on compressor & 1 year on refrigerator make- lg, samsung, haier, voltas, whirlpool, kelvinator , supply of inverter refrigerator 185-190 ltrs. capacity with single door refrigerator with direct cool 5star rating, warranty 10 year on compressor & 1 year on refrigerator make- lg, samsung, haier, voltas, whirlpool, kelvinator, godrej , supply of inverter refrigerator 100 ltrs. capacity with single door refrigerator with direct cool 5star rating, warranty 10 year on compressor & 1 year on refrigerator make- lg, samsung, haier, voltas whirlpool kelvinator
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and