Get complete information related to latest Refrigerator Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Refrigerator Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Refrigerator Repair Tenders.
Tender For group-a pharmacology flicker fusion apparatus digital hand dynamometer digital display multiple choices reaction time apparatus peg board (purchase and groove) and hand stabilometer exercise physiology / gas analyzer with treadmill, bicycle ergometer treadmill with exercise physiology system master two steps autonomic function test lab (beat-to-beat haemodynamic monitoring system) platelet aggregation profiler (aggregometer) 16-channel polygraph portable hand held doppler atomic absorption spectrophotometer (aas) biochemical autoanalyzer fully automated cell counter ice- lined refrigerator (minus 20 degree) uv-visible spectrophotometer kits and solvents biosafety cabinet cooling centrifuge co2 incubator culture plates and glasswares autoclave media filtration system refrigerator rt-pcr autoclave feed sterilizer compound microscope with camera and recording system table top anesthesia system individually ventilated cage (ivc) ro water purifier portable usg machine portable x-ray machine lc-ms/ms enzyme multiplied immunoassay technique extraction equipment ? solid phase extractor, liquid phase reagents and solvents ice-lined refrigerator (minus 20 degree) semi-autoanalyzer
Tender For regular upkeep of double beam atomic absorption spectrophotometer along with ultrapure water generator uninterrupted online power back-up system present in different water testing laboratories throughout the state related to water quality monitorin
Tender For supply of repairing service of store and training equiptments - repair of generator , repair of ro , repair of photo copier , repair of water dispenser , repair of office wheel chair , repair of refrigerator , repair of grass cutter , repair of room heater
Tender For provision of 04 x fd ops room- work for 01 x fd ops room. the work consists of manufacture and supply of prefabricated mob ops room (veh mounted) of size 5.4.m x 4.80 m upto height of 2.44m and the shelter will consist of the fwg :- 2. 3. (a) the shelter would be of size 18 ft x 8 ft x 8 ft mounted on als extendable & extractable to provide hall of size 16 ft x 18 ft x 8 ft covered on three side with on end open (ref drawing no. 6) 4. 5. (b) the shelter should be mounted on flat bed als of size 16 ft x 8 ft (c) the shelter should be prefabricated and should have foldable wings for roof, floor and walls to provide a hall of size 5.4m x 4.80m x 2.44m i.e (18 ft x 16 ft x 8 ft) when all wings panel completely opened and on side of the same not enclosed. (d) opening and closing of wings should be operated through winches system manually. the base panel wings should be supported by adjustable manual jack system. (e) mechanism of opening or closing of wings will be based on operation of winches supported with manual jack system, to be functioned as under:- (i) opening the wings. the operator turns the winches handle, engaging the system to lift the top & bottom wings smoothly which are connected by steel wire rope. as the wing panels lifts, the adjustable manual jack at the base panel, are extended to provide additional support ensuring stability of the telescope structure. (ii) closing the wings. the operator when turns the winches handle in the opposite direction lowers the wing panels to closed position (see drg no 6). the adjustable manual jack can be gradually retracted to lower the base panel, ensuring controlled and smooth movement. (iii) the jack to be welded/bolted with base plate of size 300mm x 300mm x 10mm thick steel plate and the height of jack should be max of 6 openable. (iv) advantages: - (a) manual control - the winches system allow for precise manual control over the shutter movement. (ab) mechanical advantage - gears reduce the effort needed to lift or lower the wings. (ac) stable support - manual jacks provide strong and stable support for the base panel, ensuring safe and efficient operation. this mechanism of manual jack and winches system to ensure efficient, controlled, and fail safe operation of the wings. (f) tech staff of contractor to be present during assembling of shelter till its final taking over on charge by the insp team. (g) assembling and mounting of shelter on flat bed als to be provided by contractor as a onetime measure/initial demonstration till its final taking over on charge by the insp team. design criteria. (a) seismic co-efficient as per seismic zone iii. (b) wind load - equivalent to wind speed of 55 mtrs/sec as per is-875-2015 (reaff 2020). (c) roof slope -1:1.2. (d) external temperature (-) 10 0c to + 500c. (e) water absorption/penetration since, the shelter is removable and joints are not of permanent nature, flexibility in adoption of mechanism for sealing the joinery through appropriate means like silicon gel etc has been kept reserved for a later stage for optimum outcome during execution. however, the fwg mechanism would be adopted for sealing the joints. (i) rubber or silicon gaskets - rubber or silicon gaskets to be applied around the edges of the shelter panels and doors. it will be compressed to form a watertight and airtight seal when the shelter is assembled. (f) termite proofing all components of woods & puf to be treated for termite proofing. (g) ease of construction shelter should be modular in design. (h) design load as per is-875-2015 (reaff 2020)
Tender For repair and renovation of office rooms and corridor - providing and laying vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08 percentage and conforming to is 15622 , of approved brand & manufacturer , in all colours and shade , laid on 20 mm thick cement mortar 1 4 (1 cement 4 coarse sand) jointing with grey cement slurry 3.3 kg/sqm. the tiles must be cut with the zero chipping diamond cutter only . laying of tiles will be done with the notch trowel , plier , wedge , clips of required thickness , levelling system and rubber mallet for placing the tiles gently and easily. (i) glazed vitrified floor tiles polished finish of size of tile 600 x 600 mm , grouting the joints of flooring tiles having joint using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) , including filling / grouting and finishing complete as per direction of engineer-in-charge. (i)size of tile 600x600 mm , finishing walls with premium acrylic smooth interior paint with silicone additives of required shade , with water thinnable cement primer on wall surface having voc content less than 50 grams/litre , taking out existing wooden door shutter , repair by cutting , painting etc. and re-fixing of repaired door shutters to existing door frames , including replacement of hinges with screws , etc. as required , all complete as per the direction of the engineer-in-charge. , dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. (i) for thickness of tiles above 25 mm and up to 40 mm , marble polish (stone polish) (lumpsum)