Get complete information related to latest Reheater Coil Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reheater Coil Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reheater Coil Tenders.
Tender For supply of a set consist of 1) g 1/4 single solenoid valve with spring return ( g25 coil ) , qty - 02 nos , make - duncan , plasser or schrader only. 2) cylinder 4
Tender For corrigendum : supply of set of spares for ocb fitment work consist of three items: (i) stainless steel bolt with one nut , size m10 x 60x 40 tl, qty. 01set/set, (ii) stainless steel bolt with one nut, one s.s. flat washer & one s.s. spring washer. size : m 12 x 45 full threaded., qty. 01 set/set, (ii) s.s. wire netting coil, size id. 10 mm, od 20 mm, length 30 mm, qty. two nos, with two nos flat washer, size:m 11, qty. 01set/set. material : aisi31 6 (ss316), spec din-933, is 1364, is0 4017, property class a480. [ warranty period: 30 months after the date of delivery ]
Tender For supply of (1) trip coil 30 volt dc suitable for 11 kv vcb make bhel, 30 nos. (2) trip coil 30 volt dc suitable for 11 kv vcb make - stelmec, 30 nos. (3) trip coil 30 volt dc suitable for 11 kv vcb make - shree, 45 nos
Tender For corrigendum : supply of armature assembly , field coil assy 6 coil , drive assy , solenoid assy 24 volt , brush plate assy with screw , lock washer turm stud ce , nut washer fir field termind , screw for ce frame attach , screw for nose housing attach 5 nos , screw nose housing attach one , insulator for brush plate assy , washer field termind stud , insulation for field termind
Tender For corrigendum : tender for supply of supply of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexureiii-a , supply of cassette ac four way capacity 3 tr minimum 3 star rating inverter type rotary or scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of cassette ac four way capacity 4 tr rating inverter type rotary scroll compressor aircooled condensing unit with copper cooling coil refer annexure iii-a , supply of suitable size refrigerant grade copper piping for 2or2point5or3or 4tr cassette acorsplit ac unit refer annexureiii-a , providing flexible pvc duct hose covering pipeof size 60 mm suitable for exposed refrigerant pipes for cassttte ac units refer aneexure iii-a , providingcpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for refer annexureiii-a , providing cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexureiii-a , supply of rain proof outdoor duty as per ip-66 electrical control panel with incommer 4 pole mccb 100 amp digital voltmeter digital ammeter indication lamps refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 4 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor xlpeorpvc as directed by eic 4 core - 6 sqmm refer annexureiii-a , supply of following size lt power cable with copper conductor laying of the same in by eic 4core - 25 sqmm refer annexure-iii-a , supply of following size lt power cable with copper conductor as directed by eic 4core - 16 sqmm refer annexure-iii-a , supply of copper cable of size 4core - 2point5 sqmm for communication , supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness , supply of perforated hot dipped galvanised iron cable tray of size 300 mm width x 50 mm depth x 1point6 mm thickness , installation testing and commissioning of cassette ac four way capacity 2point5 tr minimum 3 star rating inverter type rotaryorscroll compressor aircooled refer annexure-iii-b , installationtesting and commissioning of cassette ac four way capacity 3 tr minimum 3 star rating inverter type refer annexure-iii-b , installation testing and commissioning of cassette ac four way capacity 4 tr inverter type rotary or scroll compressor units refer annexure-iii-b , erection testing and commissioning of suitable size refrigerant grade copper for 2or2point5or3or4tr cassette acorsplit ac unit refer annexure-iii-b , laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable refer annexure-iii-b , laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drain from the ac indoor units refer annexure-iii-b , laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation for condensate water drainrefer annexure-iii-b , erection testing and commissioning of rain proof outdoor duty as per ip-66 electrical control panel annexure-iii-b , laying of following size lt power cable with copper conductor xlpepvc insulation pvc inner sheathed armoured extruded pvc oas directed by eic 4 core - 4 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvc insulation as directed by eic 4 core - 6 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conducto as directed by eic 4 core - 25 sqmm refer annexure-iii-b , laying of following size lt power cable with copper conductor xlpeorpvcas directed by eic 4 core - 16 sqmm refer annexure-iii-b , laying of copper cable of size 4 core - 2point5 sqmm for communication , installing of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1point6 mm thickness